Each of the if-else blocks has a break statement. Remove the additional
one which is unreachable.
Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Check the return value of regulator_enable to silence the following
type of warnings:
drivers/power/ab8500_charger.c:1390:20: warning: ignoring return value
of ‘regulator_enable’, declared with attribute warn_unused_result
[-Wunused-result]
Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
There is a missing break statement here, so we print an error message that
the USB type is invalid. The original code still works fine though except
for the error message.
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
The driver core clears the driver data to NULL after device_release or on
probe failure, since commit 0998d06310
(device-core: Ensure drvdata = NULL when no driver is bound). Thus, it is
not needed to manually clear the device driver data to NULL.
Signed-off-by: Jingoo Han <jg1.han@samsung.com>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
There's no need to test whether a (delayed) work item is pending
before queueing, flushing or cancelling it. Most uses are unnecessary
and quite a few of them are buggy.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Only AB8500 has this hardware bug, so these works only need to be run
there.
Signed-off-by: Rabin Vincent <rabin.vincent@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: Martin SJOBLOM <martin.w.sjoblom@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
When the state of USB Charge detection is changed then the calls
use a define for another register in other bank. This change
creates a new define for the correct register and removes the
magic numbers that are present.
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Hakan BERG <hakan.berg@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
The newer AB's such as the AB8505, AB9540 etc include a
USBLink1 Status register which detects a larger range of
external devices. This should be used instead of the
USBLine Status register.
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Hakan BERG <hakan.berg@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Tested-by: Yang QU <yang.qu@stericsson.com>
Provide AB8540 platform specific information required to run the
Battery Management subsystem on AB8540 based devices. For this to
happen we see the introduction of separate platform specific data
structures and a means in which to process them.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
AB8540 supports power path function in USB charging mode for fast
power up with dead and weak battery, and it could extend
the battery age.
When USB charging starts, if the Vbattrue is below than SW cut off
voltage, power path and pre-charge should be enabled. If Vbattrue
is higher than SW cut off voltage, power path and pre-charge should
be disabled. This is to make sure full current to battery charge.
At the end of charge, power path should be enable again to reduce
charging the battery again.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
The PM2301 Charger should always be available when using the AB8500
Battery Management system, we're ensuring this will be the case.
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Hakan BERG <hakan.berg@stericsson.com>
Reviewed-by: Mian Yousaf KAUKAB <mian.yousaf.kaukab@stericsson.com>
The AB8505 does not have the same address for USB link-status
as has ab8500. Add AB8505_USB_LINK_STATUS and code to switch
to correct constant.
Signed-off-by: Hakan Berg <hakan.berg@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Mian Yousaf KAUKAB <mian.yousaf.kaukab@stericsson.com>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: Rabin VINCENT <rabin.vincent@stericsson.com>
Do not set higher current in stepping functionality if VBUS is dropping.
After VBUS has dropped try to set current once again. If dropping again
then we have found the maximum capability of the charger.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Due to a bug in some AB8500 ASICs charger removal cannot always
be detected if the removal and reinsertion is done to close in time.
This patch detects above described case and handles the situation
so that charging will be kept turned on.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Add 2.7v, 2.9v, 3.0v, 3.2v and 3.3v charging voltages for backup
battery. Before that only 2.5v, 2.6v, 2.8v, 3.1v were available.
Signed-off-by: Yang QU <yang.qu@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Maxime COQUELIN <maxime.coquelin@stericsson.com>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Tested-by: Xiao Mei ZHANG <xiaomei.zhang@stericsson.com>
If charging is started before USB enumeration of an Accessory
Charger Adapter has finished, the AB8500 will generate a
VBUS_ERROR. This in turn results in timeouts and delays the
enumeration with around 15 seconds. This patch delays the
charging and then ramps currents slowly to avoid VBUS errors.
The delay allows the enumeration to have finished before
charging is turned on.
Signed-off-by: Martin Sjoblom <martin.w.sjoblom@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Tested-by: Jonas ABERG <jonas.aberg@stericsson.com>
None of the aforementioned components have their own dedicated
platform data structures anymore. Instead they have all been
merged into one big Battery Management container. Let's remove
them and place all the nice newly added attributes into the core
container.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Do not touch the VBUSOVV in USBCHTRL2 when running on AB8505.
Signed-off-by: Jonas Aaberg <jonas.aberg@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Tested-by: Mian Yousaf KAUKAB <mian.yousaf.kaukab@stericsson.com>
Flush all workqueues at suspend time to avoid suspending during work.
Signed-off-by: Jonas Aaberg <jonas.aberg@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Accessing autopower register fails on the AB8505 and ab9540 as
the fallback software control register has moved.
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Mattias WALLIN <mattias.wallin@stericsson.com>
Reviewed-by: Nicolas GUION <nicolas.guion@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Tested-by: Jonas ABERG <jonas.aberg@stericsson.com>
AB and PMxxx doesn't have same watchdog refresh period. Add watchdog
to refresh period parameters in x500 charger structure, this should
kick watchdog every 30sec. The AC charging should also kick both
pm2xxx and the AB charger watchdog.
Signed-off-by: Rajkumar Kasirajan <rajkumar.kasirajan@stericsson.com>
Signed-off-by: Loic Pallardy <loic.pallardy@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Michel JAOUEN <michel.jaouen@stericsson.com>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Tested-by: Michel JAOUEN <michel.jaouen@stericsson.com>
Tested-by: Jonas ABERG <jonas.aberg@stericsson.com>
AB8500 refuses to start charging when some types of non standard
chargers are connected. This change force the AB to start charging.
Signed-off-by: Henrik Sölver <henrik.solver@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Yvan FILLION <yvan.fillion@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Tested-by: Yvan FILLION <yvan.fillion@stericsson.com>
AC charger driver for the DB9540 based platforms.
Signed-off-by: Rajkumar Kasirajan <rajkumar.kasirajan@stericsson.com>
Signed-off-by: Loic Pallardy <loic.pallardy@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Michel JAOUEN <michel.jaouen@stericsson.com>
Tested-by: Michel JAOUEN <michel.jaouen@stericsson.com>
A Legacy USB charger should be handled directly by the charger
driver.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Reviewed-by: Karl KOMIEROWSKI <karl.komierowski@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Cleanup of the ab8500_charger driver.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Reviewed-by: Karl KOMIEROWSKI <karl.komierowski@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
The Travel and Carkit adapter should be handled directly by
the charger driver.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Gracefully handle gpadc conversion errors.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Jonas Aaberg <jonas.aberg@stericsson.com>
Reviewed-by: Johan BJORNSTEDT <johan.bjornstedt@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Add two new work queues to provide USB and AC charger disconnect
detection.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Rename the ab8500_power_loss_handling function to a more
descriptive name ab8500_enable_disable_sw_fallback
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Robert Marklund <robert.marklund@stericsson.com>
Reviewed-by: Par-Olof HAKANSSON <par-olof.hakansson@stericsson.com>
Reviewed-by: Karl KOMIEROWSKI <karl.komierowski@stericsson.com>
Tested-by: Par-Olof HAKANSSON <par-olof.hakansson@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
The merge is merely to fix conflicts before sending a pull request.
Conflicts:
drivers/power/ab8500_btemp.c
drivers/power/ab8500_charger.c
drivers/power/ab8500_fg.c
drivers/power/abx500_chargalg.c
drivers/power/max8925_power.c
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Now that we always pass platform specific battery management data
through platform_data instead of obtaining it via different means
depending the way be boot the system (DT or ATAGs); we need to
re-jiggle the way we acquire it in the driver start-up functions.
Now it is wrong for it to be missing, but we still allow Device
Tree code to fiddle with it once we've confirmed it's there.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Currently the AB8500 battery management subsystem receives platform
specific information via two different means depending on how the
platform is booted. If DT is not enabled, a reference to a *_bm_data
data structure containing each platform specific attribute is passed
though platform_data. However, if DT is enabled, then platform_data
is empty and the reference is gained though a DT specific probe
function. There are two issues here 1) the same reference is
being collected each time and 2) the DT way doesn't allow any
provisions to select different platform specific attributes, which
kind of defeats the object.
Cc: Samuel Ortiz <sameo@linux.intel.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
The platform specific battery management configuration data structure
is currently called 'bat' short for 'battery'; however, it contains
information for all components of the battery management group, rather
than information pertaining to the battery itself - there are other
structures for that. So, in keeping with its structure namesake
'abx500_bm_data', we rename it to 'bm' here. Using similar logic,
we're also renaming 'bmdevs_of_probe' to the more device specific
'ab8500_bm_of_probe'.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
There is no state machine in the AB to step up/down the charger
current to avoid dips and spikes on VBUS and VBAT when charging
is started. Instead this is implemented in SW.
Signed-off-by: Johan Bjornstedt <johan.bjornstedt@stericsson.com>
Signed-off-by: Mattias Wallin <mattias.wallin@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Karl KOMIEROWSKI <karl.komierowski@stericsson.com>
CONFIG_HOTPLUG is going away as an option so __devexit is no
longer needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Cc: Anton Vorontsov <cbou@mail.ru>
Cc: David Woodhouse <dwmw2@infradead.org>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
CONFIG_HOTPLUG is going away as an option so __devinit is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Cc: Anton Vorontsov <cbou@mail.ru>
Cc: David Woodhouse <dwmw2@infradead.org>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
CONFIG_HOTPLUG is going away as an option so __devexit_p is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Cc: Anton Vorontsov <cbou@mail.ru>
Cc: David Woodhouse <dwmw2@infradead.org>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This patch adds device tree support for ab8500-charger driver
Signed-off-by: Rajanikanth H.V <rajanikanth.hv@stericsson.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
- This patch adds device tree support for fuelgauge driver
- optimize bm devices platform_data usage and of_probe(...)
Note: of_probe() routine for battery managed devices is made
common across all bm drivers.
- test status:
- interrupt numbers assigned differs between legacy and FDT mode.
Signed-off-by: Rajanikanth H.V <rajanikanth.hv@stericsson.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
- Marvell 88pm860x charger and battery drivers;
- Texas Instruments LP8788 charger driver;
2. Two new power supply properties: whether a battery is authentic, and
chargers' maximal currents and voltages;
3. A lot of TI LP8727 Charger cleanups;
4. New features for Charger Manager, mainly now we can disable specific
regulators;
5. Random fixes and cleanups for other drivers.
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v2.0.19 (GNU/Linux)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=LkdH
-----END PGP SIGNATURE-----
Merge tag 'for-v3.7' of git://git.infradead.org/battery-2.6
Pull battery updates from Anton Vorontsov:
"1. New drivers:
- Marvell 88pm860x charger and battery drivers;
- Texas Instruments LP8788 charger driver;
2. Two new power supply properties: whether a battery is authentic,
and chargers' maximal currents and voltages;
3. A lot of TI LP8727 Charger cleanups;
4. New features for Charger Manager, mainly now we can disable
specific regulators;
5. Random fixes and cleanups for other drivers."
Fix up trivial conflicts in <linux/mfd/88pm860x.h>
* tag 'for-v3.7' of git://git.infradead.org/battery-2.6: (52 commits)
pda_power: Remove ac_draw_failed goto and label
charger-manager: Add support sysfs entry for charger
charger-manager: Support limit of maximum possible
charger-manager: Check fully charged state of battery periodically
lp8727_charger: More pure cosmetic improvements
lp8727_charger: Fix checkpatch warning
lp8727_charger: Add description in the private data
lp8727_charger: Fix a typo - chg_parm to chg_param
lp8727_charger: Make some cosmetic changes in lp8727_delayed_func()
lp8727_charger: Clean up lp8727_charger_changed()
lp8727_charger: Return if the battery is discharging
lp8727_charger: Make lp8727_charger_get_propery() simpler
lp8727_charger: Make lp8727_ctrl_switch() inline
lp8727_charger: Make lp8727_init_device() shorter
lp8727_charger: Clean up lp8727_is_charger_attached()
lp8727_charger: Use specific definition
lp8727_charger: Clean up lp8727 definitions
lp8727_charger: Use the definition rather than enum
lp8727_charger: Fix code for getting battery temp
lp8727_charger: Clear interrrupts at inital time
...
Initialize return variable before exiting on an error path.
A simplified version of the semantic match that finds this problem is as
follows: (http://coccinelle.lip6.fr/)
// <smpl>
(
if@p1 (\(ret < 0\|ret != 0\))
{ ... return ret; }
|
ret@p1 = 0
)
... when != ret = e1
when != &ret
*if(...)
{
... when != ret = e2
when forall
return ret;
}
// </smpl>
Signed-off-by: Julia Lawall <Julia.Lawall@lip6.fr>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Initalizers for deferrable delayed_work are confused.
* __DEFERRED_WORK_INITIALIZER()
* DECLARE_DEFERRED_WORK()
* INIT_DELAYED_WORK_DEFERRABLE()
Rename them to
* __DEFERRABLE_WORK_INITIALIZER()
* DECLARE_DEFERRABLE_WORK()
* INIT_DEFERRABLE_WORK()
This patch doesn't cause any functional changes.
Signed-off-by: Tejun Heo <tj@kernel.org>
usb_get_phy will return -ENODEV if it's not able to find the phy. Hence
fixed all the callers of usb_get_phy to check for this error condition
instead of relying on a non-zero value as success condition.
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Felipe Balbi <balbi@ti.com>