Commit Graph

2 Commits

Author SHA1 Message Date
Joachim Eastwood 2a9a06f98f clk: lpc18xx-ccu: fix potential system hang when disabling unused clocks
CCU branch clock register must only be accessed while the base
(parent) clock is running. Access with a disabled base clock
will cause the system to hang. Fix this issue by adding code
that check if the parent clock is running in the is_enabled
clk_ops callback.

This hang would occur when disabling unused clocks after AMBA
runtime pm had already disabled some of the clocks.

Signed-off-by: Joachim Eastwood <manabian@gmail.com>
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
2015-10-26 12:36:56 -07:00
Joachim Eastwood 472cd304a3 clk: add lpc18xx ccu clk driver
Add driver for NXP LPC18xx/43xx Clock Control Unit (CCU). The CCU
provides fine grained gating of most clocks present in the SoC.

Signed-off-by: Joachim Eastwood <manabian@gmail.com>
Signed-off-by: Michael Turquette <mturquette@baylibre.com>
2015-06-18 15:44:48 -07:00