<HTML>
|
|
<CENTER><A HREF = "http://lammps.sandia.gov">LAMMPS WWW Site</A> - <A HREF = "Manual.html">LAMMPS Documentation</A> - <A HREF = "Section_commands.html#comm">LAMMPS Commands</A>
|
|
</CENTER>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<HR>
|
|
|
|
<H3>fix addtorque command
|
|
</H3>
|
|
<P><B>Syntax:</B>
|
|
</P>
|
|
<PRE>fix ID group-ID addtorque Tx Ty Tz
|
|
</PRE>
|
|
<UL><LI>ID, group-ID are documented in <A HREF = "fix.html">fix</A> command
|
|
|
|
<LI>addtorque = style name of this fix command
|
|
|
|
<LI>Tx,Ty,Tz = torque component values (torque units)
|
|
|
|
<LI>any of Tx,Ty,Tz can be a variable (see below)
|
|
|
|
|
|
</UL>
|
|
<P><B>Examples:</B>
|
|
</P>
|
|
<PRE>fix kick bead addtorque 2.0 3.0 5.0
|
|
fix kick bead addtorque 0.0 0.0 v_oscillate
|
|
</PRE>
|
|
<P><B>Description:</B>
|
|
</P>
|
|
<P>Add a set of forces to each atom in
|
|
the group such that:
|
|
</P>
|
|
<UL><LI>the components of the total torque applied on the group (around its
|
|
center of mass) are Tx,Ty,Tz
|
|
|
|
<LI>the group would move as a rigid body in the absence of other
|
|
forces.
|
|
</UL>
|
|
<P>This command can be used to drive a group of atoms into rotation.
|
|
</P>
|
|
<P>Any of the 3 quantities defining the torque components can be specified
|
|
as an equal-style <A HREF = "variable.html">variable</A>, namely <I>Tx</I>,
|
|
<I>Ty</I>, <I>Tz</I>. If the value is a variable, it should be specified as
|
|
v_name, where name is the variable name. In this case, the variable
|
|
will be evaluated each timestep, and its value used to determine the
|
|
torque component.
|
|
</P>
|
|
<P>Equal-style variables can specify formulas with various mathematical
|
|
functions, and include <A HREF = "thermo_style.html">thermo_style</A> command
|
|
keywords for the simulation box parameters and timestep and elapsed
|
|
time. Thus it is easy to specify a time-dependent torque.
|
|
</P>
|
|
<HR>
|
|
|
|
<P><B>Restart, fix_modify, output, run start/stop, minimize info:</B>
|
|
</P>
|
|
<P>No information about this fix is written to <A HREF = "restart.html">binary restart
|
|
files</A>.
|
|
</P>
|
|
<P>The <A HREF = "fix_modify.html">fix_modify</A> <I>energy</I> option is supported by this
|
|
fix to add the potential "energy" inferred by the added forces to the
|
|
system's potential energy as part of <A HREF = "thermo_style.html">thermodynamic
|
|
output</A>. This is a fictitious quantity but is
|
|
needed so that the <A HREF = "minimize.html">minimize</A> command can include the
|
|
forces added by this fix in a consistent manner. I.e. there is a
|
|
decrease in potential energy when atoms move in the direction of the
|
|
added forces.
|
|
</P>
|
|
<P>This fix computes a global scalar and a global 3-vector,
|
|
which can be accessed by various <A HREF = "Section_howto.html#4_15">output
|
|
commands</A>. The scalar is the potential energy
|
|
discussed above. The vector is the total torque on the group of atoms
|
|
before the forces on individual atoms are changed by the fix. The
|
|
scalar and vector values calculated by this fix are "extensive".
|
|
</P>
|
|
<P>No parameter of this fix can be used with the <I>start/stop</I> keywords of
|
|
the <A HREF = "run.html">run</A> command.
|
|
</P>
|
|
<P>The forces due to this fix are imposed during an energy minimization,
|
|
invoked by the <A HREF = "minimize.html">minimize</A> command. You should not
|
|
specify force components with a variable that has time-dependence for
|
|
use with a minimizer, since the minimizer increments the timestep as
|
|
the iteration count during the minimization.
|
|
</P>
|
|
<P><B>Restrictions:</B>
|
|
</P>
|
|
<P>This fix is part of the "user-misc" package. It is only enabled if
|
|
LAMMPS was built with that package. See the <A HREF = "Section_start.html#2_3">Making
|
|
LAMMPS</A> section for more info.
|
|
</P>
|
|
<P><B>Related commands:</B>
|
|
</P>
|
|
<P><A HREF = "fix_addforce.html">fix addforce</A>
|
|
</P>
|
|
<P><B>Default:</B> none
|
|
</P>
|
|
</HTML>
|