If we are in non-bypass mode then the SYSCLK is required for full charge
pump operation, otherwise we will fall back to bypass mode. Use the DAPM
context exposed by the ASoC driver to manage this.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
CONFIG_HOTPLUG is going away as an option so __devexit is no
longer needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
CONFIG_HOTPLUG is going away as an option so __devinit is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
CONFIG_HOTPLUG is going away as an option so __devexit_p is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
If min_uV is in the range of: 3250001~3269999,
current code uses the equation:
selector = DIV_ROUND_UP(min_uV - 1700000, 50000);
Then selector will be 32.
Then arizona_micsupp_list_voltage returns -EINVAL for this case which is wrong.
This patch fixes this issue:
If min_uV > 3200000, selector should be ARIZONA_MICSUPP_MAX_SELECTOR.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The Wolfson Arizona platform is used for a range of low power audio hub
CODECs. Many of these devices feature an integrated power supply for the
microphone which is supported by this driver.