forked from OSchip/llvm-project
Once we've emitted a fatal diagnostic, keep counting errors but with a
separate count of "suppressed" errors. This way, semantic analysis bits that depend on the error count to determine whether problems occured (e.g., some template argument deduction failures, jump-scope checking) will not get confused. The actual problem here is that a missing #include (which is a fatal error) could cause the jump-scope checker to run on invalid code, which it is not prepared to do. Trivial fix for both <rdar://problem/7775941> and <rdar://problem/7775709>. llvm-svn: 101297
This commit is contained in:
parent
99bfbca6ec
commit
2d2d90750c
|
@ -214,7 +214,8 @@ private:
|
|||
|
||||
unsigned NumWarnings; // Number of warnings reported
|
||||
unsigned NumErrors; // Number of errors reported
|
||||
|
||||
unsigned NumErrorsSuppressed; // Number of errors suppressed
|
||||
|
||||
/// CustomDiagInfo - Information for uniquing and looking up custom diags.
|
||||
diag::CustomDiagInfo *CustomDiagInfo;
|
||||
|
||||
|
@ -343,6 +344,7 @@ public:
|
|||
bool hasFatalErrorOccurred() const { return FatalErrorOccurred; }
|
||||
|
||||
unsigned getNumErrors() const { return NumErrors; }
|
||||
unsigned getNumErrorsSuppressed() const { return NumErrorsSuppressed; }
|
||||
unsigned getNumWarnings() const { return NumWarnings; }
|
||||
|
||||
/// getCustomDiagID - Return an ID for a diagnostic with the specified message
|
||||
|
|
|
@ -227,6 +227,7 @@ Diagnostic::Diagnostic(DiagnosticClient *client) : Client(client) {
|
|||
|
||||
NumWarnings = 0;
|
||||
NumErrors = 0;
|
||||
NumErrorsSuppressed = 0;
|
||||
CustomDiagInfo = 0;
|
||||
CurDiagID = ~0U;
|
||||
LastDiagLevel = Ignored;
|
||||
|
@ -537,8 +538,14 @@ bool Diagnostic::ProcessDiag() {
|
|||
|
||||
// If a fatal error has already been emitted, silence all subsequent
|
||||
// diagnostics.
|
||||
if (FatalErrorOccurred)
|
||||
if (FatalErrorOccurred) {
|
||||
if (DiagLevel >= Diagnostic::Error) {
|
||||
++NumErrors;
|
||||
++NumErrorsSuppressed;
|
||||
}
|
||||
|
||||
return false;
|
||||
}
|
||||
|
||||
// If the client doesn't care about this message, don't issue it. If this is
|
||||
// a note and the last real diagnostic was ignored, ignore it too.
|
||||
|
|
|
@ -515,7 +515,8 @@ bool CompilerInstance::ExecuteAction(FrontendAction &Act) {
|
|||
|
||||
if (getDiagnosticOpts().ShowCarets) {
|
||||
unsigned NumWarnings = getDiagnostics().getNumWarnings();
|
||||
unsigned NumErrors = getDiagnostics().getNumErrors();
|
||||
unsigned NumErrors = getDiagnostics().getNumErrors() -
|
||||
getDiagnostics().getNumErrorsSuppressed();
|
||||
|
||||
if (NumWarnings)
|
||||
OS << NumWarnings << " warning" << (NumWarnings == 1 ? "" : "s");
|
||||
|
|
|
@ -0,0 +1,9 @@
|
|||
// RUN: %clang_cc1 -fsyntax-only -verify %s
|
||||
|
||||
#include "not exist" // expected-error{{'not exist' file not found}}
|
||||
|
||||
class AnalysisContext {};
|
||||
static ControlFlowKind CheckFallThrough(AnalysisContext &AC) {
|
||||
if (const AsmStmt *AS = dyn_cast<AsmStmt>(S)) {}
|
||||
bool NoReturnEdge = false;
|
||||
}
|
Loading…
Reference in New Issue