lammps/doc/change_box.txt

333 lines
15 KiB
Plaintext

"LAMMPS WWW Site"_lws - "LAMMPS Documentation"_ld - "LAMMPS Commands"_lc :c
:link(lws,http://lammps.sandia.gov)
:link(ld,Manual.html)
:link(lc,Section_commands.html#comm)
:line
change_box command :h3
[Syntax:]
change_box group-ID parameter args ... keyword args ... :pre
group-ID = ID of group of atoms to (optionally) displace :ulb,l
one or more parameter/arg pairs may be appended :l
parameter = {x} or {y} or {z} or {xy} or {xz} or {yz} or {boundary} or {ortho} or {triclinic} or {set} or {remap}
{x}, {y}, {z} args = style value(s)
style = {final} or {delta} or {scale} or {volume}
{final} values = lo hi
lo hi = box boundaries after displacement (distance units)
{delta} values = dlo dhi
dlo dhi = change in box boundaries after displacement (distance units)
{scale} values = factor
factor = multiplicative factor for change in box length after displacement
{volume} value = none = adjust this dim to preserve volume of system
{xy}, {xz}, {yz} args = style value
style = {final} or {delta}
{final} value = tilt
tilt = tilt factor after displacement (distance units)
{delta} value = dtilt
dtilt = change in tilt factor after displacement (distance units)
{boundary} args = x y z
x,y,z = {p} or {s} or {f} or {m}, one or two letters
{p} is periodic
{f} is non-periodic and fixed
{s} is non-periodic and shrink-wrapped
{m} is non-periodic and shrink-wrapped with a minimum value
{ortho} args = none = change box to orthogonal
{triclinic} args = none = change box to triclinic
{set} args = none = store state of current box
{remap} args = none = remap atom coords from last saved state to current box :pre
zero or more keyword/value pairs may be appended :l
keyword = {units} :l
{units} value = {lattice} or {box}
lattice = distances are defined in lattice units
box = distances are defined in simulation box units :pre
:ule
[Examples:]
change_box all xy final -2.0 z final 0.0 5.0 boundary p p f remap units box
change_box all x scale 1.1 y volume z volume remap :pre
[Description:]
Change the volume and/or shape and/or boundary conditions for the
simulation box. Orthogonal simulation boxes have 3 adjustable size
parameters (x,y,z). Triclinic (non-orthogonal) simulation boxes have
6 adjustable size/shape parameters (x,y,z,xy,xz,yz). Any or all of
them can be adjusted independently by this command. Thus it can be
used to expand or contract a box, or to apply a shear strain to a
non-orthogonal box. It can also be used to change the boundary
conditions for the simulation box, similar to the
"boundary"_boundary.html command.
The size and shape of the initial simulation box are specified by the
"create_box"_create_box.html or "read_data"_read_data.html or
"read_restart"_read_restart.html command used to setup the simulation.
The size and shape may be altered by subsequent runs, e.g. by use of
the "fix npt"_fix_nh.html or "fix deform"_fix_deform.html commands.
The "create_box"_create_box.html, "read data"_read_data.html, and
"read_restart"_read_restart.html commands also determine whether the
simulation box is orthogonal or triclinic and their doc pages explain
the meaning of the xy,xz,yz tilt factors.
See "Section_howto 12"_Section_howto.html#howto_12 of the doc pages
for a geometric description of triclinic boxes, as defined by LAMMPS,
and how to transform these parameters to and from other commonly used
triclinic representations.
The keywords used in this command are applied sequentially to the
simulation box and the atoms in it, in the order specified.
Before the sequence of keywords are invoked, the current box
size/shape is stored, in case a {remap} keyword is used to map the
atom coordinates from a previously stored box size/shape to the
current one.
After all the keywords have been processed, any shrink-wrap boundary
conditions are invoked (see the "boundary"_boundary.html command)
which may change simulation box boundaries, and atoms are migrated to
new owning processors.
IMPORTANT_NOTE: This means that you cannot use the change_box command
to enlarge a shrink-wrapped box, e.g. to make room to insert more
atoms via the "create_atoms"_create_atoms.html command, because the
simulation box will be re-shrink-wrapped before the change_box command
completes. Instead you could do something like this, assuming the
simulation box is non-periodic and atoms extend from 0 to 20 in all
dimensions:
change_box all x final -10 20
create_atoms 1 single -5 5 5 # this will fail to insert an atom :pre
change_box all x final -10 20 boundary f s s
create_atoms 1 single -5 5 5
change_box boundary s s s # this will work :pre
IMPORTANT NOTE: Unlike the earlier "displace_box" version of this
command, atom remapping is NOT performed by default. This command
allows remapping to be done in a more general way, exactly when you
specify it (zero or more times) in the sequence of transformations.
Thus if you do not use the {remap} keyword, atom coordinates will not
be changed even if the box size/shape changes. If a uniformly
strained state is desired, the {remap} keyword should be specified.
IMPORTANT NOTE: It is possible to lose atoms with this command.
E.g. by changing the box without remapping the atoms, and having atoms
end up outside of non-periodic boundaries. It is also possible to
alter bonds between atoms straddling a boundary in bad ways. E.g. by
converting a boundary from periodic to non-periodic. It is also
possible when remapping atoms to put them (nearly) on top of each
other. E.g. by converting a boundary from non-periodic to periodic.
All of these will typically lead to bad dynamics and/or generate error
messages.
IMPORTANT NOTE: The simulation box size/shape can be changed by
arbitrarily large amounts by this command. This is not a problem,
except that the mapping of processors to the simulation box is not
changed from its initial 3d configuration; see the
"processors"_processors.html command. Thus, if the box size/shape
changes dramatically, the mapping of processors to the simulation box
may not end up as optimal as the initial mapping attempted to be.
IMPORTANT NOTE: Because the keywords used in this command are applied
one at a time to the simulation box and the atoms in it, care must be
taken with triclinic cells to avoid exceeding the limits on skew after
each transformation in the sequence. If skew is exceeded before the
final transformation this can be avoided by changing the order of the
sequence, or breaking the transformation into two or more smaller
transformations. For more information on the allowed limits for box
skew see the discussion on triclinic boxes on "this
page"_Section_howto.html#howto_12.
:line
For the {x}, {y}, and {z} parameters, this is the meaning of their
styles and values.
For style {final}, the final lo and hi box boundaries of a dimension
are specified. The values can be in lattice or box distance units.
See the discussion of the units keyword below.
For style {delta}, plus or minus changes in the lo/hi box boundaries
of a dimension are specified. The values can be in lattice or box
distance units. See the discussion of the units keyword below.
For style {scale}, a multiplicative factor to apply to the box length
of a dimension is specified. For example, if the initial box length
is 10, and the factor is 1.1, then the final box length will be 11. A
factor less than 1.0 means compression.
The {volume} style changes the specified dimension in such a way that
the overall box volume remains constant with respect to the operation
performed by the preceding keyword. The {volume} style can only be
used following a keyword that changed the volume, which is any of the
{x}, {y}, {z} keywords. If the preceding keyword "key" had a {volume}
style, then both it and the current keyword apply to the keyword
preceding "key". I.e. this sequence of keywords is allowed:
change_box all x scale 1.1 y volume z volume :pre
The {volume} style changes the associated dimension so that the
overall box volume is unchanged relative to its value before the
preceding keyword was invoked.
If the following command is used, then the z box length will shrink by
the same 1.1 factor the x box length was increased by:
change_box all x scale 1.1 z volume :pre
If the following command is used, then the y,z box lengths will each
shrink by sqrt(1.1) to keep the volume constant. In this case, the
y,z box lengths shrink so as to keep their relative aspect ratio
constant:
change_box all"x scale 1.1 y volume z volume :pre
If the following command is used, then the final box will be a factor
of 10% larger in x and y, and a factor of 21% smaller in z, so as to
keep the volume constant:
change_box all x scale 1.1 z volume y scale 1.1 z volume :pre
IMPORTANT NOTE: For solids or liquids, when one dimension of the box
is expanded, it may be physically undesirable to hold the other 2 box
lengths constant since that implies a density change. For solids,
adjusting the other dimensions via the {volume} style may make
physical sense (just as for a liquid), but may not be correct for
materials and potentials whose Poisson ratio is not 0.5.
For the {scale} and {volume} styles, the box length is expanded or
compressed around its mid point.
:line
For the {xy}, {xz}, and {yz} parameters, this is the meaning of their
styles and values. Note that changing the tilt factors of a triclinic
box does not change its volume.
For style {final}, the final tilt factor is specified. The value
can be in lattice or box distance units. See the discussion of the
units keyword below.
For style {delta}, a plus or minus change in the tilt factor is
specified. The value can be in lattice or box distance units. See
the discussion of the units keyword below.
All of these styles change the xy, xz, yz tilt factors. In LAMMPS,
tilt factors (xy,xz,yz) for triclinic boxes are required to be no more
than half the distance of the parallel box length. For example, if
xlo = 2 and xhi = 12, then the x box length is 10 and the xy tilt
factor must be between -5 and 5. Similarly, both xz and yz must be
between -(xhi-xlo)/2 and +(yhi-ylo)/2. Note that this is not a
limitation, since if the maximum tilt factor is 5 (as in this
example), then configurations with tilt = ..., -15, -5, 5, 15, 25,
... are all equivalent. Any tilt factor specified by this command
must be within these limits.
:line
The {boundary} keyword takes arguments that have exactly the same
meaning as they do for the "boundary"_boundary.html command. In each
dimension, a single letter assigns the same style to both the lower
and upper face of the box. Two letters assigns the first style to the
lower face and the second style to the upper face.
The style {p} means the box is periodic; the other styles mean
non-periodic. For style {f}, the position of the face is fixed. For
style {s}, the position of the face is set so as to encompass the
atoms in that dimension (shrink-wrapping), no matter how far they
move. For style {m}, shrink-wrapping occurs, but is bounded by the
current box edge in that dimension, so that the box will become no
smaller. See the "boundary"_boundary.html command for more
explanation of these style options.
Note that the "boundary" command itself can only be used before the
simulation box is defined via a "read_data"_read_data.html or
"create_box"_create_box.html or "read_restart"_read_restart.html
command. This command allows the boundary conditions to be changed
later in your input script. Also note that the
"read_restart"_read_restart.html will change boundary conditions to
match what is stored in the restart file. So if you wish to change
them, you should use the change_box command after the read_restart
command.
:line
The {ortho} and {triclinic} keywords convert the simulation box to be
orthogonal or triclinic (non-orthongonal). See "this
section"_Section_howto#howto_13 for a discussion of how non-orthongal
boxes are represented in LAMMPS.
The simulation box is defined as either orthogonal or triclinic when
it is created via the "create_box"_create_box.html,
"read_data"_read_data.html, or "read_restart"_read_restart.html
commands.
These keywords allow you to toggle the existing simulation box from
orthogonal to triclinic and vice versa. For example, an initial
equilibration simulation can be run in an orthogonal box, the box can
be toggled to triclinic, and then a "non-equilibrium MD (NEMD)
simulation"_Section_howto.html#howto_13 can be run with deformation
via the "fix deform"_fix_deform.html command.
If the simulation box is currently triclinic and has non-zero tilt in
xy, yz, or xz, then it cannot be converted to an orthogonal box.
:line
The {set} keyword saves the current box size/shape. This can be
useful if you wish to use the {remap} keyword more than once or if you
wish it to be applied to an intermediate box size/shape in a sequence
of keyword operations. Note that the box size/shape is saved before
any of the keywords are processed, i.e. the box size/shape at the time
the create_box command is encountered in the input script.
The {remap} keyword remaps atom coordinates from the last saved box
size/shape to the current box state. For example, if you stretch the
box in the x dimension or tilt it in the xy plane via the {x} and {xy}
keywords, then the {remap} commmand will dilate or tilt the atoms to
conform to the new box size/shape, as if the atoms moved with the box
as it deformed.
Note that this operation is performed without regard to periodic
boundaries. Also, any shrink-wrapping of non-periodic boundaries (see
the "boundary"_boundary.html command) occurs after all keywords,
including this one, have been processed.
Only atoms in the specified group are remapped.
:line
The {units} keyword determines the meaning of the distance units used
to define various arguments. A {box} value selects standard distance
units as defined by the "units"_units.html command, e.g. Angstroms for
units = real or metal. A {lattice} value means the distance units are
in lattice spacings. The "lattice"_lattice.html command must have
been previously used to define the lattice spacing.
:line
[Restrictions:]
If you use the {ortho} or {triclinic} keywords, then at the point in
the input script when this command is issued, no "dumps"_dump.html can
be active, nor can a "fix ave/spatial"_fix_ave_spatial.html or "fix
deform"_fix_deform.html be active. This is because these commands
test whether the simulation box is orthogonal when they are first
issued. Note that these commands can be used in your script before a
change_box command is issued, so long as an "undump"_undump.html or
"unfix"_unfix.html command is also used to turn them off.
[Related commands:]
"fix deform"_fix_deform.html, "boundary"_boundary.html
[Default:]
The option default is units = lattice.