F54 diagnostics report functions provide data based on the number of
enabled rx and tx electrodes, which is not identical to the number of
electrodes reported with F54:Query0 and F54:Query1. Those values report
the number of supported electrodes, not the number of enabled electrodes.
The number of enabled electrodes can be determined by analyzing F55:Ctrl1
(sensor receiver assignment) and F55:Ctrl2 (sensor transmitter assignment).
Propagate the number of enabled electrodes from F55 to F54 to avoid
corrupted output if not all electrodes are enabled.
Fixes: 3a762dbd53 ("[media] Input: synaptics-rmi4 - add support for F54 ...")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Tested-by: Nick Dyer <nick@shmanahar.org>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Sensor tuning support is needed to determine the number of enabled
tx and rx electrodes for use in F54 functions.
The number of enabled electrodes is not identical to the total number
of electrodes as reported with F55:Query0 and F55:Query1. It has to be
calculated by analyzing F55:Ctrl1 (sensor receiver assignment) and
F55:Ctrl2 (sensor transmitter assignment).
Support for additional sensor tuning functions may be added later.
Fixes: 3a762dbd53 ("[media] Input: synaptics-rmi4 - add support for F54 ...")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Tested-by: Nick Dyer <nick@shmanahar.org>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>