forked from lijiext/lammps
274 lines
13 KiB
HTML
274 lines
13 KiB
HTML
<HTML>
|
|
<CENTER><A HREF = "http://lammps.sandia.gov">LAMMPS WWW Site</A> - <A HREF = "Manual.html">LAMMPS Documentation</A> - <A HREF = "Section_commands.html#comm">LAMMPS Commands</A>
|
|
</CENTER>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<HR>
|
|
|
|
<H3>fix langevin command
|
|
</H3>
|
|
<P><B>Syntax:</B>
|
|
</P>
|
|
<PRE>fix ID group-ID langevin Tstart Tstop damp seed keyword values ...
|
|
</PRE>
|
|
<UL><LI>ID, group-ID are documented in <A HREF = "fix.html">fix</A> command
|
|
|
|
<LI>langevin = style name of this fix command
|
|
|
|
<LI>Tstart,Tstop = desired temperature at start/end of run (temperature units)
|
|
|
|
<PRE> Tstart can be a variable (see below)
|
|
</PRE>
|
|
<LI>damp = damping parameter (time units)
|
|
|
|
<LI>seed = random number seed to use for white noise (positive integer)
|
|
|
|
<LI>zero or more keyword/value pairs may be appended
|
|
|
|
<LI>keyword = <I>angmom</I> or <I>omega</I> or <I>scale</I> or <I>tally</I> or <I>zero</I>
|
|
|
|
<PRE> <I>angmom</I> value = <I>no</I> or <I>yes</I>
|
|
<I>no</I> = do not thermostat rotational degrees of freedom via the angular momentum
|
|
<I>yes</I> = do thermostat rotational degrees of freedom via the angular momentum
|
|
<I>omega</I> value = <I>no</I> or <I>yes</I>
|
|
<I>no</I> = do not thermostat rotational degrees of freedom via the angular velocity
|
|
<I>yes</I> = do thermostat rotational degrees of freedom via the angular velocity
|
|
<I>scale</I> values = type ratio
|
|
type = atom type (1-N)
|
|
ratio = factor by which to scale the damping coefficient
|
|
<I>tally</I> value = <I>no</I> or <I>yes</I>
|
|
<I>no</I> = do not tally the energy added/subtracted to atoms
|
|
<I>yes</I> = do tally the energy added/subtracted to atoms
|
|
<I>zero</I> value = <I>no</I> or <I>yes</I>
|
|
<I>no</I> = do not set total random force to zero
|
|
<I>yes</I> = set total random force to zero
|
|
</PRE>
|
|
|
|
</UL>
|
|
<P><B>Examples:</B>
|
|
</P>
|
|
<PRE>fix 3 boundary langevin 1.0 1.0 1000.0 699483
|
|
fix 1 all langevin 1.0 1.1 100.0 48279 scale 3 1.5
|
|
</PRE>
|
|
<P><B>Description:</B>
|
|
</P>
|
|
<P>Apply a Langevin thermostat as described in <A HREF = "#Schneider">(Schneider)</A>
|
|
to a group of atoms which models an interaction with a background
|
|
implicit solvent. Used with <A HREF = "fix_nve.html">fix nve</A>, this command
|
|
performs Brownian dynamics (BD), since the total force on each atom
|
|
will have the form:
|
|
</P>
|
|
<PRE>F = Fc + Ff + Fr
|
|
Ff = - (m / damp) v
|
|
Fr is proportional to sqrt(Kb T m / (dt damp))
|
|
</PRE>
|
|
<P>Fc is the conservative force computed via the usual inter-particle
|
|
interactions (<A HREF = "pair_style.html">pair_style</A>,
|
|
<A HREF = "bond_style.html">bond_style</A>, etc).
|
|
</P>
|
|
<P>The Ff and Fr terms are added by this fix on a per-particle basis.
|
|
See the <A HREF = "pair_dpd.html">pair_style dpd/tstat</A> command for a
|
|
thermostatting option that adds similar terms on a pairwise basis to
|
|
pairs of interacting particles.
|
|
</P>
|
|
<P>Ff is a frictional drag or viscous damping term proportional to the
|
|
particle's velocity. The proportionality constant for each atom is
|
|
computed as m/damp, where m is the mass of the particle and damp is
|
|
the damping factor specified by the user.
|
|
</P>
|
|
<P>Fr is a force due to solvent atoms at a temperature T randomly bumping
|
|
into the particle. As derived from the fluctuation/dissipation
|
|
theorem, its magnitude as shown above is proportional to sqrt(Kb T m /
|
|
dt damp), where Kb is the Boltzmann constant, T is the desired
|
|
temperature, m is the mass of the particle, dt is the timestep size,
|
|
and damp is the damping factor. Random numbers are used to randomize
|
|
the direction and magnitude of this force as described in
|
|
<A HREF = "#Dunweg">(Dunweg)</A>, where a uniform random number is used (instead of
|
|
a Gaussian random number) for speed.
|
|
</P>
|
|
<P>Note that unless you use the <I>omega</I> or <I>angmom</I> keywords, the
|
|
thermostat effect of this fix is applied to only the translational
|
|
degrees of freedom for the particles, which is an important
|
|
consideration if extended spherical or aspherical particles, which
|
|
have rotational degrees of freedom, are being thermostatted. The
|
|
translational degrees of freedom can also have a bias velocity removed
|
|
from them before thermostatting takes place; see the description
|
|
below.
|
|
</P>
|
|
<P>IMPORTANT NOTE: Unlike the <A HREF = "fix_nh.html">fix nvt</A> command which
|
|
performs Nose/Hoover thermostatting AND time integration, this fix
|
|
does NOT perform time integration. It only modifies forces to effect
|
|
thermostatting. Thus you must use a separate time integration fix,
|
|
like <A HREF = "fix_nve.html">fix nve</A> to actually update the velocities and
|
|
positions of atoms using the modified forces. Likewise, this fix
|
|
should not normally be used on atoms that also have their temperature
|
|
controlled by another fix - e.g. by <A HREF = "fix_nh.html">fix nvt</A> or <A HREF = "fix_temp_rescale.html">fix
|
|
temp/rescale</A> commands.
|
|
</P>
|
|
<P>See <A HREF = "Section_howto.html#howto_16">this howto section</A> of the manual for
|
|
a discussion of different ways to compute temperature and perform
|
|
thermostatting.
|
|
</P>
|
|
<P>The desired temperature at each timestep is a ramped value during the
|
|
run from <I>Tstart</I> to <I>Tstop</I>.
|
|
</P>
|
|
<P><I>Tstart</I> can be specified as an equal-style or atom-style
|
|
<A HREF = "variable.html">variable</A>. In this case, the <I>Tstop</I> setting is
|
|
ignored. If the value is a variable, it should be specified as
|
|
v_name, where name is the variable name. In this case, the variable
|
|
will be evaluated each timestep, and its value used to determine the
|
|
target temperature.
|
|
</P>
|
|
<P>Equal-style variables can specify formulas with various mathematical
|
|
functions, and include <A HREF = "thermo_style.html">thermo_style</A> command
|
|
keywords for the simulation box parameters and timestep and elapsed
|
|
time. Thus it is easy to specify a time-dependent temperature.
|
|
</P>
|
|
<P>Atom-style variables can specify the same formulas as equal-style
|
|
variables but can also include per-atom values, such as atom
|
|
coordinates. Thus it is easy to specify a spatially-dependent
|
|
temperature with optional time-dependence as well.
|
|
</P>
|
|
<P>Like other fixes that perform thermostatting, this fix can be used
|
|
with <A HREF = "compute.html">compute commands</A> that remove a "bias" from the
|
|
atom velocities. E.g. removing the center-of-mass velocity from a
|
|
group of atoms or removing the x-component of velocity from the
|
|
calculation. This is not done by default, but only if the
|
|
<A HREF = "fix_modify.html">fix_modify</A> command is used to assign a temperature
|
|
compute to this fix that includes such a bias term. See the doc pages
|
|
for individual <A HREF = "compute.html">compute commands</A> to determine which ones
|
|
include a bias. In this case, the thermostat works in the following
|
|
manner: bias is removed from each atom, thermostatting is performed on
|
|
the remaining thermal degrees of freedom, and the bias is added back
|
|
in.
|
|
</P>
|
|
<P>The <I>damp</I> parameter is specified in time units and determines how
|
|
rapidly the temperature is relaxed. For example, a value of 100.0
|
|
means to relax the temperature in a timespan of (roughly) 100 time
|
|
units (tau or fmsec or psec - see the <A HREF = "units.html">units</A> command).
|
|
The damp factor can be thought of as inversely related to the
|
|
viscosity of the solvent. I.e. a small relaxation time implies a
|
|
hi-viscosity solvent and vice versa. See the discussion about gamma
|
|
and viscosity in the documentation for the <A HREF = "fix_viscous.html">fix
|
|
viscous</A> command for more details.
|
|
</P>
|
|
<P>The random # <I>seed</I> must be a positive integer. A Marsaglia random
|
|
number generator is used. Each processor uses the input seed to
|
|
generate its own unique seed and its own stream of random numbers.
|
|
Thus the dynamics of the system will not be identical on two runs on
|
|
different numbers of processors.
|
|
</P>
|
|
<HR>
|
|
|
|
<P>The keyword/value option pairs are used in the following ways.
|
|
</P>
|
|
<P>The keyword <I>angmom</I> and <I>omega</I> keywords enable thermostatting of
|
|
rotational degrees of freedom in addition to the usual translational
|
|
degrees of freedom. This can only be done for finite-size particles.
|
|
A simulation using atom_style sphere defines an omega for finite-size
|
|
spheres. A simulation using atom_style ellipsoid defines a finite
|
|
size and shape for aspherical particles and an angular momentum. The
|
|
Langevin formulas for thermostatting the rotational degrees of freedom
|
|
are the same as those above, where force is replaced by torque, m is
|
|
replaced by the moment of inertia I, and v is replaced by omega (which
|
|
is derived from the angular momentum in the case of aspherical
|
|
particles). The rotational temperature of the particles can be
|
|
monitored by the <A HREF = "compute_temp_sphere.html">compute temp/sphere</A> and
|
|
<A HREF = "compute_temp_asphere.html">compute temp/asphere</A> commands with their
|
|
rotate options.
|
|
</P>
|
|
<P>The keyword <I>scale</I> allows the damp factor to be scaled up or down by
|
|
the specified factor for atoms of that type. This can be useful when
|
|
different atom types have different sizes or masses. It can be used
|
|
multiple times to adjust damp for several atom types. Note that
|
|
specifying a ratio of 2 increases the relaxation time which is
|
|
equivalent to the solvent's viscosity acting on particles with 1/2 the
|
|
diameter. This is the opposite effect of scale factors used by the
|
|
<A HREF = "fix_viscous.html">fix viscous</A> command, since the damp factor in fix
|
|
<I>langevin</I> is inversely related to the gamma factor in fix <I>viscous</I>.
|
|
Also note that the damping factor in fix <I>langevin</I> includes the
|
|
particle mass in Ff, unlike fix <I>viscous</I>. Thus the mass and size of
|
|
different atom types should be accounted for in the choice of ratio
|
|
values.
|
|
</P>
|
|
<P>The keyword <I>tally</I> enables the calculation of the cumulative energy
|
|
added/subtracted to the atoms as they are thermostatted. Effectively
|
|
it is the energy exchanged between the infinite thermal reservoir and
|
|
the particles. As described below, this energy can then be printed
|
|
out or added to the potential energy of the system to monitor energy
|
|
conservation.
|
|
</P>
|
|
<P>The keyword <I>zero</I> can be used to eliminate drift due to the
|
|
thermostat. Because the random forces on different atoms are
|
|
independent, they do not sum exactly to zero. As a result, this fix
|
|
applies a small random force to the entire system, and the
|
|
center-of-mass of the system undergoes a slow random walk. If the
|
|
keyword <I>zero</I> is set to <I>yes</I>, the total random force is set exactly
|
|
to zero by subtracting off an equal part of it from each atom in the
|
|
group. As a result, the center-of-mass of a system with zero initial
|
|
momentum will not drift over time.
|
|
</P>
|
|
<HR>
|
|
|
|
<P><B>Restart, fix_modify, output, run start/stop, minimize info:</B>
|
|
</P>
|
|
<P>No information about this fix is written to <A HREF = "restart.html">binary restart
|
|
files</A>. Because the state of the random number generator
|
|
is not saved in restart files, this means you cannot do "exact"
|
|
restarts with this fix, where the simulation continues on the same as
|
|
if no restart had taken place. However, in a statistical sense, a
|
|
restarted simulation should produce the same behavior.
|
|
</P>
|
|
<P>The <A HREF = "fix_modify.html">fix_modify</A> <I>temp</I> option is supported by this
|
|
fix. You can use it to assign a temperature <A HREF = "compute.html">compute</A>
|
|
you have defined to this fix which will be used in its thermostatting
|
|
procedure, as described above. For consistency, the group used by
|
|
this fix and by the compute should be the same.
|
|
</P>
|
|
<P>The <A HREF = "fix_modify.html">fix_modify</A> <I>energy</I> option is supported by this
|
|
fix to add the energy change induced by Langevin thermostatting to the
|
|
system's potential energy as part of <A HREF = "thermo_style.html">thermodynamic
|
|
output</A>. Note that use of this option requires
|
|
setting the <I>tally</I> keyword to <I>yes</I>.
|
|
</P>
|
|
<P>This fix computes a global scalar which can be accessed by various
|
|
<A HREF = "Section_howto.html#howto_15">output commands</A>. The scalar is the
|
|
cummulative energy change due to this fix. The scalar value
|
|
calculated by this fix is "extensive". Note that calculation of this
|
|
quantity requires setting the <I>tally</I> keyword to <I>yes</I>.
|
|
</P>
|
|
<P>This fix can ramp its target temperature over multiple runs, using the
|
|
<I>start</I> and <I>stop</I> keywords of the <A HREF = "run.html">run</A> command. See the
|
|
<A HREF = "run.html">run</A> command for details of how to do this.
|
|
</P>
|
|
<P>This fix is not invoked during <A HREF = "minimize.html">energy minimization</A>.
|
|
</P>
|
|
<P><B>Restrictions:</B> none
|
|
</P>
|
|
<P><B>Related commands:</B>
|
|
</P>
|
|
<P><A HREF = "fix_nh.html">fix nvt</A>, <A HREF = "fix_temp_rescale.html">fix temp/rescale</A>, <A HREF = "fix_viscous.html">fix
|
|
viscous</A>, <A HREF = "fix_nh.html">fix nvt</A>, <A HREF = "pair_dpd.html">pair_style
|
|
dpd/tstat</A>
|
|
</P>
|
|
<P><B>Default:</B>
|
|
</P>
|
|
<P>The option defaults are angmom = no, omega = no, scale = 1.0 for all
|
|
types, tally = no, zero = no.
|
|
</P>
|
|
<HR>
|
|
|
|
<A NAME = "Dunweg"></A>
|
|
|
|
<P><B>(Dunweg)</B> Dunweg and Paul, Int J of Modern Physics C, 2, 817-27 (1991).
|
|
</P>
|
|
<A NAME = "Schneider"></A>
|
|
|
|
<P><B>(Schneider)</B> Schneider and Stoll, Phys Rev B, 17, 1302 (1978).
|
|
</P>
|
|
</HTML>
|