<HTML>
|
|
<CENTER><A HREF = "http://lammps.sandia.gov">LAMMPS WWW Site</A> - <A HREF = "Manual.html">LAMMPS Documentation</A> - <A HREF = "Section_commands.html#comm">LAMMPS Commands</A>
|
|
</CENTER>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<HR>
|
|
|
|
<H3>dielectric command
|
|
</H3>
|
|
<P><B>Syntax:</B>
|
|
</P>
|
|
<PRE>dielectric value
|
|
</PRE>
|
|
<UL><LI>value = dielectric constant
|
|
</UL>
|
|
<P><B>Examples:</B>
|
|
</P>
|
|
<PRE>dielectric 2.0
|
|
</PRE>
|
|
<P><B>Description:</B>
|
|
</P>
|
|
<P>Set the dielectric constant for Coulombic interactions (pairwise and
|
|
long-range) to this value. The constant is unitless, since it is used
|
|
to reduce the strength of the interactions. The value is used in the
|
|
denominator of the formulas for Coulombic interactions - e.g. a value
|
|
of 4.0 reduces the Coulombic interactions to 25% of their default
|
|
strength. See the <A HREF = "pair_style.html">pair_style</A> command for more
|
|
details.
|
|
</P>
|
|
<P><B>Restrictions:</B> none
|
|
</P>
|
|
<P><B>Related commands:</B>
|
|
</P>
|
|
<P><A HREF = "pair_style.html">pair_style</A>
|
|
</P>
|
|
<P><B>Default:</B>
|
|
</P>
|
|
<PRE>dielectric 1.0
|
|
</PRE>
|
|
</HTML>
|