What: /sys/bus/iio/devices/triggerX/master_mode_available
KernelVersion: 4.11
Contact: benjamin.gaignard@st.com
Description:
Reading returns the list possible master modes which are:
- "reset" : The UG bit from the TIMx_EGR register is
used as trigger output (TRGO).
- "enable" : The Counter Enable signal CNT_EN is used
as trigger output.
- "update" : The update event is selected as trigger output.
For instance a master timer can then be used
as a prescaler for a slave timer.
- "compare_pulse" : The trigger output send a positive pulse
when the CC1IF flag is to be set.
- "OC1REF" : OC1REF signal is used as trigger output.
- "OC2REF" : OC2REF signal is used as trigger output.
- "OC3REF" : OC3REF signal is used as trigger output.
- "OC4REF" : OC4REF signal is used as trigger output.
Additional modes (on TRGO2 only):
- "OC5REF" : OC5REF signal is used as trigger output.
- "OC6REF" : OC6REF signal is used as trigger output.
- "compare_pulse_OC4REF":
OC4REF rising or falling edges generate pulses.
- "compare_pulse_OC6REF":
OC6REF rising or falling edges generate pulses.
- "compare_pulse_OC4REF_r_or_OC6REF_r":
OC4REF or OC6REF rising edges generate pulses.
- "compare_pulse_OC4REF_r_or_OC6REF_f":
OC4REF rising or OC6REF falling edges generate pulses.
- "compare_pulse_OC5REF_r_or_OC6REF_r":
OC5REF or OC6REF rising edges generate pulses.
- "compare_pulse_OC5REF_r_or_OC6REF_f":
OC5REF rising or OC6REF falling edges generate pulses.
+-----------+ +-------------+ +---------+
| Prescaler +-> | Counter | +-> | Master | TRGO(2)
+-----------+ +--+--------+-+ |-> | Control +-->
| | || +---------+
+--v--------+-+ OCxREF || +---------+
| Chx compare +----------> | Output | ChX
+-----------+-+ | | Control +-->
. | | +---------+
. | | .
+-----------v-+ OC6REF | .
| Ch6 compare +---------+>
+-------------+
Example with: "compare_pulse_OC4REF_r_or_OC6REF_r":
X
X X
X . . X
X . . X
X . . X
count X . . . . X
. . . .
. . . .
+---------------+
OC4REF | . . |
+-+ . . +-+
. +---+ .
OC6REF . | | .
+-------+ +-------+
+-+ +-+
TRGO2 | | | |
+-+ +---+ +---------+
What: /sys/bus/iio/devices/triggerX/master_mode
KernelVersion: 4.11
Contact: benjamin.gaignard@st.com
Description:
Reading returns the current master modes.
Writing set the master mode
What: /sys/bus/iio/devices/triggerX/sampling_frequency
KernelVersion: 4.11
Contact: benjamin.gaignard@st.com
Description:
Reading returns the current sampling frequency.
Writing an value different of 0 set and start sampling.
Writing 0 stop sampling.
What: /sys/bus/iio/devices/iio:deviceX/in_count0_preset
KernelVersion: 4.12
Contact: benjamin.gaignard@st.com
Description:
Reading returns the current preset value.
Writing sets the preset value.
When counting up the counter starts from 0 and fires an
event when reach preset value.
When counting down the counter start from preset value
and fire event when reach 0.
What: /sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available
KernelVersion: 4.12
Contact: benjamin.gaignard@st.com
Description:
Reading returns the list possible quadrature modes.
What: /sys/bus/iio/devices/iio:deviceX/in_count0_quadrature_mode
KernelVersion: 4.12
Contact: benjamin.gaignard@st.com
Description:
Configure the device counter quadrature modes:
channel_A:
Encoder A input servers as the count input and B as
the UP/DOWN direction control input.
channel_B:
Encoder B input serves as the count input and A as
the UP/DOWN direction control input.
quadrature:
Encoder A and B inputs are mixed to get direction
and count with a scale of 0.25.
What: /sys/bus/iio/devices/iio:deviceX/in_count_enable_mode_available
KernelVersion: 4.12
Contact: benjamin.gaignard@st.com
Description:
Reading returns the list possible enable modes.
What: /sys/bus/iio/devices/iio:deviceX/in_count0_enable_mode
KernelVersion: 4.12
Contact: benjamin.gaignard@st.com
Description:
Configure the device counter enable modes, in all case
counting direction is set by in_count0_count_direction
attribute and the counter is clocked by the internal clock.
always:
Counter is always ON.
gated:
Counting is enabled when connected trigger signal
level is high else counting is disabled.
triggered:
Counting is enabled on rising edge of the connected
trigger, and remains enabled for the duration of this
selected mode.
What: /sys/bus/iio/devices/iio:deviceX/in_count_trigger_mode_available
KernelVersion: 4.13
Contact: benjamin.gaignard@st.com
Description:
Reading returns the list possible trigger modes.
What: /sys/bus/iio/devices/iio:deviceX/in_count0_trigger_mode
KernelVersion: 4.13
Contact: benjamin.gaignard@st.com
Description:
Configure the device counter trigger mode
counting direction is set by in_count0_count_direction
attribute and the counter is clocked by the connected trigger