Various SCSI trace enhancements:
- Display data and protection information scatterlist lengths in the
trace output
- Add support for VERIFY and WRITE SAME commands and decode the UNMAP
bit if applicable
- Add decoding of the PROTECT field for READ/VERIFY/WRITE/WRITE SAME
commands as well as the EXPECTED INITIAL REFERENCE TAG field for
their 32-byte variants
- Decode READ CAPACITY(16), GET LBA STATUS, and UNMAP
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
__print_hex() prints values in an array in hex (w/o '0x') (space separated)
EX) 92 33 32 f3 ee 4d
Signed-off-by: Li Zefan <lizf@cn.fujitsu.com>
Signed-off-by: Tomohiro Kusumi <kusumi.tomohiro@jp.fujitsu.com>
Signed-off-by: Kei Tokunaga <tokunaga.keiich@jp.fujitsu.com>
Acked-by: Steven Rostedt <rostedt@goodmis.org>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add definitions for VERIFY(12) and VERIFY(32).
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add a few clarifying comments in the B0 page function and allow the
optimal transfer length field to be specified on the command line using
opt_blks=N.
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch adds a bunch of fixes
1. Reduce sg table size to 64 (SG_MX) instead of default SG_ALL
2. clear task lists on phy down events
3. release all tasks on port deformation
4. release current task for device gone notification
5. Add sata abort handing
6. Add 10ms delay to each port reset (currently done serially and with
interrupts disabled)
[jejb: whitespace fixes and clean ups plus added description
added dummy 94xx_clear_srs_irq function just to prevent the
mismatch in the mvs_dispatch structure killing 94xx cards]
Signed-off-by: Srinivas <satyasrinivasp@hcl.in>
Cc: Andy Yan <ayan@marvell.com>
Cc: qswang@marvell.com
Cc: jfeng@marvell.com
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
iscsi_conn is not used so remove it from iscsi_sw_tcp_conn.
Signed-off-by: Avi Kaplan <savik751@gmail.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch changes the arguments to iscsi_sw_tcp_conn_restore_callbacks,
so that it works like the function to set the callbacks and because
in upcoming patches we need a iscsi_conn.
Signed-off-by: Avi Kaplan <savik751@gmail.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
blk_get_request sets the cmd_flags, so we should not and do not
need to set them. If we did set them to a different value then
it can cause a oops in the elevator code.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This change is basically a clean up.
datadgst_en is an int which comes from the user. I didn't see anything
limiting it to 1 and 0 although obviously that's what it's supposed to
be. If the user passed in 2 this test would fail.
This same if condition is repeated in another function and it uses &&
there.
Signed-off-by: Dan Carpenter <error27@gmail.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Print all world wide node names (node, port and fabric) with the same
format specifier of "%16.16llx". That makes sure they all print as a
16 character hex string, with lower case letters, no 0x prefix, and
without stripping off any leading 0s.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Most of the prints of fabric IDs were specified as %6x, which will not
print any leading 0s. It's nice to see leading 0s for identifiers
like this, which are a fixed length. This patch sets the precision
modifier as well, making the specifier %6.6x, which forces the
printing of leading 0s.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
fc_fcp_resp is assuming when FCP_SNS_LEN_VAL is set, the FCP_RSP_LEN_VAL
is not, which is not true. This leads to not copying the sense data and
error out a valid FCP_RSP.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
No reason to restrict CDB size to 12 bytes in fcoe, so
increased to 16 so that 16 bytes SCSI CDB doesn't fail.
Uses common define to set max_cmd_len for fcoe and fnic,
fnic is already setting max_cmd_len to 16.
sg_readcap -l fails without this fix.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
fnic_flush_tx() is used to send frames held while fabric login
is in progress. The frames are held in tx_queue, but
fnic_flush_tx() was incorrectly flushing from recv_queue which
is used for received frames.
Signed-off-by: Brian Uchino <buchino@cisco.com>
Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
New fnic version to mark inclusion of tx_flush bugfix.
Signed-off-by: Brian Uchino <buchino@cisco.com>
Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
hton24(p + 3, value) would fail to compile because
p + 3[0] is not a valid expression.
Went ahead and converted hton24 and ntoh24 to inline
functions, which is better because the parameters
are evalutated only once.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
fc_exch_recv_req has variables eof, sof, and f_ctl,
which are set but never used. Delete them.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Allow for dormant states while link configuration completes.
In the default link mode, this is equivalent to the old check.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The FIP controler state wasn't being reset on a disable.
A disable/enable sequence should be treated as a link event.
Otherwise, when using disable to mask a time when the link
is up but unusable, FCF discovery would attempt to continue
and login would jump directly to the non-FIP fallback on
enable.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
FPMA indicates that the Fabric will provide the host's
N_Port's MAC address. When sending a FLOGI/FDISC frame
and FPMA was negotiated through FIP discovery we still
need to provide the MAC descriptor, as per the
specification, but the MAC should be zero'd out since
the FCF will be providing it in the FLOGI/FDISC ACC.
In FC-BB-5 section 7.8.7.4.2 (Fabric login) it states:
The MAC address field in the MAC address descriptor of a FIP FLOGI
Request operation or a FIP NPIV FDISC Request operation shall contain:
a) the proposed MAC address to use as VN_Port MAC address if the ENode
is requesting to use SPMA (see table 27);
b) all zeroes to indicate no MAC address is proposed if the ENode is
requesting to use FPMA (see table 27); or
c) the proposed MAC address to use as VN_Port MAC address if the ENode
supports both SPMA and FPMA and leaves the decision of which
addressing scheme to use to the FCF (i.e., if both the FP and SP
bits are set to one, see table 27).
This patch fixes case B.
This patch also adds debug statements to illustrate
whether a FPMA or SPMA MAC is added to a FLOGI/FDISC
frame.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Fix a oops in _scsih_sas_device_remove. The driver was attempting to
delete a object from the sas_device link list when the object was not
present.
Added sanity check for sas_device NULL dereference.
before deleting sas_device now driver will search device in list then
only it will follow device removal.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
we added support to set the deleted flag prior to device scan,
then clear the flag for responding devices, leaving the deleted flag only
set for missing devices. The problem is for internal generated host resets,
IO queues are not blocked at scsi mid layer level. IO will be continued
sent to driver, and driver will return SCSI_MLQUEUE_HOST_BUSY. The problem
is the driver checks for the deleted flag before it checks for the
controller being in reset, so there is a window where the driver would be
returning DID_NO_CONNECT for responding devices. This occurs during the
time between calling _scsih_prep_device_scan, and
_scsih_mark_responding_sas_device & _scsih_mark_responding_raid_device.
Fix the queuecommand entry point so ioc->shost_recovery flag sanity check is
given higher presidence then the device "deleted flag" check.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Add code to prevent unreg_vpi mailbox command from failing.
- Add code to reset the HBA if unreg_vpi mailbox fails with busy status.
- Remove code that was clearing the nlp_type stored during rport discovery.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Add memcpy to mailbox completion to transfer reply correctly.
- Add support for BSG mailbox commands (dump, update_cfg, and
event_log_status).
- Add warning message and refuse mailbox command while mgmt is blocked.
- Add checks for memory allocation failure.
- Add check for sli4 dump zero BDE size.
- Only copy data if mailbox commands succeed.
- Add support for Read Event Log mailbox command.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Move the code to increase the sg seg count for LP21000 adapters.
- Check pcmd on command completion before dereferencing it.
- Clear queue memory when creating firmware queues to prevent stale entries.
- Replace the use of PAGE_SIZE in many areas that assumed it was always 4k.
- Add an else clause to a conditional that needed to unlock the hba_lock.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Update driver for change in T10-PI interface on adapter
- Remove Profiles.
- Add new SLI Opcodes.
- Add new PDE structures used for BlockGuard.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Prevent log message 1801 during vport delete.
- Enable NPIV by default.
- Display correct value for max Vports on SLI4 HBAs.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Add the new Logical Link speed event support.
- Add RATOV and EDTOV to the REG_VFI mailbox command.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Added check before free_pages just to make sure ioc->scsi_lookup is not NULL.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Added support in the driver to support EEH and
PCIe Advanced Error Recovery. This involves adding new
pci_error_handler interface for recovering the controller from PCI Bus
errors, such as SERR and PERR. Some tools are available for simulating
PCI errors in order to validate this interface:
http://www.kernel.org/pub/linux/utils/pci/aer-inject
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
RAID_SCSI_IO_PASSTHROUGH: Driver needs to be sending the default
descriptor for RAID Passthru, currently its sending SCSI_IO descriptor.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
There are few special cases which needs to be handled deleting old port.
CASE1: In topology you need cascaded expanders. Through sysfs just make sure
topology is up. Erase the manufacturing image of the cascaded expander and
reset the board. In some cases Adapter will receive Exapnder Add event
before expander delete. In such a case, driver needs to delete duplicate
port before adding new port.
CASE2: Enable Device Missing delay of HBA through lsiutils. If expander or
end device is hotswapped with different device before DMD timer expires,
driver will get device add for new device first and then device deletion
event for the original devices will arrive later at DMD timer expires. In
this case also driver need to delete duplicate port before adding port for
new device.
Added new function which will make sure when new port is
added, that its not claiming the same phy resources already in use by
another port. If it does, then it will delete the other port before adding
the new port.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
While testing the midlevel q_at_head and q_at_tail
patch for sg and the block SG_IO ioctl I found it
useful to reduce the queuing within the scsi_debug
driver. The reason is that the midlevel queue only
comes into play when the corresponding LLD queue
is full.
It is also useful when testing to be confident that
your program is the only thing issuing commands
to the (virtual) scsi_debug device. The no_uld=1
parameter will stop a scsi_debug virtual disk
appearing as /dev/sd* .
Changelog:
- add max_queue parameter to reduce the number
of queued commands the driver will accept.
This parameter can be changed after the driver
is loaded.
- add no_uld parameter that restricts scsi_debug's
virtual devices to the sg and bsg drivers
- correct stale url
Signed-off-by: Douglas Gilbert <dgilbert@interlog.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Hazard testing uncovered yet another bug in sd. Under heavy reset
activity the retry counter might be exhausted and the command will be
returned with sense UNIT_ATTENTION/0x29/00 (POWER ON, RESET, OR BUS
DEVICE RESET OCCURRED). In those cases we should just increase the
retry counter again, retrying one more to clear up this Unit Attention
state.
[jejb: update to work with RC16 devices and not to loop endlessly]
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
After Host Reset firmware will have new list of device handles for the target.
Device handle refresh in driver is part of Rescan topology logic.
(See functions like *_search_responding_*). This needs to be done from Host
Reset context before making shost_recovery to 0. Currently it is done in
Firwmare event context, which may leads IO to a wrong device.
Now handler refresh is moved to HBA reset context.
Apart from this, Now driver will stop IOs for all device setting deleted
flag to 1 at the time of HBA Reset through _scsih_prep_device_scan.
It will only unblock devices, if devices has been found as part of RESCAN.
This way it will make more safe IO blocking at the time of HBA reset at
mpt2sas driver layer.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
sd always tries to submit a READ_CAPACITY(16) CDB,
regardless whether the host actually supports it.
queuecommand() will then return DID_ABORT, which is
not qualified enough to detect the true cause here.
So better check in sd_try_rc16 first if the cdblen
is supported.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When bnx2/cnic/bnx2i drivers are loaded in certain order, bnx2i will
will not initialize the device correctly because 'hba->cnic' will be
NULL when bnx2i_start() is called from register_device() context.
Under this condition 'ifdown' and 'ifup' of associated network
interface is required to bring iscsi adapter state to ready state so
that it will accept iscsi connection setup within the chip
Initializing 'hba->cnic' before calling register_device() will fix
this issue
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
instruct firmware to use driver/iscsid provided expected statsn field
while constructing login pdu header.
Initialize 'flags' to instruct chip to use driver/iscsid provided
ExpStatSN value while constructing iSCSI login PDU header
Signed-off-by: Eddie Wai <waie@broadcom.com>
Signed-off-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The return code FAST_IO_FAIL from fc_block_scsi_eh indicates that the
pending I/O requests have been terminated as a result of the
fast_io_fail_tmo. Pass this return code back to the scsi eh to stop
the scsi eh in this case.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
If the scsi eh is running and then a FC LLD calls
fc_remote_port_delete, the SCSI commands sent from the eh will fail.
To prevent this, a FC LLD can call fc_block_scsi_eh from the eh
callback, blocking the eh thread until the dev_loss_tmo fires or the
remote port is available again.
If (e.g. for a multipathing setup) the dev_loss_tmo is set to a very
large value, thus preventing the scsi device removal , the scsi eh can
block for a long time. For multipathing, the fast_io_fail_tmo is then
set to a low value to detect path problems sooner.
This patch introduces a new return code FAST_IO_FAIL. The function
fc_block_scsi_eh now returns FAST_IO_FAIL when the fast_io_fail_tmo
fires. This indicates that the LLD terminated all pending I/O requests
and there are no more pending SCSI commands for the scsi eh to wait
for. This return code can be passed back to the scsi eh to stop the
escalation and finish the recovery process for this device.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The default is enabled since 7e47e5ca18.
Signed-off-by: Ferenc Wagner <wferi@niif.hu>
Acked-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The qla84xx_mgmt_cmd function supports multiple subcommands.
Some subcommands require DMA memory and some do not.
Therefore check before freeing DMA memory whether it is allocated or not.
Signed-off-by: Harish Zunjarrao <harish.zunjarrao@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>