"LAMMPS WWW Site"_lws - "LAMMPS Documentation"_ld - "LAMMPS Commands"_lc :c
|
|
|
|
:link(lws,http://lammps.sandia.gov)
|
|
:link(ld,Manual.html)
|
|
:link(lc,Section_commands.html#comm)
|
|
|
|
:line
|
|
|
|
fix nvt command :h3
|
|
fix nvt/cuda command :h3
|
|
fix npt command :h3
|
|
fix npt/cuda command :h3
|
|
fix nph command :h3
|
|
|
|
[Syntax:]
|
|
|
|
fix ID group-ID style_name keyword value ... :pre
|
|
|
|
ID, group-ID are documented in "fix"_fix.html command :ulb,l
|
|
style_name = {nvt} or {npt} or {nph} :l
|
|
one or more keyword value pairs may be appended
|
|
keyword = {temp} or {iso} or {aniso} or {tri} or {x} or {y} or {z} or {xy} or {yz} or {xz} or {couple} or {tchain} or {pchain} or {mtk} or {tloop} or {ploop} or {nreset} or {drag} or {dilate} or {scaleyz} or {scalexz} or {scalexy}
|
|
{temp} values = Tstart Tstop Tdamp
|
|
Tstart,Tstop = external temperature at start/end of run
|
|
Tdamp = temperature damping parameter (time units)
|
|
{iso} or {aniso} or {tri} values = Pstart Pstop Pdamp
|
|
Pstart,Pstop = scalar external pressure at start/end of run (pressure units)
|
|
Pdamp = pressure damping parameter (time units)
|
|
{x} or {y} or {z} or {xy} or {yz} or {xz} values = Pstart Pstop Pdamp
|
|
Pstart,Pstop = external stress tensor component at start/end of run (pressure units)
|
|
Pdamp = stress damping parameter (time units)
|
|
{couple} = {none} or {xyz} or {xy} or {yz} or {xz}
|
|
{tchain} value = N
|
|
N = length of thermostat chain (1 = single thermostat)
|
|
{pchain} values = N
|
|
N length of thermostat chain on barostat (0 = no thermostat)
|
|
{mtk} value = {yes} or {no} = add in MTK adjustment term or not
|
|
{tloop} value = M
|
|
M = number of sub-cycles to perform on thermostat
|
|
{ploop} value = M
|
|
M = number of sub-cycles to perform on barostat thermostat
|
|
{nreset} value = reset reference cell every this many timesteps
|
|
{drag} value = Df
|
|
Df = drag factor added to barostat/thermostat (0.0 = no drag)
|
|
{dilate} value = dilate-group-ID
|
|
dilate-group-ID = only dilate atoms in this group due to barostat volume changes
|
|
{scaleyz} value = {yes} or {no} = scale yz with lz
|
|
{scalexz} value = {yes} or {no} = scale xz with lz
|
|
{scalexy} value = {yes} or {no} = scale xy with ly
|
|
{fixedpoint} values = x y z
|
|
x,y,z = perform barostat dilation/contraction around this point (distance units) :pre
|
|
|
|
:ule
|
|
|
|
[Examples:]
|
|
|
|
fix 1 all nvt temp 300.0 300.0 100.0
|
|
fix 1 water npt temp 300.0 300.0 100.0 iso 0.0 0.0 1000.0
|
|
fix 2 jello npt temp 300.0 300.0 100.0 tri 5.0 5.0 1000.0
|
|
fix 2 ice nph x 1.0 1.0 0.5 y 2.0 2.0 0.5 z 3.0 3.0 0.5 yz 0.1 0.1 0.5 xz 0.2 0.2 0.5 xy 0.3 0.3 0.5 nreset 1000 :pre
|
|
|
|
[Description:]
|
|
|
|
These commands perform time integration on Nose-Hoover style
|
|
non-Hamiltonian equations of motion which are designed to generate
|
|
positions and velocities sampled from the canonical (nvt),
|
|
isothermal-isobaric (npt), and isenthalpic (nph) ensembles. This
|
|
updates the position and velocity for atoms in the group each
|
|
timestep.
|
|
|
|
The thermostatting and barostatting is achieved by adding some dynamic
|
|
variables which are coupled to the particle velocities
|
|
(thermostatting) and simulation domain dimensions (barostatting). In
|
|
addition to basic thermostatting and barostatting, these fixes can
|
|
also create a chain of thermostats coupled to the particle thermostat,
|
|
and another chain of thermostats coupled to the barostat
|
|
variables. The barostat can be coupled to the overall box volume, or
|
|
to individual dimensions, including the {xy}, {xz} and {yz} tilt
|
|
dimensions. The external pressure of the barostat can be specified as
|
|
either a scalar pressure (isobaric ensemble) or as components of a
|
|
symmetric stress tensor (constant stress ensemble). When used
|
|
correctly, the time-averaged temperature and stress tensor of the
|
|
particles will match the target values specified by Tstart/Tstop and
|
|
Pstart/Pstop.
|
|
|
|
The equations of motion used are those of Shinoda et al in
|
|
"(Shinoda)"_#Shinoda, which combine the hydrostatic equations of
|
|
Martyna, Tobias and Klein in "(Martyna)"_#Martyna with the strain
|
|
energy proposed by Parrinello and Rahman in
|
|
"(Parrinello)"_#Parrinello. The time integration schemes closely
|
|
follow the time-reversible measure-preserving Verlet and rRESPA
|
|
integrators derived by Tuckerman et al. in "(Tuckerman)"_#Tuckerman.
|
|
|
|
:line
|
|
|
|
The thermostat parameters for fix styles {nvt} and {npt} is specified
|
|
using the {temp} keyword. Other thermostat-related keywords are
|
|
{tchain}, {tloop} and {drag}, which are discussed below.
|
|
|
|
The thermostat is applied to only the translational degrees of freedom
|
|
for the particles. The translational degrees of freedom can also have
|
|
a bias velocity removed before thermostatting takes place; see the
|
|
description below. The desired temperature at each timestep is a
|
|
ramped value during the run from {Tstart} to {Tstop}. The {Tdamp}
|
|
parameter is specified in time units and determines how rapidly the
|
|
temperature is relaxed. For example, a value of 10.0 means to relax
|
|
the temperature in a timespan of (roughly) 10 time units (e.g. tau or
|
|
fmsec or psec - see the "units"_units.html command). The atoms in the
|
|
fix group are the only ones whose velocities and positions are updated
|
|
by the velocity/position update portion of the integration.
|
|
|
|
IMPORTANT NOTE: A Nose-Hoover thermostat will not work well for
|
|
arbitrary values of {Tdamp}. If {Tdamp} is too small, the temperature
|
|
can fluctuate wildly; if it is too large, the temperature will take a
|
|
very long time to equilibrate. A good choice for many models is a
|
|
{Tdamp} of around 100 timesteps. Note that this is NOT the same as
|
|
100 time units for most "units"_units.html settings.
|
|
|
|
:line
|
|
|
|
The barostat parameters for fix styles {npt} and {nph} is specified
|
|
using one or more of the {iso}, {aniso}, {tri}, {x}, {y}, {z}, {xy},
|
|
{xz}, {yz}, and {couple} keywords. These keywords give you the
|
|
ability to specify all 6 components of an external stress tensor, and
|
|
to couple various of these components together so that the dimensions
|
|
they represent are varied together during a constant-pressure
|
|
simulation.
|
|
|
|
Other barostat-related keywords are {pchain}, {mtk}, {ploop},
|
|
{nreset}, {drag}, and {dilate}, which are discussed below.
|
|
|
|
Orthogonal simulation boxes have 3 adjustable dimensions (x,y,z).
|
|
Triclinic (non-orthogonal) simulation boxes have 6 adjustable
|
|
dimensions (x,y,z,xy,xz,yz). The "create_box"_create_box.html, "read
|
|
data"_read_data.html, and "read_restart"_read_restart.html commands
|
|
specify whether the simulation box is orthogonal or non-orthogonal
|
|
(triclinic) and explain the meaning of the xy,xz,yz tilt factors.
|
|
|
|
The target pressures for each of the 6 components of the stress tensor
|
|
can be specified independently via the {x}, {y}, {z}, {xy}, {xz}, {yz}
|
|
keywords, which correspond to the 6 simulation box dimensions. For
|
|
each component, the external pressure or tensor component at each
|
|
timestep is a ramped value during the run from {Pstart} to {Pstop}.
|
|
If a target pressure is specified for a component, then the
|
|
corresponding box dimension will change during a simulation. For
|
|
example, if the {y} keyword is used, the y-box length will change. If
|
|
the {xy} keyword is used, the xy tilt factor will change. A box
|
|
dimension will not change if that component is not specified, although
|
|
you have the option to change that dimension via the "fix
|
|
deform"_fix_deform.html command.
|
|
|
|
Note that in order to use the {xy}, {xz}, or {yz} keywords, the
|
|
simulation box must be triclinic, even if its initial tilt factors are
|
|
0.0.
|
|
|
|
For all barostat keywords, the {Pdamp} parameter operates like the
|
|
{Tdamp} parameter, determining the time scale on which pressure is
|
|
relaxed. For example, a value of 10.0 means to relax the pressure in
|
|
a timespan of (roughly) 10 time units (e.g. tau or fmsec or psec - see
|
|
the "units"_units.html command).
|
|
|
|
IMPORTANT NOTE: A Nose-Hoover barostat will not work well for
|
|
arbitrary values of {Pdamp}. If {Pdamp} is too small, the pressure
|
|
and volume can fluctuate wildly; if it is too large, the pressure will
|
|
take a very long time to equilibrate. A good choice for many models
|
|
is a {Pdamp} of around 1000 timesteps. Note that this is NOT the same
|
|
as 1000 time units for most "units"_units.html settings.
|
|
|
|
Regardless of what atoms are in the fix group (the only atoms which
|
|
are time integrated), a global pressure or stress tensor is computed
|
|
for all atoms. Similarly, when the size of the simulation box is
|
|
changed, all atoms are re-scaled to new positions, unless the keyword
|
|
{dilate} is specified with a {dilate-group-ID} for a group that
|
|
represents a subset of the atoms. This can be useful, for example, to
|
|
leave the coordinates of atoms in a solid substrate unchanged and
|
|
controlling the pressure of a surrounding fluid. This option should
|
|
be used with care, since it can be unphysical to dilate some atoms and
|
|
not others, because it can introduce large, instantaneous
|
|
displacements between a pair of atoms (one dilated, one not) that are
|
|
far from the dilation origin. Also note that for atoms not in the fix
|
|
group, a separate time integration fix like "fix nve"_fix_nve.html or
|
|
"fix nvt"_fix_nh.html can be used on them, independent of whether they
|
|
are dilated or not.
|
|
|
|
:line
|
|
|
|
The {couple} keyword allows two or three of the diagonal components of
|
|
the pressure tensor to be "coupled" together. The value specified
|
|
with the keyword determines which are coupled. For example, {xz}
|
|
means the {Pxx} and {Pzz} components of the stress tensor are coupled.
|
|
{Xyz} means all 3 diagonal components are coupled. Coupling means two
|
|
things: the instantaneous stress will be computed as an average of the
|
|
corresponding diagonal components, and the coupled box dimensions will
|
|
be changed together in lockstep, meaning coupled dimensions will be
|
|
dilated or contracted by the same percentage every timestep. The
|
|
{Pstart}, {Pstop}, {Pdamp} parameters for any coupled dimensions must
|
|
be identical. {Couple xyz} can be used for a 2d simulation; the {z}
|
|
dimension is simply ignored.
|
|
|
|
:line
|
|
|
|
The {iso}, {aniso}, and {tri} keywords are simply shortcuts that are
|
|
equivalent to specifying several other keywords together.
|
|
|
|
The keyword {iso} means couple all 3 diagonal components together when
|
|
pressure is computed (hydrostatic pressure), and dilate/contract the
|
|
dimensions together. Using "iso Pstart Pstop Pdamp" is the same as
|
|
specifying these 4 keywords:
|
|
|
|
x Pstart Pstop Pdamp
|
|
y Pstart Pstop Pdamp
|
|
z Pstart Pstop Pdamp
|
|
couple xyz :pre
|
|
|
|
The keyword {aniso} means {x}, {y}, and {z} dimensions are controlled
|
|
independently using the {Pxx}, {Pyy}, and {Pzz} components of the
|
|
stress tensor as the driving forces, and the specified scalar external
|
|
pressure. Using "aniso Pstart Pstop Pdamp" is the same as specifying
|
|
these 4 keywords:
|
|
|
|
x Pstart Pstop Pdamp
|
|
y Pstart Pstop Pdamp
|
|
z Pstart Pstop Pdamp
|
|
couple none :pre
|
|
|
|
The keyword {tri} means {x}, {y}, {z}, {xy}, {xz}, and {yz} dimensions
|
|
are controlled independently using their individual stress components
|
|
as the driving forces, and the specified scalar pressure as the
|
|
external normal stress. Using "tri Pstart Pstop Pdamp" is the same as
|
|
specifying these 7 keywords:
|
|
|
|
x Pstart Pstop Pdamp
|
|
y Pstart Pstop Pdamp
|
|
z Pstart Pstop Pdamp
|
|
xy 0.0 0.0 Pdamp
|
|
yz 0.0 0.0 Pdamp
|
|
xz 0.0 0.0 Pdamp
|
|
couple none :pre
|
|
|
|
:line
|
|
|
|
In some cases (e.g. for solids) the pressure (volume) and/or
|
|
temperature of the system can oscillate undesirably when a Nose/Hoover
|
|
barostat and thermostat is applied. The optional {drag} keyword will
|
|
damp these oscillations, although it alters the Nose/Hoover equations.
|
|
A value of 0.0 (no drag) leaves the Nose/Hoover formalism unchanged.
|
|
A non-zero value adds a drag term; the larger the value specified, the
|
|
greater the damping effect. Performing a short run and monitoring the
|
|
pressure and temperature is the best way to determine if the drag term
|
|
is working. Typically a value between 0.2 to 2.0 is sufficient to
|
|
damp oscillations after a few periods. Note that use of the drag
|
|
keyword will interfere with energy conservation and will also change
|
|
the distribution of positions and velocities so that they do not
|
|
correspond to the nominal NVT, NPT, or NPH ensembles.
|
|
|
|
An alternative way to control initial oscillations is to use chain
|
|
thermostats. The keyword {tchain} determines the number of thermostats
|
|
in the particle thermostat. A value of 1 corresponds to the original
|
|
Nose-Hoover thermostat. The keyword {pchain} specifies the number of
|
|
thermostats in the chain thermostatting the barostat degrees of
|
|
freedom. A value of 0 corresponds to no thermostatting of the
|
|
barostat variables.
|
|
|
|
The {mtk} keyword controls whether or not the correction terms due to
|
|
Martyna, Tuckerman, and Klein are included in the equations of motion
|
|
"(Martyna)"_#Martyna. Specifying {no} reproduces the original
|
|
Hoover barostat, whose volume probability distribution function
|
|
differs from the true NPT and NPH ensembles by a factor of 1/V. Hence
|
|
using {yes} is more correct, but in many cases the difference is
|
|
negligible.
|
|
|
|
The keyword {tloop} can be used to improve the accuracy of integration
|
|
scheme at little extra cost. The initial and final updates of the
|
|
thermostat variables are broken up into {tloop} substeps, each of
|
|
length {dt}/{tloop}. This corresponds to using a first-order
|
|
Suzuki-Yoshida scheme "(Tuckerman2006)"_#Tuckerman2006. The keyword
|
|
{ploop} does the same thing for the barostat thermostat.
|
|
|
|
The keyword {nreset} controls how often the reference dimensions used
|
|
to define the strain energy are reset. If this keyword is not used,
|
|
or is given a value of zero, then the reference dimensions are set to
|
|
those of the initial simulation domain and are never changed. If the
|
|
simulation domain changes significantly during the simulation, then
|
|
the final average pressure tensor will differ significantly from the
|
|
specified values of the external stress tensor. A value of {nstep}
|
|
means that every {nstep} timesteps, the reference dimensions are set
|
|
to those of the current simulation domain.
|
|
|
|
The {scaleyz}, {scalexz}, and {scalexy} keywords control whether or
|
|
not the corresponding tilt factors are scaled with the associated box
|
|
dimensions when barostatting triclinic periodic cells. The default
|
|
values {yes} will turn on scaling, which corresponds to adjusting the
|
|
linear dimensions of the cell while preserving its shape. Choosing
|
|
{no} ensures that the tilt factors are not scaled with the box
|
|
dimensions. See below for restrictions and default values in different
|
|
situations. In older versions of LAMMPS, scaling of tilt factors was
|
|
not performed. The old behavior can be recovered by setting all three
|
|
scale keywords to {no}.
|
|
|
|
The {fixedpoint} keyword specifies the fixed point for barostat volume
|
|
changes. By default, it is the center of the box. Whatever point is
|
|
chosen will not move during the simulation. For example, if the lower
|
|
periodic boundaries pass through (0,0,0), and this point is provided
|
|
to {fixedpoint}, then the lower periodic boundaries will remain at
|
|
(0,0,0), while the upper periodic boundaries will move twice as
|
|
far. In all cases, the particle trajectories are unaffected by the
|
|
chosen value, except for a time-dependent constant translation of
|
|
positions.
|
|
|
|
:line
|
|
|
|
IMPORTANT NOTE: Using a barostat coupled to tilt dimensions {xy},
|
|
{xz}, {yz} can sometimes result in arbitrarily large values of the
|
|
tilt dimensions, i.e. a dramatically deformed simulation box. LAMMPS
|
|
allows the tilt factors to grow a little beyond the normal limit of
|
|
half the box length (0.6 times the box length), and then performs a
|
|
box "flip" to an equivalent periodic cell. The flip operation is
|
|
described in more detail in the doc page for "fix
|
|
deform"_fix_deform.html. Both the barostat dynamics and the atom
|
|
trajectories are unaffected by this operation. However, if a tilt
|
|
factor is incremented by a large amount (1.5 times the box length) on
|
|
a single timestep, LAMMPS can not accomodate this event and will
|
|
terminate the simulation with an error. This error typically indicates
|
|
that there is something badly wrong with how the simulation was
|
|
constructed, such as specifying values of {Pstart} that are too far
|
|
from the current stress value, or specifying a timestep that is too
|
|
large. Triclinic barostatting should be used with care. This also is
|
|
true for other barostat styles, although they tend to be more
|
|
forgiving of insults. In particular, it is important to recognize that
|
|
equilibrium liquids can not support a shear stress and that
|
|
equilibrium solids can not support shear stresses that exceed the
|
|
yield stress.
|
|
|
|
The one exception to this rule is if the 1st dimension in the tilt
|
|
factor (x for xy) is non-periodic. In that case, the limits on the
|
|
tilt factor are not enforced, since flipping the box in that dimension
|
|
does not change the atom positions due to non-periodicity. In this
|
|
mode, if you tilt the system to extreme angles, the simulation will
|
|
simply become inefficient due to the highly skewed simulation box.
|
|
|
|
IMPORTANT NOTE: Unlike the "fix
|
|
temp/berendsen"_fix_temp_berendsen.html command which performs
|
|
thermostatting but NO time integration, these fixes perform
|
|
thermostatting/barostatting AND time integration. Thus you should not
|
|
use any other time integration fix, such as "fix nve"_fix_nve.html on
|
|
atoms to which this fix is applied. Likewise, the {temp} options for
|
|
fix nvt and fix npt should not normally be used on atoms that also
|
|
have their temperature controlled by another fix - e.g. by "fix
|
|
langevin"_fix_nh.html or "fix temp/rescale"_fix_temp_rescale.html
|
|
commands.
|
|
|
|
See "this howto section"_Section_howto.html#howto_16 of the manual for
|
|
a discussion of different ways to compute temperature and perform
|
|
thermostatting and barostatting.
|
|
|
|
:line
|
|
|
|
These fixes compute a temperature and pressure each timestep. To do
|
|
this, the fix creates its own computes of style "temp" and "pressure",
|
|
as if one of these two sets of commands had been issued:
|
|
|
|
compute fix-ID_temp group-ID temp
|
|
compute fix-ID_press group-ID pressure fix-ID_temp :pre
|
|
|
|
compute fix-ID_temp all temp
|
|
compute fix-ID_press all pressure fix-ID_temp :pre
|
|
|
|
See the "compute temp"_compute_temp.html and "compute
|
|
pressure"_compute_pressure.html commands for details. Note that the
|
|
IDs of the new computes are the fix-ID + underscore + "temp" or fix_ID
|
|
+ underscore + "press". For fix nvt, the group for the new computes
|
|
is the same as the fix group. For fix nph and fix npt, the group for
|
|
the new computes is "all" since pressure is computed for the entire
|
|
system.
|
|
|
|
Note that these are NOT the computes used by thermodynamic output (see
|
|
the "thermo_style"_thermo_style.html command) with ID = {thermo_temp}
|
|
and {thermo_press}. This means you can change the attributes of this
|
|
fix's temperature or pressure via the
|
|
"compute_modify"_compute_modify.html command or print this temperature
|
|
or pressure during thermodynamic output via the "thermo_style
|
|
custom"_thermo_style.html command using the appropriate compute-ID.
|
|
It also means that changing attributes of {thermo_temp} or
|
|
{thermo_press} will have no effect on this fix.
|
|
|
|
Like other fixes that perform thermostatting, fix nvt and fix npt can
|
|
be used with "compute commands"_compute.html that calculate a
|
|
temperature after removing a "bias" from the atom velocities.
|
|
E.g. removing the center-of-mass velocity from a group of atoms or
|
|
only calculating temperature on the x-component of velocity or only
|
|
calculating temperature for atoms in a geometric region. This is not
|
|
done by default, but only if the "fix_modify"_fix_modify.html command
|
|
is used to assign a temperature compute to this fix that includes such
|
|
a bias term. See the doc pages for individual "compute
|
|
commands"_compute.html to determine which ones include a bias. In
|
|
this case, the thermostat works in the following manner: the current
|
|
temperature is calculated taking the bias into account, bias is
|
|
removed from each atom, thermostatting is performed on the remaining
|
|
thermal degrees of freedom, and the bias is added back in.
|
|
|
|
:line
|
|
|
|
These fixes can be used with either the {verlet} or {respa}
|
|
"integrators"_run_style.html. When using one of the barostat fixes
|
|
with {respa}, LAMMPS uses an integrator constructed
|
|
according to the following factorization of the Liouville propagator
|
|
(for two rRESPA levels):
|
|
|
|
:c,image(Eqs/fix_nh1.jpg)
|
|
|
|
This factorization differs somewhat from that of Tuckerman et al., in that
|
|
the barostat is only updated at the outermost rRESPA level, whereas
|
|
Tuckerman's factorization requires splitting the pressure into pieces
|
|
corresponding to the forces computed at each rRESPA level. In theory, the
|
|
latter method will exhibit better numerical stability. In practice,
|
|
because Pdamp is normally chosen to be a large multiple of the
|
|
outermost rRESPA timestep, the barostat dynamics are not the
|
|
limiting factor for numerical stability. Both
|
|
factorizations are time-reversible and can be shown to preserve the phase
|
|
space measure of the underlying non-Hamiltonian equations of motion.
|
|
|
|
:line
|
|
|
|
Styles with a {cuda} suffix are functionally the same as the
|
|
corresponding style without the suffix. They have been optimized to
|
|
run faster, depending on your available hardware, as discussed in
|
|
"Section_accelerate"_Section_accelerate.html of the manual. The
|
|
accelerated styles take the same arguments and should produce the same
|
|
results, except for round-off and precision issues.
|
|
|
|
These accelerated styles are part of the USER-CUDA package. They are
|
|
only enabled if LAMMPS was built with that package. See the "Making
|
|
LAMMPS"_Section_start.html#start_3 section for more info.
|
|
|
|
You can specify the accelerated styles explicitly in your input script
|
|
by including their suffix, or you can use the "-suffix command-line
|
|
switch"_Section_start.html#start_7 when you invoke LAMMPS, or you can
|
|
use the "suffix"_suffix.html command in your input script.
|
|
|
|
See "Section_accelerate"_Section_accelerate.html of the manual for
|
|
more instructions on how to use the accelerated styles effectively.
|
|
|
|
:line
|
|
|
|
[Restart, fix_modify, output, run start/stop, minimize info:]
|
|
|
|
These fixes writes the state of all the thermostat and barostat
|
|
variables to "binary restart files"_restart.html. See the
|
|
"read_restart"_read_restart.html command for info on how to re-specify
|
|
a fix in an input script that reads a restart file, so that the
|
|
operation of the fix continues in an uninterrupted fashion.
|
|
|
|
The "fix_modify"_fix_modify.html {temp} and {press} options are
|
|
supported by these fixes. You can use them to assign a
|
|
"compute"_compute.html you have defined to this fix which will be used
|
|
in its thermostatting or barostatting procedure, as described above.
|
|
If you do this, note that the kinetic energy derived from the compute
|
|
temperature should be consistent with the virial term computed using
|
|
all atoms for the pressure. LAMMPS will warn you if you choose to
|
|
compute temperature on a subset of atoms.
|
|
|
|
IMPORTANT NOTE: If both the {temp} and {press} keywords are used in a
|
|
single thermo_modify command (or in two separate commands), then the
|
|
order in which the keywords are specified is important. Note that a
|
|
"pressure compute"_compute_pressure.html defines its own temperature
|
|
compute as an argument when it is specified. The {temp} keyword will
|
|
override this (for the pressure compute being used by fix npt), but
|
|
only if the {temp} keyword comes after the {press} keyword. If the
|
|
{temp} keyword comes before the {press} keyword, then the new pressure
|
|
compute specified by the {press} keyword will be unaffected by the
|
|
{temp} setting.
|
|
|
|
The "fix_modify"_fix_modify.html {energy} option is supported by these
|
|
fixes to add the energy change induced by Nose/Hoover thermostatting
|
|
and barostatting to the system's potential energy as part of
|
|
"thermodynamic output"_thermo_style.html.
|
|
|
|
These fixes compute a global scalar and a global vector of quantities,
|
|
which can be accessed by various "output
|
|
commands"_Section_howto.html#howto_15. The scalar value calculated by
|
|
these fixes is "extensive"; the vector values are "intensive".
|
|
|
|
The scalar is the cumulative energy change due to the fix.
|
|
|
|
The vector stores internal Nose/Hoover thermostat and barostat
|
|
variables. The number and meaning of the vector values depends on
|
|
which fix is used and the settings for keywords {tchain} and {pchain},
|
|
which specify the number of Nose/Hoover chains for the thermostat and
|
|
barostat. If no thermostatting is done, then {tchain} is 0. If no
|
|
barostatting is done, then {pchain} is 0. In the following list,
|
|
"ndof" is 0, 1, 3, or 6, and is the number of degrees of freedom in
|
|
the barostat. Its value is 0 if no barostat is used, else its value
|
|
is 6 if any off-diagonal stress tensor component is barostatted, else
|
|
its value is 1 if {couple xyz} is used or {couple xy} for a 2d
|
|
simulation, otherwise its value is 3.
|
|
|
|
The order of values in the global vector and their meaning is as
|
|
follows. The notation means there are tchain values for eta, followed
|
|
by tchain for eta_dot, followed by ndof for omega, etc:
|
|
|
|
eta\[tchain\] = particle thermostat displacements (unitless)
|
|
eta_dot\[tchain\] = particle thermostat velocities (1/time units)
|
|
omega\[ndof\] = barostat displacements (unitless)
|
|
omega_dot\[ndof\] = barostat velocities (1/time units)
|
|
etap\[pchain\] = barostat thermostat displacements (unitless)
|
|
etap_dot\[pchain\] = barostat thermostat velocities (1/time units)
|
|
PE_eta\[tchain\] = potential energy of each particle thermostat displacement (energy units)
|
|
KE_eta_dot\[tchain\] = kinetic energy of each particle thermostat velocity (energy units)
|
|
PE_omega\[ndof\] = potential energy of each barostat displacement (energy units)
|
|
KE_omega_dot\[ndof\] = kinetic energy of each barostat velocity (energy units)
|
|
PE_etap\[pchain\] = potential energy of each barostat thermostat displacement (energy units)
|
|
KE_etap_dot\[pchain\] = kinetic energy of each barostat thermostat velocity (energy units)
|
|
PE_strain\[1\] = scalar strain energy (energy units) :ul
|
|
|
|
These fixes can ramp their external temperature and pressure over
|
|
multiple runs, using the {start} and {stop} keywords of the
|
|
"run"_run.html command. See the "run"_run.html command for details of
|
|
how to do this.
|
|
|
|
These fixes are not invoked during "energy
|
|
minimization"_minimize.html.
|
|
|
|
:line
|
|
|
|
[Restrictions:]
|
|
|
|
{X}, {y}, {z} cannot be barostatted if the associated dimension is not
|
|
periodic. {Xy}, {xz}, and {yz} can only be barostatted if the
|
|
simulation domain is triclinic and the 2nd dimension in the keyword
|
|
({y} dimension in {xy}) is periodic. {Z}, {xz}, and {yz}, cannot be
|
|
barostatted for 2D simulations. The "create_box"_create_box.html,
|
|
"read data"_read_data.html, and "read_restart"_read_restart.html
|
|
commands specify whether the simulation box is orthogonal or
|
|
non-orthogonal (triclinic) and explain the meaning of the xy,xz,yz
|
|
tilt factors.
|
|
|
|
For the {temp} keyword, the final Tstop cannot be 0.0 since it would
|
|
make the external T = 0.0 at some timestep during the simulation which
|
|
is not allowed in the Nose/Hoover formulation.
|
|
|
|
The {scaleyz yes} and {scalexz yes} keyword/value pairs can not be used
|
|
for 2D simulations. {scaleyz yes}, {scalexz yes}, and {scalexy yes} options
|
|
can only be used if the 2nd dimension in the keyword is periodic,
|
|
and if the tilt factor is not coupled to the barostat via keywords
|
|
{tri}, {yz}, {xz}, and {xy}.
|
|
|
|
[Related commands:]
|
|
|
|
"fix nve"_fix_nve.html, "fix_modify"_fix_modify.html,
|
|
"run_style"_run_style.html
|
|
|
|
[Default:]
|
|
|
|
The keyword defaults are tchain = 3, pchain = 3, mtk = yes, tloop =
|
|
ploop = 1, nreset = 0, drag = 0.0, dilate = all, couple = none,
|
|
scaleyz = scalexz = scalexy = yes if periodic in 2nd dimension and
|
|
not coupled to barostat, otherwise no.
|
|
|
|
:line
|
|
|
|
:link(Martyna)
|
|
[(Martyna)] Martyna, Tobias and Klein, J Chem Phys, 101, 4177 (1994).
|
|
|
|
:link(Parrinello)
|
|
[(Parrinello)] Parrinello and Rahman, J Appl Phys, 52, 7182 (1981).
|
|
|
|
:link(Tuckerman)
|
|
[(Tuckerman)] Tuckerman, Alejandre, Lopez-Rendon, Jochim, and
|
|
Martyna, J Phys A: Math Gen, 39, 5629 (2006).
|
|
|
|
:link(Shinoda)
|
|