57 lines
1.9 KiB
Plaintext
57 lines
1.9 KiB
Plaintext
What: /sys/bus/platform/devices/ci_hdrc.0/inputs/a_bus_req
|
|
Date: Feb 2014
|
|
Contact: Li Jun <b47624@freescale.com>
|
|
Description:
|
|
Can be set and read.
|
|
Set a_bus_req(A-device bus request) input to be 1 if
|
|
the application running on the A-device wants to use the bus,
|
|
and to be 0 when the application no longer wants to use
|
|
the bus(or wants to work as peripheral). a_bus_req can also
|
|
be set to 1 by kernel in response to remote wakeup signaling
|
|
from the B-device, the A-device should decide to resume the bus.
|
|
|
|
Valid values are "1" and "0".
|
|
|
|
Reading: returns 1 if the application running on the A-device
|
|
is using the bus as host role, otherwise 0.
|
|
|
|
What: /sys/bus/platform/devices/ci_hdrc.0/inputs/a_bus_drop
|
|
Date: Feb 2014
|
|
Contact: Li Jun <b47624@freescale.com>
|
|
Description:
|
|
Can be set and read
|
|
The a_bus_drop(A-device bus drop) input is 1 when the
|
|
application running on the A-device wants to power down
|
|
the bus, and is 0 otherwise, When a_bus_drop is 1, then
|
|
the a_bus_req shall be 0.
|
|
|
|
Valid values are "1" and "0".
|
|
|
|
Reading: returns 1 if the bus is off(vbus is turned off) by
|
|
A-device, otherwise 0.
|
|
|
|
What: /sys/bus/platform/devices/ci_hdrc.0/inputs/b_bus_req
|
|
Date: Feb 2014
|
|
Contact: Li Jun <b47624@freescale.com>
|
|
Description:
|
|
Can be set and read.
|
|
The b_bus_req(B-device bus request) input is 1 during the time
|
|
that the application running on the B-device wants to use the
|
|
bus as host, and is 0 when the application no longer wants to
|
|
work as host and decides to switch back to be peripheral.
|
|
|
|
Valid values are "1" and "0".
|
|
|
|
Reading: returns if the application running on the B device
|
|
is using the bus as host role, otherwise 0.
|
|
|
|
What: /sys/bus/platform/devices/ci_hdrc.0/inputs/a_clr_err
|
|
Date: Feb 2014
|
|
Contact: Li Jun <b47624@freescale.com>
|
|
Description:
|
|
Only can be set.
|
|
The a_clr_err(A-device Vbus error clear) input is used to clear
|
|
vbus error, then A-device will power down the bus.
|
|
|
|
Valid value is "1"
|