forked from OSchip/llvm-project
Fix TestMiniDumpNew.py test for Python 2/3 issue
On Windows, where we use Python 3 for testing, we have to be more explicit about converting between binary and string representations. I believe this should still work for Python 2, but I don't have a convenient way to try it out. Differential Revision: https://reviews.llvm.org/D26643 llvm-svn: 286909
This commit is contained in:
parent
7b26dbb125
commit
18270a843a
|
@ -108,15 +108,16 @@ class MiniDumpNewTestCase(TestBase):
|
|||
/proc/PID/status which is written in the file
|
||||
"""
|
||||
shutil.copyfile(core, newcore)
|
||||
with open(newcore, "r+") as f:
|
||||
with open(newcore, "rb+") as f:
|
||||
f.seek(offset)
|
||||
self.assertEqual(f.read(5), oldpid)
|
||||
currentpid = f.read(5).decode('utf-8')
|
||||
self.assertEqual(currentpid, oldpid)
|
||||
|
||||
f.seek(offset)
|
||||
if len(newpid) < len(oldpid):
|
||||
newpid += " " * (len(oldpid) - len(newpid))
|
||||
newpid += "\n"
|
||||
f.write(newpid)
|
||||
f.write(newpid.encode('utf-8'))
|
||||
|
||||
def test_deeper_stack_in_minidump_with_same_pid_running(self):
|
||||
"""Test that we read the information from the core correctly even if we
|
||||
|
|
Loading…