Dave Bartolomeo 8ffce2ade3 Fix msc-version.c test to handle _MSC_VER=1910
Previously, VC++ has always set _MSC_VER to a four-digit value with the two least significant digits set to zero. Visual Studio 2017, however, sets _MSC_VER=1910, and we expect to update the least significant digit as we release major updates for VS 2017. This patch fixes the msc-version.c test to handle non-zero values in the two least significant digits of _MSC_VER.

llvm-svn: 296843
2017-03-03 00:08:55 +00:00
David L. Jones b4b88fdc75 Loosen checks for _MSC_FULL_VER under -fms-extensions.
Summary:
On actual Windows hosts :-) , this could report something other than the
fallback, with a non-zero minor/build number.

Reviewers: rnk, llvm-commits

Differential Revision: https://reviews.llvm.org/D27554

llvm-svn: 289011
2016-12-08 01:11:41 +00:00
David L. Jones 62cd86863a Add more tests for MSVC version handling.
Summary:
This change adds more test cases for the default MSVC compatibility version:
 1. When -fms-extensions is supplied, but -fmsc-version and
    -fms-compatibility-version are not.
 2. With the target triple specifies an MSVC environment, but no other
    -fms* flags.

Reviewers: rnk, llvm-commits

Subscribers: hans, compnerd, amccarth

Differential Revision: https://reviews.llvm.org/D27498

llvm-svn: 288997
2016-12-07 23:39:44 +00:00
Adrian McCarthy e4b26fc7a7 Get default -fms-compatibility-version from cl.exe's version
-fms-compatibility-version was defaulting to 18 (VS 2013), which is a pain if your environment is pointing to version 19 (VS 2015) libraries.

If cl.exe can be found, this patch uses its version number as the default instead. It re-uses the existing code to find the Visual Studio binaries folder and WinAPI methods to check its version. You can still explicitly specify a compatibility version on the command line. If you don't have cl.exe, this should be a no-op and you'll get the old default of 18.

This affected the tests, which assumed that if you didn't specific a version, that it would default to 18, but this won't be true for all machines. So a couple test cases had to be eliminated and a couple others had to be tweaked to allow for various outputs.

Addresses: https://llvm.org/bugs/show_bug.cgi?id=27215

Differential Revision: http://reviews.llvm.org/D20136

llvm-svn: 269515
2016-05-13 23:20:11 +00:00
David Majnemer c371ff048d MS ABI: Implement driver-level support for thread-safe statics
Decide whether or not to use thread-safe statics depending on whether or
not we have an explicit request from the driver.  If we don't have an
explicit request, infer which behavior to use depending on the
compatibility version we are targeting.

N.B. CodeGen support is still ongoing.

llvm-svn: 232906
2015-03-22 08:39:22 +00:00
Reid Kleckner c4da9c8e50 -fms-extensions: Bump the default _MSC_VER from 1700 to 1800, aka VS2013
VS 2013 is the minimum supported version, so it's reasonable for Clang
to simulate this by default. This also simplifies the clang-cl
self-host, since we have the 18.00 version check.

llvm-svn: 230243
2015-02-23 19:25:48 +00:00
Saleem Abdulrasool c68237bc2c Driver: bifurcate extended and basic MSC versioning
This restores the original behaviour of -fmsc-version. The older option
remains as a mechanism for specifying the basic version information. A
secondary option, -fms-compatibility-version permits the user to specify an
extended version to the driver.

The new version takes the value as a dot-separated value rather than the
major * 100 + minor format that -fmsc-version format. This makes it easier to
specify the value as well as a more flexible manner for specifying the value.

Specifying both values is considered an error.

The older parameter is left solely as a driver option, which is normalised into
the newer parameter. This allows us to retain a single code path in the
compiler itself whilst preserving the semantics of the old parameter as well as
avoid having to determine which of two formats are being used by the invocation.

The test changes are due to the fact that the compiler no longer supports the
old option, and is a direct conversion to the new option.

llvm-svn: 213119
2014-07-16 03:13:50 +00:00
Saleem Abdulrasool f7062b2313 Driver: correct behaviour of -fmsc-version=MAJOR
Ensure that we properly handle the case where just the major version component
is provided by the user.

Thanks to Alp Toker for pointing out that this was not handled correctly!

llvm-svn: 211506
2014-06-23 17:36:36 +00:00
Saleem Abdulrasool 9d45e77dca Driver: enhance MSC version compatibility
The version information for Visual Studio is spread over multiple variables.
The newer Windows SDK has started making use of some of the extended versioning
variables that were previously undefined.  Enhance our compatibility definitions
for these cases.

_MSC_VER is defined to be the Major * 100 + Minor.  _MSC_FULL_VER is defined to
be Major * 10000000 + Minor * 100000 + Build.  And _MSC_BUILD is the build
revision of the compiler.

Extend the -fmsc-version option in a compatible manner.  If the value is the
previous form of MMmm, then we assume that the build number is 0.  Otherwise, a
specific build number may be passed by using the form MMmmbbbbb.  Due to
bitwidth limitations of the option, it is currently not possible to define a
revision value.

The version information can be passed as either the decimal encoded value
(_MSC_FULL_VER or _MSC_VER) or as a dot-delimited value.

The change to the TextDiagnostic is to deal with the updated encoding of the
version information.

llvm-svn: 211420
2014-06-20 22:58:35 +00:00