<HTML>
|
|
<CENTER><A HREF = "http://lammps.sandia.gov">LAMMPS WWW Site</A> - <A HREF = "Manual.html">LAMMPS Documentation</A> - <A HREF = "Section_commands.html#comm">LAMMPS Commands</A>
|
|
</CENTER>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<HR>
|
|
|
|
<H3>fix box/relax command
|
|
</H3>
|
|
<P><B>Syntax:</B>
|
|
</P>
|
|
<PRE>fix ID group-ID box/relax style args keyword value ...
|
|
</PRE>
|
|
<UL><LI>ID, group-ID are documented in <A HREF = "fix.html">fix</A> command
|
|
|
|
<LI>box/relax = style name of this fix command
|
|
|
|
<LI>style = <I>xyz</I> or <I>xy</I> or <I>yz</I> or <I>xz</I> or <I>aniso</I>
|
|
|
|
<PRE> <I>xyz</I> arg = P = desired pressure (pressure units)
|
|
<I>xy</I> or <I>yz</I> or <I>xz</I> or <I>aniso</I> args = Px Py Pz
|
|
Px,Py,Pz = desired pressure in x,y,z (pressure units)
|
|
</PRE>
|
|
<LI>zero or more keyword/value pairs may be appended to the args
|
|
|
|
<LI>keyword = <I>dilate</I> or <I>vmax</I>
|
|
|
|
<PRE> <I>dilate</I> value = <I>all</I> or <I>partial</I>
|
|
<I>vmax</I> value = fraction = max allowed volume change in one iteration
|
|
</PRE>
|
|
|
|
</UL>
|
|
<P><B>Examples:</B>
|
|
</P>
|
|
<PRE>fix 1 all box/relax xyz 0.0 vmax 0.001
|
|
fix 2 water box/relax aniso 0.0 0.0 1000.0 dilate partial
|
|
</PRE>
|
|
<P><B>Description:</B>
|
|
</P>
|
|
<P>Apply a pressure to the simulation box during an <A HREF = "minimize.html">energy
|
|
minimization</A>. This allows the box dimensions to vary
|
|
during the iterations of the minimizer so that the final configuration
|
|
will be both an energy minimum for the potential energy of the atoms
|
|
and the system pressure will be close to the desired pressure.
|
|
Conceptually, specifying a positive pressure is like squeezing on the
|
|
simulation box; a negative pressure typically allows the box to
|
|
expand.
|
|
</P>
|
|
<P>The pressure can be specified in one of several styles, as determined
|
|
by the <I>style</I> argument.
|
|
</P>
|
|
<P>Style <I>xyz</I> means couple all 3 dimensions together when pressure is
|
|
computed (isotropic pressure), and dilate/contract the 3 dimensions
|
|
together. Styles <I>xy</I> or <I>yz</I> or <I>xz</I> means that the 2 specified
|
|
dimensions are coupled together, both for pressure computation and for
|
|
dilation/contraction. The 3rd dimension dilates/contracts
|
|
independently according to its specified pressure. For style <I>aniso</I>,
|
|
all 3 dimensions dilate/contract independently according to the 3
|
|
specified pressure values.
|
|
</P>
|
|
<P>For any of the styles except <I>xyz</I>, the target pressure for any
|
|
independent components (e.g. z in <I>xy</I>, or any dimension in <I>aniso</I>)
|
|
can be specified as NULL. This means that no pressure is applied to
|
|
that dimension so that the box dimension remains unchanged during the
|
|
minimization.
|
|
</P>
|
|
<P>For styles <I>xy</I> and <I>yz</I> and <I>xz</I>, the target pressures must be the
|
|
same for the two coupled dimensions and cannot be specified as NULL.
|
|
</P>
|
|
<P>For all pressure styles, the simulation box stays rectangular in
|
|
shape. Tilted boxes (triclinic symmetry) are supported by other
|
|
LAMMPS commands (see <A HREF = "Section_howto.html#4_12">this section</A> of the
|
|
manual), but not yet by this command.
|
|
</P>
|
|
<P>When the size of the simulation box changes, all atoms are re-scaled
|
|
to new positions, unless the keyword <I>dilate</I> is specified with a
|
|
value of <I>partial</I>, in which case only the atoms in the fix group are
|
|
re-scaled. This can be useful for leaving the coordinates of atoms in
|
|
a solid substrate unchanged and controlling the pressure of a
|
|
surrounding fluid.
|
|
</P>
|
|
<P>The <I>vmax</I> keyword can be used to limit the fractional change in the
|
|
volume of the simulation box that can occur in one iteration of the
|
|
minimizer. If the pressure is not settling down during the
|
|
minimization this can be because the volume is fluctuating too much.
|
|
The specfied fraction must be greater than 0.0 and should be << 1.0.
|
|
A value of 0.001 means the volume cannot change by more than 1/10 of a
|
|
percent in one iteration for style <I>xyz</I>. For the other styles it
|
|
means no linear dimension of the simulation box can change by more
|
|
than 1/10 of a percent.
|
|
</P>
|
|
<P>IMPORTANT NOTE: As normally computed, pressure includes a kinetic-
|
|
energy or temperature-dependent component; see the <A HREF = "compute_pressure.html">compute
|
|
pressure</A> command. However, atom velocities are
|
|
ignored during a minimization, and the applied pressure(s) specified
|
|
with this command are assumed to only be the virial component of the
|
|
pressure (the non-kinetic portion). Thus if atoms have a non-zero
|
|
temperature and you print the usual thermodynamic pressure, it may not
|
|
appear the system is converging to your specified pressure. The
|
|
solution for this is to either (a) zero the velocities of all atoms
|
|
before performing the minimization, or (b) make sure you are
|
|
monitoring the pressure without its kinetic component. The latter
|
|
can be done by outputting the pressure from the fix this command
|
|
creates (see below) or a pressure fix you define yourself.
|
|
</P>
|
|
<P>IMPORTANT NOTE: Because pressure is often a very sensitive function of
|
|
volume, it can be difficult for the minimizer to equilibrate the
|
|
system the desired pressure with high precision. Some techiniques
|
|
that seem to help are (a) use the "min_modify line quadratic" option
|
|
when minimizing with box relaxtions, and (b) minimize several times in
|
|
succession if need be, to drive the pressure closer to the target
|
|
pressure. Also note that some systems (e.g. liquids) will not sustain
|
|
an anisotropic applied pressure, which means the minimizer will not
|
|
converge.
|
|
</P>
|
|
<HR>
|
|
|
|
<P>This fix computes a temperature and pressure each timestep. The
|
|
temperature is used to compute the kinetic contribution to the
|
|
pressure, even though this is subsequently ignored by default. To do
|
|
this, the fix creates its own computes of style "temp" and "pressure",
|
|
as if these commands had been issued:
|
|
</P>
|
|
<PRE>compute fix-ID_temp group-ID temp
|
|
compute fix-ID_press group-ID pressure fix-ID_temp virial
|
|
</PRE>
|
|
<P>See the <A HREF = "compute_temp.html">compute temp</A> and <A HREF = "compute_pressure.html">compute
|
|
pressure</A> commands for details. Note that the
|
|
IDs of the new computes are the fix-ID + underscore + "temp" or fix_ID
|
|
+ underscore + "press", and the group for the new computes is the same
|
|
as the fix group. Also note that the pressure compute does not
|
|
include a kinetic component.
|
|
</P>
|
|
<P>Note that these are NOT the computes used by thermodynamic output (see
|
|
the <A HREF = "thermo_style.html">thermo_style</A> command) with ID = <I>thermo_temp</I>
|
|
and <I>thermo_press</I>. This means you can change the attributes of this
|
|
fix's temperature or pressure via the
|
|
<A HREF = "compute_modify.html">compute_modify</A> command or print this temperature
|
|
or pressure during thermodynamic output via the <A HREF = "thermo_style.html">thermo_style
|
|
custom</A> command using the appropriate compute-ID.
|
|
It also means that changing attributes of <I>thermo_temp</I> or
|
|
<I>thermo_press</I> will have no effect on this fix.
|
|
</P>
|
|
<HR>
|
|
|
|
<P><B>Restart, fix_modify, output, run start/stop, minimize info:</B>
|
|
</P>
|
|
<P>No information about this fix is written to <A HREF = "restart.html">binary restart
|
|
files</A>.
|
|
</P>
|
|
<P>The <A HREF = "fix_modify.html">fix_modify</A> <I>temp</I> and <I>press</I> options are
|
|
supported by this fix. You can use them to assign a
|
|
<A HREF = "compute.html">compute</A> you have defined to this fix which will be used
|
|
in its temperature and pressure calculation, as described above. Note
|
|
that as described above, if you assign a pressure compute to this fix
|
|
that includes a kinetic energy component it will affect the
|
|
minimization, most likely in an undesirable way.
|
|
</P>
|
|
<P>IMPORTANT NOTE: If both the <I>temp</I> and <I>press</I> keywords are used in a
|
|
single thermo_modify command (or in two separate commands), then the
|
|
order in which the keywords are specified is important. Note that a
|
|
<A HREF = "compute_pressure.html">pressure compute</A> defines its own temperature
|
|
compute as an argument when it is specified. The <I>temp</I> keyword will
|
|
override this (for the pressure compute being used by fix npt), but
|
|
only if the <I>temp</I> keyword comes after the <I>press</I> keyword. If the
|
|
<I>temp</I> keyword comes before the <I>press</I> keyword, then the new pressure
|
|
compute specified by the <I>press</I> keyword will be unaffected by the
|
|
<I>temp</I> setting.
|
|
</P>
|
|
<P>No global scalar or vector or per-atom quantities are stored by this
|
|
fix for access by various <A HREF = "Section_howto.html#4_15">output commands</A>.
|
|
No parameter of this fix can be used with the <I>start/stop</I> keywords of
|
|
the <A HREF = "run.html">run</A> command.
|
|
</P>
|
|
<P>This fix is invoked during <A HREF = "minimize.html">energy minimization</A>, but
|
|
not for the purpose of adding a contribution to the energy or forces
|
|
being minimized. Instead it alters the simulation box geometry as
|
|
described above.
|
|
</P>
|
|
<P><B>Restrictions:</B>
|
|
</P>
|
|
<P>Any box dimension adjusted by this fix must be periodic. A dimension
|
|
whose target pressure is specified as NULL can be non-periodic or
|
|
periodic.
|
|
</P>
|
|
<P><B>Related commands:</B>
|
|
</P>
|
|
<P><A HREF = "fix_nph.html">fix npt</A>, <A HREF = "minimize.html">minimize</A>
|
|
</P>
|
|
<P><B>Default:</B>
|
|
</P>
|
|
<P>The keyword defaults are dilate = all and vmax = 0.0001.
|
|