forked from lijiext/lammps
56 lines
1.3 KiB
HTML
56 lines
1.3 KiB
HTML
<HTML>
|
|
<CENTER><A HREF = "http://lammps.sandia.gov">LAMMPS WWW Site</A> - <A HREF = "Manual.html">LAMMPS Documentation</A> - <A HREF = "Section_commands.html#comm">LAMMPS Commands</A>
|
|
</CENTER>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<HR>
|
|
|
|
<H3>pair_style yukawa command
|
|
</H3>
|
|
<P><B>Syntax:</B>
|
|
</P>
|
|
<PRE>pair_style yukawa kappa cutoff
|
|
</PRE>
|
|
<UL><LI>kappa = screening length (inverse distance units)
|
|
<LI>cutoff = global cutoff for Yukawa interactions (distance units)
|
|
</UL>
|
|
<P><B>Examples:</B>
|
|
</P>
|
|
<PRE>pair_style yukawa 2.0 2.5
|
|
pair_coeff 1 1 100.0 2.3
|
|
pair_coeff * * 100.0
|
|
</PRE>
|
|
<P><B>Description:</B>
|
|
</P>
|
|
<P>Style <I>yukawa</I> computes pairwise interactions with the formula
|
|
</P>
|
|
<CENTER><IMG SRC = "Eqs/pair_yukawa.jpg">
|
|
</CENTER>
|
|
<P>Rc is the cutoff.
|
|
</P>
|
|
<P>The following coefficients must be defined for each pair of atoms
|
|
types via the <A HREF = "pair_coeff.html">pair_coeff</A> command as in the examples
|
|
above, or in the data file or restart files read by the
|
|
<A HREF = "read_data.html">read_data</A> or <A HREF = "read_restart.html">read_restart</A>
|
|
commands:
|
|
</P>
|
|
<UL><LI>A (energy units)
|
|
<LI>cutoff (distance units)
|
|
</UL>
|
|
<P>The last coefficient is optional. If not specified, the global yukawa
|
|
cutoff is used.
|
|
</P>
|
|
<P><B>Restrictions:</B> none
|
|
</P>
|
|
<P><B>Related commands:</B>
|
|
</P>
|
|
<P><A HREF = "pair_coeff.html">pair_coeff</A>
|
|
</P>
|
|
<P><B>Default:</B> none
|
|
</P>
|
|
</HTML>
|