Commit Graph

3 Commits

Author SHA1 Message Date
Takashi Sakamoto 7e1621de14 ALSA: firewire-lib/bebob/oxfw: improve response evaluation for AV/C commands
In ALSA firewire stack, some AV/C commands are supported, including
vendor's extensions. Drivers includes response parser of each command,
according to its requirements, while the parser is written with loose
fashion in two points; error check and length check. This doesn't cause
any issues such as kernel corruption, but should be improved.

This commit modifies evaluations of return value on each parsers.

Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
2017-04-05 21:37:23 +02:00
Takashi Sakamoto 1fc9522a08 ALSA: bebob: Prepare for device specific operations
This commit is for some devices which have its own operations or quirks.

Many functionality should be implemented in user land. Then this commit adds
functionality related to stream such as sampling frequency or clock source. For
help to debug, this commit adds the functionality to get metering information
if it's available.

To help these functionalities, this commit adds some AV/C commands defined in
'AV/C Audio Subunit Specification (1394TA).

Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
2014-05-26 14:31:15 +02:00
Takashi Sakamoto eb7b3a056c ALSA: bebob: Add commands and connections/streams management
This commit adds management functionality for connections and streams.
BeBoB uses CMP to manage connections and uses AMDTP for streams.

This commit also adds some BridgeCo's AV/C extension commands. There are some
BridgeCo's AV/C extension commands but this commit just uses below commands
to get device's capability and status:

 1.Extended Plug Info commands
  - Plug Channel Position Specific Data
  - Plug Type Specific Data
  - Cluster(Section) Info Specific Data
  - Plug Input Specific Data
 2.Extended Stream Format Information commands
  - Extended Stream Format Information Command - List Request

For Extended Plug Info commands for Cluster Info Specific Data, I pick up
'section' instead of 'cluster' from document to prevent from misunderstanding
because 'cluster' is also used in IEC 61883-6.

Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
2014-05-26 14:29:29 +02:00