lammps/doc/improper_style_hybrid.txt

52 lines
1.6 KiB
Plaintext

"LAMMPS WWW Site"_lws - "LAMMPS Documentation"_ld - "LAMMPS Commands"_lc :c
:link(lws,http://lammps.sandia.gov)
:link(ld,Manual.html)
:link(lc,Section_commands.html#comm)
:line
improper_style hybrid command :h3
[Syntax:]
improper_style hybrid style1 style2 ... :pre
style1,style2 = list of one or more improper styles :ul
[Examples:]
improper_style hybrid harmonic helix
improper_coeff 1 harmonic 120.0 30
improper_coeff 2 cvff 20.0 -1 2 :pre
[Description:]
The {hybrid} style enables the use of multiple improper styles in one
simulation. An improper style is assigned to each improper type. For
example, impropers in a polymer flow (of improper type 1) could be
computed with a {harmonic} potential and impropers in the wall
boundary (of improper type 2) could be computed with a {cvff}
potential. The assignment of improper type to style is made via the
"improper_coeff"_improper_coeff.html command or in the data file.
In the improper_coeff command, the first coefficient sets the improper
style and the remaining coefficients are those appropriate to that
style. In the example above, the 2 improper_coeff commands would set
impropers of improper type 1 to be computed with a {harmonic}
potential with coefficients 120.0, 30 for K, X0. Improper type 2
would be computed with a {cvff} potential with coefficients 20.0, -1,
2 for K, d, n.
An improper style of {none} can be specified as an argument to
improper_style hybrid and the corresponding improper_coeff commands,
if you desire to turn off certain improper types.
[Restrictions:] none
[Related commands:]
"improper_coeff"_improper_coeff.html
[Default:] none