Every Analysis pass has a get method that returns a reference of the Result of
the Analysis, for example, BlockFrequencyInfo
&BlockFrequencyInfoWrapperPass::getBFI(). I believe that
ProfileSummaryInfo::getPSI() is the only exception to that, as it was returning
a pointer.
Another change is renaming isHotBB and isColdBB to isHotBlock and isColdBlock,
respectively. Most methods use BB as the argument of variable names while
methods usually refer to Basic Blocks as Blocks, instead of BB. For example,
Function::getEntryBlock, Loop:getExitBlock, etc.
I also fixed one of the comments.
Patch by Rodrigo Caetano Rocha!
Differential Revision: https://reviews.llvm.org/D54669
llvm-svn: 347182
Summary: For SamplePGO, we already record the callsite count in the call instruction itself. So we do not want to use BFI to get profile count as it is less accurate.
Reviewers: tejohnson, davidxl, eraman
Reviewed By: eraman
Subscribers: sanjoy, llvm-commits, mehdi_amini
Differential Revision: https://reviews.llvm.org/D36025
llvm-svn: 309964
clang-format (https://reviews.llvm.org/D33932) to keep primary headers
at the top and handle new utility headers like 'gmock' consistently with
other utility headers.
No other change was made. I did no manual edits, all of this is
clang-format.
This should allow other changes to have more clear and focused diffs,
and is especially motivated by moving some headers into more focused
libraries.
llvm-svn: 304786
ProfileSummaryInfo already checks whether the module has sample profile
in determining profile counts. This will also be useful in inliner to
clean up threshold updates.
llvm-svn: 303204
Summary:
Don't use the metadata on call instructions for determining hotness
unless we are in sample PGO mode, where it is needed because profile
counts are not accurate. In instrumentation mode this is not necessary
and does more harm than good when calls have VP metadata that hasn't
been properly scaled after transformations or dropped after constant
prop based devirtualization (both should be fixed, but we don't need
to do this in the first place for instrumentation PGO).
This required adjusting a number of tests to distinguish between sample
and instrumentation PGO handling, and to add in profile summary metadata
so that getProfileCount can get the summary.
Reviewers: davidxl, danielcdh
Subscribers: aemerson, rengolin, mehdi_amini, Prazek, llvm-commits
Differential Revision: https://reviews.llvm.org/D32877
llvm-svn: 302844
Summary: There is no need to check profile count as only CallInst will have metadata attached.
Reviewers: eraman
Reviewed By: eraman
Subscribers: llvm-commits
Differential Revision: https://reviews.llvm.org/D30799
llvm-svn: 297500
extractProfTotalWeight checks if the profile type is sample profile, but
before that we have to ensure that summary is available. Also expanded
the unittest to test the case where there is no summar
Differential Revision: https://reviews.llvm.org/D28708
llvm-svn: 291982
* Add is{Hot|Cold}CallSite methods
* Fix a bug in isHotBB where it was looking for MD_prof on a return instruction
* Use MD_prof data only if sample profiling was used to collect profiles.
* Add an unit test to ProfileSummaryInfo
Differential Revision: https://reviews.llvm.org/D28584
llvm-svn: 291878