lammps/doc/improper_style_hybrid.txt

55 lines
1.7 KiB
Plaintext
Raw Normal View History

"LAMMPS WWW Site"_lws - "LAMMPS Documentation"_ld - "LAMMPS Commands"_lc :c
:link(lws,http://lammps.sandia.gov)
:link(ld,Manual.html)
:link(lc,Section_commands.html#comm)
:line
improper_style hybrid command :h3
[Syntax:]
improper_style hybrid style1 style2 ... :pre
style1,style2 = list of one or more improper styles :ul
[Examples:]
improper_style hybrid harmonic helix
improper_coeff 1 harmonic 120.0 30
improper_coeff 2 cvff 20.0 -1 2 :pre
[Description:]
The {hybrid} style enables the use of multiple improper styles in one
simulation. An improper style is assigned to each improper type. For
example, impropers in a polymer flow (of improper type 1) could be
computed with a {harmonic} potential and impropers in the wall
boundary (of improper type 2) could be computed with a {cvff}
potential. The assignment of improper type to style is made via the
"improper_coeff"_improper_coeff.html command or in the data file.
In the improper_coeff command, the first coefficient sets the improper
style and the remaining coefficients are those appropriate to that
style. In the example above, the 2 improper_coeff commands would set
impropers of improper type 1 to be computed with a {harmonic}
potential with coefficients 120.0, 30 for K, X0. Improper type 2
would be computed with a {cvff} potential with coefficients 20.0, -1,
2 for K, d, n.
[Restrictions:]
Improper styles can only be set for atom styles that allow impropers to be
defined.
This improper style is part of the "molecular" package. It is only
enabled if LAMMPS was built with that package. See the "Making
LAMMPS"_Section_start.html#2_2 section for more info.
[Related commands:]
"improper_coeff"_improper_coeff.html
[Default:] none