forked from lijiext/lammps
164 lines
7.1 KiB
HTML
164 lines
7.1 KiB
HTML
<HTML>
|
|
<CENTER><A HREF = "http://lammps.sandia.gov">LAMMPS WWW Site</A> - <A HREF = "Manual.html">LAMMPS Documentation</A> - <A HREF = "Section_commands.html#comm">LAMMPS Commands</A>
|
|
</CENTER>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<HR>
|
|
|
|
<H3>fix nvt/sphere command
|
|
</H3>
|
|
<P><B>Syntax:</B>
|
|
</P>
|
|
<PRE>fix ID group-ID nvt/sphere Tstart Tstop Tdamp keyword value ...
|
|
</PRE>
|
|
<UL><LI>ID, group-ID are documented in <A HREF = "fix.html">fix</A> command
|
|
|
|
<LI>nvt/sphere = style name of this fix command
|
|
|
|
<LI>Tstart,Tstop = desired temperature at start/end of run
|
|
|
|
<LI>Tdamp = temperature damping parameter (time units)
|
|
|
|
<LI>zero or more keyword/value pairs may be appended
|
|
|
|
<LI>keyword = <I>drag</I>
|
|
|
|
<PRE> <I>drag</I> value = drag factor added to thermostat (0.0 = no drag)
|
|
</PRE>
|
|
|
|
</UL>
|
|
<P><B>Examples:</B>
|
|
</P>
|
|
<PRE>fix 1 all nvt/sphere 300.0 300.0 100.0
|
|
fix 1 all nvt/sphere 300.0 300.0 100.0 drag 0.2
|
|
</PRE>
|
|
<P><B>Description:</B>
|
|
</P>
|
|
<P>Perform constant NVT integration to update position, velocity, and
|
|
angular velocity each timestep for extended spherical particles in the
|
|
group using a Nose/Hoover temperature thermostat. V is volume; T is
|
|
temperature. This creates a system trajectory consistent with the
|
|
canonical ensemble.
|
|
</P>
|
|
<P>This fix differs from the <A HREF = "fix_nvt.html">fix nvt</A> command, which
|
|
assumes point particles and only updates their position and velocity.
|
|
</P>
|
|
<P>The thermostat is applied to both the translational and rotational
|
|
degrees of freedom for the spherical particles, assuming a compute is
|
|
used which calculates a temperature that includes the rotational
|
|
degrees of freedom (see below). The translational degrees of freedom
|
|
can also have a bias velocity removed from them before thermostatting
|
|
takes place; see the description below.
|
|
</P>
|
|
<P>The desired temperature at each timestep is a ramped value during the
|
|
run from <I>Tstart</I> to <I>Tstop</I>. The <I>Tdamp</I> parameter is specified in
|
|
time units and determines how rapidly the temperature is relaxed. For
|
|
example, a value of 100.0 means to relax the temperature in a timespan
|
|
of (roughly) 100 time units (tau or fmsec or psec - see the
|
|
<A HREF = "units.html">units</A> command).
|
|
</P>
|
|
<P>In some cases (e.g. for solids) the temperature of the system can
|
|
oscillate undesirably when a Nose/Hoover thermostat is applied. The
|
|
optional <I>drag</I> keyword will damp these oscillations, although it
|
|
alters the Nose/Hoover equations. A value of 0.0 (no drag) leaves the
|
|
Nose/Hoover formalism unchanged. A non-zero value adds a drag term;
|
|
the larger the value specified, the greater the damping effect.
|
|
Performing a short run and monitoring the temperature is the best way
|
|
to determine if the drag term is working. Typically a value between
|
|
0.2 to 2.0 is sufficient to damp oscillations after a few periods.
|
|
</P>
|
|
<P>This fix computes a temperature each timestep. To do this, the fix
|
|
creates its own compute of style "temp/sphere", as if this command
|
|
had been issued:
|
|
</P>
|
|
<PRE>compute fix-ID_temp group-ID temp/sphere
|
|
</PRE>
|
|
<P>See the <A HREF = "compute_temp_sphere.html">compute temp/sphere</A> command for
|
|
details. Note that the ID of the new compute is the fix-ID +
|
|
underscore + "temp", and the group for the new compute is the same as
|
|
the fix group.
|
|
</P>
|
|
<P>Note that this is NOT the compute used by thermodynamic output (see
|
|
the <A HREF = "thermo_style.html">thermo_style</A> command) with ID = <I>thermo_temp</I>.
|
|
This means you can change the attributes of this fix's temperature
|
|
(e.g. its degrees-of-freedom) via the
|
|
<A HREF = "compute_modify.html">compute_modify</A> command or print this temperature
|
|
during thermodynamic output via the <A HREF = "thermo_style.html">thermo_style
|
|
custom</A> command using the appropriate compute-ID.
|
|
It also means that changing attributes of <I>thermo_temp</I> will have no
|
|
effect on this fix.
|
|
</P>
|
|
<P>Like other fixes that perform thermostatting, this fix can be used
|
|
with <A HREF = "compute.html">compute commands</A> that calculate a temperature
|
|
after removing a "bias" from the atom velocities. E.g. removing the
|
|
center-of-mass velocity from a group of atoms or only calculating
|
|
temperature on the x-component of velocity or only calculating
|
|
temperature for atoms in a geometric region. This is not done by
|
|
default, but only if the <A HREF = "fix_modify.html">fix_modify</A> command is used
|
|
to assign a temperature compute to this fix that includes such a bias
|
|
term. See the doc pages for individual <A HREF = "compute.html">compute
|
|
commands</A> to determine which ones include a bias. In
|
|
this case, the thermostat works in the following manner: the current
|
|
temperature is calculated taking the bias into account, bias is
|
|
removed from each atom, thermostatting is performed on the remaining
|
|
thermal degrees of freedom, and the bias is added back in.
|
|
</P>
|
|
<P><B>Restart, fix_modify, output, run start/stop, minimize info:</B>
|
|
</P>
|
|
<P>This fix writes the state of the Nose/Hoover thermostat to <A HREF = "restart.html">binary
|
|
restart files</A>. See the <A HREF = "read_restart.html">read_restart</A>
|
|
command for info on how to re-specify a fix in an input script that
|
|
reads a restart file, so that the operation of the fix continues in an
|
|
uninterrupted fashion.
|
|
</P>
|
|
<P>The <A HREF = "fix_modify.html">fix_modify</A> <I>temp</I> option is supported by this
|
|
fix. You can use it to assign a <A HREF = "compute.html">compute</A> you have
|
|
defined to this fix which will be used in its thermostatting
|
|
procedure.
|
|
</P>
|
|
<P>The <A HREF = "fix_modify.html">fix_modify</A> <I>energy</I> option is supported by this
|
|
fix to add the energy change induced by Nose/Hoover thermostatting to
|
|
the system's potential energy as part of <A HREF = "thermo_style.html">thermodynamic
|
|
output</A>.
|
|
</P>
|
|
<P>The cummulative energy change due to this fix is stored as a scalar
|
|
quantity, which can be accessed by various <A HREF = "Section_howto.html#4_15">output
|
|
commands</A>. The scalar value calculated by
|
|
this fix is "extensive", meaning it scales with the number of atoms in
|
|
the simulation.
|
|
</P>
|
|
<P>This fix can ramp its target temperature over multiple runs, using the
|
|
<I>start</I> and <I>stop</I> keywords of the <A HREF = "run.html">run</A> command. See the
|
|
<A HREF = "run.html">run</A> command for details of how to do this.
|
|
</P>
|
|
<P>This fix is not invoked during <A HREF = "minimize.html">energy minimization</A>.
|
|
</P>
|
|
<P><B>Restrictions:</B>
|
|
</P>
|
|
<P>This fix requires that atoms store torque and angular velocity (omega)
|
|
as defined by the <A HREF = "atom_style.html">atom_style</A>. It also require they
|
|
store either a per-particle radius or per-type <A HREF = "shape.html">shape</A>.
|
|
</P>
|
|
<P>All particles in the group must be finite-size spheres. They cannot
|
|
be point particles, nor can they be aspherical.
|
|
</P>
|
|
<P>The final Tstop cannot be 0.0 since it would make the target T = 0.0
|
|
at some timestep during the simulation which is not allowed in
|
|
the Nose/Hoover formulation.
|
|
</P>
|
|
<P><B>Related commands:</B>
|
|
</P>
|
|
<P><A HREF = "fix_nvt.html">fix nvt</A>, <A HREF = "fix_nve_sphere.html">fix nve_sphere</A>, <A HREF = "fix_nvt_asphere.html">fix
|
|
nvt_asphere</A>, <A HREF = "fix_npt_sphere.html">fix
|
|
npt_sphere</A>, <A HREF = "fix_modify.html">fix_modify</A>
|
|
</P>
|
|
<P><B>Default:</B>
|
|
</P>
|
|
<P>The keyword defaults are drag = 0.0.
|
|
</P>
|
|
</HTML>
|