The rematerialized instruction may require a more constrained register class
than the register being spilled. In the test case, the spilled register has been
inflated to the DPR register class, but we are rematerializing a load of the
ssub_0 sub-register which only exists for DPR_VFP2 registers.
The register class is reinflated after spilling, so the conservative choice is
only temporary.
llvm-svn: 128610