llvm-project/llvm/lib/Target/Hexagon/HexagonFixupHwLoops.cpp

196 lines
6.5 KiB
C++

//===---- HexagonFixupHwLoops.cpp - Fixup HW loops too far from LOOPn. ----===//
//
// The LLVM Compiler Infrastructure
//
// This file is distributed under the University of Illinois Open Source
// License. See LICENSE.TXT for details.
//
// The loop start address in the LOOPn instruction is encoded as a distance
// from the LOOPn instruction itself. If the start address is too far from
// the LOOPn instruction, the instruction needs to use a constant extender.
// This pass will identify and convert such LOOPn instructions to a proper
// form.
//===----------------------------------------------------------------------===//
#include "llvm/ADT/DenseMap.h"
#include "Hexagon.h"
#include "HexagonTargetMachine.h"
#include "llvm/CodeGen/MachineFunction.h"
#include "llvm/CodeGen/MachineFunctionPass.h"
#include "llvm/CodeGen/MachineInstrBuilder.h"
#include "llvm/CodeGen/Passes.h"
#include "llvm/PassSupport.h"
#include "llvm/Target/TargetInstrInfo.h"
using namespace llvm;
static cl::opt<unsigned> MaxLoopRange(
"hexagon-loop-range", cl::Hidden, cl::init(200),
cl::desc("Restrict range of loopN instructions (testing only)"));
namespace llvm {
FunctionPass *createHexagonFixupHwLoops();
void initializeHexagonFixupHwLoopsPass(PassRegistry&);
}
namespace {
struct HexagonFixupHwLoops : public MachineFunctionPass {
public:
static char ID;
HexagonFixupHwLoops() : MachineFunctionPass(ID) {
initializeHexagonFixupHwLoopsPass(*PassRegistry::getPassRegistry());
}
bool runOnMachineFunction(MachineFunction &MF) override;
MachineFunctionProperties getRequiredProperties() const override {
return MachineFunctionProperties().set(
MachineFunctionProperties::Property::AllVRegsAllocated);
}
const char *getPassName() const override {
return "Hexagon Hardware Loop Fixup";
}
void getAnalysisUsage(AnalysisUsage &AU) const override {
AU.setPreservesCFG();
MachineFunctionPass::getAnalysisUsage(AU);
}
private:
/// \brief Check the offset between each loop instruction and
/// the loop basic block to determine if we can use the LOOP instruction
/// or if we need to set the LC/SA registers explicitly.
bool fixupLoopInstrs(MachineFunction &MF);
/// \brief Replace loop instruction with the constant extended
/// version if the loop label is too far from the loop instruction.
void useExtLoopInstr(MachineFunction &MF,
MachineBasicBlock::iterator &MII);
};
char HexagonFixupHwLoops::ID = 0;
}
INITIALIZE_PASS(HexagonFixupHwLoops, "hwloopsfixup",
"Hexagon Hardware Loops Fixup", false, false)
FunctionPass *llvm::createHexagonFixupHwLoops() {
return new HexagonFixupHwLoops();
}
/// \brief Returns true if the instruction is a hardware loop instruction.
static bool isHardwareLoop(const MachineInstr *MI) {
return MI->getOpcode() == Hexagon::J2_loop0r ||
MI->getOpcode() == Hexagon::J2_loop0i ||
MI->getOpcode() == Hexagon::J2_loop1r ||
MI->getOpcode() == Hexagon::J2_loop1i;
}
bool HexagonFixupHwLoops::runOnMachineFunction(MachineFunction &MF) {
if (skipFunction(*MF.getFunction()))
return false;
return fixupLoopInstrs(MF);
}
/// \brief For Hexagon, if the loop label is to far from the
/// loop instruction then we need to set the LC0 and SA0 registers
/// explicitly instead of using LOOP(start,count). This function
/// checks the distance, and generates register assignments if needed.
///
/// This function makes two passes over the basic blocks. The first
/// pass computes the offset of the basic block from the start.
/// The second pass checks all the loop instructions.
bool HexagonFixupHwLoops::fixupLoopInstrs(MachineFunction &MF) {
// Offset of the current instruction from the start.
unsigned InstOffset = 0;
// Map for each basic block to it's first instruction.
DenseMap<const MachineBasicBlock *, unsigned> BlockToInstOffset;
const HexagonInstrInfo *HII =
static_cast<const HexagonInstrInfo *>(MF.getSubtarget().getInstrInfo());
// First pass - compute the offset of each basic block.
for (const MachineBasicBlock &MBB : MF) {
if (MBB.getAlignment()) {
// Although we don't know the exact layout of the final code, we need
// to account for alignment padding somehow. This heuristic pads each
// aligned basic block according to the alignment value.
int ByteAlign = (1u << MBB.getAlignment()) - 1;
InstOffset = (InstOffset + ByteAlign) & ~(ByteAlign);
}
BlockToInstOffset[&MBB] = InstOffset;
for (const MachineInstr &MI : MBB)
InstOffset += HII->getSize(&MI);
}
// Second pass - check each loop instruction to see if it needs to be
// converted.
InstOffset = 0;
bool Changed = false;
for (MachineBasicBlock &MBB : MF) {
InstOffset = BlockToInstOffset[&MBB];
// Loop over all the instructions.
MachineBasicBlock::iterator MII = MBB.begin();
MachineBasicBlock::iterator MIE = MBB.end();
while (MII != MIE) {
InstOffset += HII->getSize(&*MII);
if (MII->isDebugValue()) {
++MII;
continue;
}
if (isHardwareLoop(MII)) {
assert(MII->getOperand(0).isMBB() &&
"Expect a basic block as loop operand");
int diff = InstOffset - BlockToInstOffset[MII->getOperand(0).getMBB()];
if ((unsigned)abs(diff) > MaxLoopRange) {
useExtLoopInstr(MF, MII);
MII = MBB.erase(MII);
Changed = true;
} else {
++MII;
}
} else {
++MII;
}
}
}
return Changed;
}
/// \brief Replace loop instructions with the constant extended version.
void HexagonFixupHwLoops::useExtLoopInstr(MachineFunction &MF,
MachineBasicBlock::iterator &MII) {
const TargetInstrInfo *TII = MF.getSubtarget().getInstrInfo();
MachineBasicBlock *MBB = MII->getParent();
DebugLoc DL = MII->getDebugLoc();
MachineInstrBuilder MIB;
unsigned newOp;
switch (MII->getOpcode()) {
case Hexagon::J2_loop0r:
newOp = Hexagon::J2_loop0rext;
break;
case Hexagon::J2_loop0i:
newOp = Hexagon::J2_loop0iext;
break;
case Hexagon::J2_loop1r:
newOp = Hexagon::J2_loop1rext;
break;
case Hexagon::J2_loop1i:
newOp = Hexagon::J2_loop1iext;
break;
default:
llvm_unreachable("Invalid Hardware Loop Instruction.");
}
MIB = BuildMI(*MBB, MII, DL, TII->get(newOp));
for (unsigned i = 0; i < MII->getNumOperands(); ++i)
MIB.addOperand(MII->getOperand(i));
}