Freescale i.MX PWM controller
|
|
|
|
Required properties:
|
|
- compatible: should be "fsl,<soc>-pwm"
|
|
- reg: physical base address and length of the controller's registers
|
|
- #pwm-cells: should be 2. The first cell specifies the per-chip index
|
|
of the PWM to use and the second cell is the period in nanoseconds.
|
|
- interrupts: The interrupt for the pwm controller
|
|
|
|
Example:
|
|
|
|
pwm1: pwm@53fb4000 {
|
|
#pwm-cells = <2>;
|
|
compatible = "fsl,imx53-pwm", "fsl,imx27-pwm";
|
|
reg = <0x53fb4000 0x4000>;
|
|
interrupts = <61>;
|
|
};
|