Synopsys DesignWare SPI master
|
|
|
|
Required properties:
|
|
- compatible: should be "snps,designware-spi"
|
|
- #address-cells: see spi-bus.txt
|
|
- #size-cells: see spi-bus.txt
|
|
- reg: address and length of the spi master registers
|
|
- interrupts: should contain one interrupt
|
|
- clocks: spi clock phandle
|
|
- num-cs: see spi-bus.txt
|
|
|
|
Optional properties:
|
|
- cs-gpios: see spi-bus.txt
|
|
|
|
Example:
|
|
|
|
spi: spi@4020a000 {
|
|
compatible = "snps,designware-spi";
|
|
interrupts = <11 1>;
|
|
reg = <0x4020a000 0x1000>;
|
|
clocks = <&pclk>;
|
|
num-cs = <2>;
|
|
cs-gpios = <&banka 0 0>;
|
|
};
|