lammps/doc/bond_harmonic.txt

48 lines
1.1 KiB
Plaintext

"LAMMPS WWW Site"_lws - "LAMMPS Documentation"_ld - "LAMMPS Commands"_lc :c
:link(lws,http://lammps.sandia.gov)
:link(ld,Manual.html)
:link(lc,Section_commands.html#comm)
:line
bond_style harmonic command :h3
[Syntax:]
bond_style harmonic :pre
[Examples:]
bond_style harmonic
bond_coeff 5 80.0 1.2 :pre
[Description:]
The {harmonic} bond style uses the potential
:c,image(Eqs/bond_harmonic.jpg)
where r0 is the equilibrium bond distance. Note that the usual 1/2
factor is included in K.
The following coefficients must be defined for each bond type via the
"bond_coeff"_bond_coeff.html command as in the example above, or in
the data file or restart files read by the "read_data"_read_data.html
or "read_restart"_read_restart.html commands:
K (energy/distance^2)
r0 (distance) :ul
[Restrictions:]
This bond style can only be used if LAMMPS was built with the
"molecular" package (which it is by default). See the "Making
LAMMPS"_Section_start.html#2_3 section for more info on packages.
[Related commands:]
"bond_coeff"_bond_coeff.html, "delete_bonds"_delete_bonds.html
[Default:] none