For devices from the SigmaDelta family we need to keep CS low when doing a
conversion, since the device will use the MISO line as a interrupt to
indicate that the conversion is complete.
This is why the driver locks the SPI bus and when the SPI bus is locked
keeps as long as a conversion is going on. The current implementation gets
one small detail wrong though. CS is only de-asserted after the SPI bus is
unlocked. This means it is possible for a different SPI device on the same
bus to send a message which would be wrongfully be addressed to the
SigmaDelta device as well. Make sure that the last SPI transfer that is
done while holding the SPI bus lock de-asserts the CS signal.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Alexandru Ardelean <Alexandru.Ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>