Commit Graph

13 Commits

Author SHA1 Message Date
Jonghwa Lee 856ee6115e charger-manager: Support deivce tree in charger manager driver
Charger-manager can parse charger_desc data from devicetree which is used
to register charger manager.

Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
2013-12-23 17:10:07 -08:00
Jonghwa Lee 5c49a6256b charger-manager: Modify the way of checking battery's temperature
Charger-manager driver used to check battery temperature through the
callback function passed by platform data. Unfortunatley, without that
pre-defined callback function, charger-manager can't get battery's
temperature at all. Also passing callback function through platform data
ruins DT support for charger-manager.

This patch mondifies charger-manager driver to get temperature of battery
without pre-defined callback function. Now, charger-manager can use either
of battery thermometer in fuel-gauge and ouside of battery. It uses
thermal framework interface for outer thermometer if thermal fw is
enabled. Otherwise, it tries to use fuel-gauge's through the power supply
interface.

Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
2013-12-23 17:09:09 -08:00
Chanwoo Choi 3950c7865c charger-manager: Add support sysfs entry for charger
This patch add support sysfs entry for each charger(regulator).
Charger-manager use one or more chargers for charging battery but some
charger isn't necessary on specific scenario. So, if some charger isn't
needed, can disable specific charger through 'externally_control' entry
while system is on state and confirm the information(name, state) of
charger.

The list of added sysfs entry
- /sys/class/power_supply/battery/chargers/charger.[index]/name
  show name of charger(regulator)
- /sys/class/power_supply/battery/chargers/charger.[index]/state
  show either enabled or disabled state of charger
- /sys/class/power_supply/battery/chargers/charger.[index]/externally_control

If 'externally_control' of specific charger is 1, Charger-manager cannot
enable regulator for charging when charger cable is attached and charger
must be maintained with disabled state. If 'externally_control' is zero,
Charger-manager usually can control to enable/disable regulator.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-09-21 16:32:40 -07:00
Chanwoo Choi 8fcfe088e2 charger-manager: Support limit of maximum possible
This patch check maximum possible duration of charging/discharging.

If whole charging duration exceed 'desc->charging_max_duration_ms', cm
stop charging to prevent overcharge/overheat. And if discharging duration
exceed, charger cable is attached, after full-batt, cm start charging to
maintain fully charged state for battery.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-09-20 22:08:00 -07:00
Chanwoo Choi 2ed9e9b653 charger-manager: Check fully charged state of battery periodically
This patch check periodically fully charged state of battery to protect
overcharge and overheat. If battery is fully charged, stop charging and
check droped voltage with 'fullbatt_vchkdrop_ms' period. When voltage of
battery is more droped than 'fullbatt_vchkdrop_uV' voltage,
charger-manager will restart charging for battery.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-09-20 22:07:49 -07:00
Anton Vorontsov c6b2744c5d charger-manager: Fix struct charger_desc's misleading comment
The comment says that charger_regulators is an array of
regulator_bulk_data, which is not true, since it's actually a pointer
to 'struct charger_regulator'.

Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-08-22 21:49:35 -07:00
Chanwoo Choi fd65ee5f1c charger-manager: Use replacement variable to check state of battery
This patch remove unnecessary variable(cm->fullbatt_vchk_uV) by using
'desc->fullbatt_uV' field directly in fullbatt_handler() function
to check the state of battery.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-08-22 20:09:08 -07:00
Chanwoo Choi 45cd4fb28b charger-manager: Set current limit of regulator for over current protection
This patch support the protection of host device from over current.
The Charger-manager set proper current limit of charger(regulator) for
charging according to type of charger cable when external connector
is attached.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-07-13 18:31:17 -07:00
Chanwoo Choi bee737bccb charger-manager: Use EXTCON Subsystem to detect charger cables for charging
This patch support that charger-manager use EXTCON(External Connector)
Subsystem to detect the state of charger cables for enabling or disabling
charger(regulator) and select the charger cable for charging among
a number of external cable according to policy of H/W board.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-07-13 18:31:13 -07:00
Chanwoo Choi dfeccb12b4 charger-manager: Provide cm_notify_event function for in-kernel use
By using cm_notify_event function, charger driver can report several
charger events (e.g. battery full and external power in/out, etc) to
Charger-Manager. Charger-Manager can properly and immediately control
chargers by the reported event.

Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-05-05 19:51:58 -07:00
Chanwoo Choi d829dc75ba charger-manager: Poll battery health in normal state
Charger-Manager needs to check battery health in normal state
as well as suspend-to-RAM state. When the battery is fully charged,
Charger-Manager needs to determine when the chargers restart charging.

This patch allows Charger-Manager to monitor battery health in normal
state and handle operation for chargers after battery is fully charged.

Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-05-05 19:48:50 -07:00
Donggeun Kim ad3d13eee7 power_supply: Charger-Manager: Add properties for power-supply-class
Charger Manager provides power-supply-class aggregating
information from multiple chargers and a fuel-gauge.

Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-01-04 08:08:45 +04:00
Donggeun Kim 3bb3dbbd56 power_supply: Add initial Charger-Manager driver
Because battery health monitoring should be done even when suspended,
it needs to wake up and suspend periodically. Thus, userspace battery
monitoring may incur too much overhead; every device and task is woken
up periodically. Charger Manager uses suspend-again to provide
in-suspend monitoring.

This patch allows to monitor battery health in-suspend state.

Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-01-04 08:08:27 +04:00