The RTC core is always calling rtc_valid_tm after the read_time callback.
It is not necessary to call it just before returning from the callback.
Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
The err variable is not being reset after a successful read. Explicitly
return 0 at the end of function call to account for all return paths.
Reported-by: Jens-Peter Oswald <oswald@lre.de>
Signed-off-by: Akshay Bhat <akshay.bhat@timesys.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
The driver doesn't have a struct of_device_id table but supported devices
are registered via Device Trees. This is working on the assumption that a
I2C device registered via OF will always match a legacy I2C device ID and
that the MODALIAS reported will always be of the form i2c:<device>.
But this could change in the future so the correct approach is to have an
OF device ID table if the devices are registered via OF.
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Since commit d68778b80d ("rtc: initialize output parameter for read
alarm to "uninitialized"") there is no need to explicitly set
unsupported members to -1. So drop the respective assignments from
drivers.
Signed-off-by: Uwe Kleine-König <uwe@kleine-koenig.org>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
This driver supports the following functions:
- reading and setting time
- alarms when connected to an IRQ
- reading and clearing the voltage low flags
Datasheet:
http://www.epsondevice.com/docs/qd/en/DownloadServlet?id=ID000956
Signed-off-by: Akshay Bhat <akshay.bhat@timesys.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>