What: /sys/bus/iio/devices/triggerX/trigger_polarity
|
|
KernelVersion: 4.11
|
|
Contact: fabrice.gasnier@st.com
|
|
Description:
|
|
The STM32 ADC can be configured to use external trigger sources
|
|
(e.g. timers, pwm or exti gpio). Then, it can be tuned to start
|
|
conversions on external trigger by either:
|
|
- "rising-edge"
|
|
- "falling-edge"
|
|
- "both-edges".
|
|
Reading returns current trigger polarity.
|
|
Writing value before enabling conversions sets trigger polarity.
|
|
|
|
What: /sys/bus/iio/devices/triggerX/trigger_polarity_available
|
|
KernelVersion: 4.11
|
|
Contact: fabrice.gasnier@st.com
|
|
Description:
|
|
List all available trigger_polarity settings.
|