Commit Graph

2 Commits

Author SHA1 Message Date
Ulrich Weigand 9d980cbdb9 [PowerPC] Use true offset value in "memrix" machine operands
This is the second part of the change to always return "true"
offset values from getPreIndexedAddressParts, tackling the
case of "memrix" type operands.

This is about instructions like LD/STD that only have a 14-bit
field to encode immediate offsets, which are implicitly extended
by two zero bits by the machine, so that in effect we can access
16-bit offsets as long as they are a multiple of 4.

The PowerPC back end currently handles such instructions by
carrying the 14-bit value (as it will get encoded into the
actual machine instructions) in the machine operand fields
for such instructions.  This means that those values are
in fact not the true offset, but rather the offset divided
by 4 (and then truncated to an unsigned 14-bit value).

Like in the case fixed in r182012, this makes common code
operations on such offset values not work as expected.
Furthermore, there doesn't really appear to be any strong
reason why we should encode machine operands this way.

This patch therefore changes the encoding of "memrix" type
machine operands to simply contain the "true" offset value
as a signed immediate value, while enforcing the rules that
it must fit in a 16-bit signed value and must also be a
multiple of 4.

This change must be made simultaneously in all places that
access machine operands of this type.  However, just about
all those changes make the code simpler; in many cases we
can now just share the same code for memri and memrix
operands.

llvm-svn: 182032
2013-05-16 17:58:02 +00:00
Ulrich Weigand 7aa76b6a07 [PowerPC] Report true displacement value from getPreIndexedAddressParts
DAGCombiner::CombineToPreIndexedLoadStore calls a target routine to
decompose a memory address into a base/offset pair.  It expects the
offset (if constant) to be the true displacement value in order to
perform optional additional optimizations; in particular, to convert
other uses of the original pointer into uses of the new base pointer
after pre-increment.

The PowerPC implementation of getPreIndexedAddressParts, however,
simply calls SelectAddressRegImm, which returns a TargetConstant.
This value is appropriate for encoding into the instruction, but
it is not always usable as true displacement value:

- Its type is always MVT::i32, even on 64-bit, where addresses
  ought to be i64 ... this causes the optimization to simply
  always fail on 64-bit due to this line in DAGCombiner:

      // FIXME: In some cases, we can be smarter about this.
      if (Op1.getValueType() != Offset.getValueType()) {

- Its value is truncated to an unsigned 16-bit value if negative.
  This causes the above opimization to generate wrong code.

This patch fixes both problems by simply returning the true
displacement value (in its original type).  This doesn't
affect any other user of the displacement.

llvm-svn: 182012
2013-05-16 14:53:05 +00:00