This wasn't explained well anywhere and should be clearly specified. Lets add a
top level comment for this.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
cooling_cpufreq_lock isn't used to protect this structure and so the comment
over it is outdated. Fix it.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
In this patch, the cpu_cooling code checks for the usability of cpufreq
layer before proceeding with the CPU cooling device registration. The
main reason is: CPU cooling device is not usable if cpufreq cannot
switch frequencies.
Similar checks are spread in thermal drivers. Thus, the advantage now
is to have the check in a single place: cpu cooling device registration.
For this reason, this patch also updates the existing drivers that
depend on CPU cooling to simply propagate the error code of the cpu
cooling registration call. Therefore, in case cpufreq is not ready, the
thermal drivers will still return -EPROBE_DEFER, in an attempt to try
again when cpufreq layer gets ready.
Cc: devicetree@vger.kernel.org
Cc: Grant Likely <grant.likely@linaro.org>
Cc: Kukjin Kim <kgene.kim@samsung.com>
Cc: linux-arm-kernel@lists.infradead.org
Cc: linux-kernel@vger.kernel.org
Cc: linux-pm@vger.kernel.org
Cc: linux-samsung-soc@vger.kernel.org
Cc: Naveen Krishna Chatradhi <ch.naveen@samsung.com>
Cc: Rob Herring <robh+dt@kernel.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Existing code updates cupfreq policy only while executing
cpufreq_apply_cooling() function (i.e. when notify_device != NOTIFY_INVALID).
It doesn't apply constraints when cpufreq policy update happens from any other
place but it should update the cpufreq policy with thermal constraints every
time when there is a cpufreq policy update, to keep state of
cpufreq_cooling_device and max_feq of cpufreq policy in sync. For instance
while resuming cpufreq updates cpufreq_policy and it restores default
policy->usr_policy values irrespective of cooling device's cpufreq_state since
notification gets missed because (notify_device == NOTIFY_INVALID).
Another problem, is that userspace is able to change max_freq irrespective of
cooling device's state, as notification gets missed.
This patch modifies code to maintain a global cpufreq_dev_list and applies
constraints of all matching cooling devices for policy's cpu when there is any
policy update(ends up applying the lowest max_freq among the matching cpu
cooling devices).
This patch also removes redundant check (max_freq > policy->user_policy.max),
as cpufreq framework takes care of user_policy constraints already where ever
required, otherwise its causing an issue while increasing max_freq in normal
scenerio as it restores max_freq with policy->user_policy.max which is old
(smaller) value.
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
The cpufreq core now supports the cpufreq_for_each_valid_entry macro
helper for iteration over the cpufreq_frequency_table, so use it.
Also remove the redundant !! operator.
It should have no functional changes.
Signed-off-by: Stratos Karafotis <stratosk@semaphore.gr>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
As per Documentation/thermal/sysfs-api.txt, max_level
is an index, not a counter. Thus, in case a CPU has
3 valid frequencies, max_level is expected to be 2, for instance.
The current code makes max_level == number of valid frequencies,
which is bogus. This patch fix the cpu_cooling device by
ranging max_level properly.
Reported-by: Carlos Hernandez <ceh@ti.com>
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This patch introduces an API to register cpufreq cooling device
based on device tree node.
The registration via device tree node differs from normal
registration due to the fact that it is needed to fill
the device_node structure in order to be able to match
the cooling devices with trip points.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
In case of error, the function thermal_cooling_device_register() returns
ERR_PTR() and never returns NULL. The NULL test in the return value check
should be replaced with IS_ERR().
Signed-off-by: Wei Yongjun <yongjun_wei@trendmicro.com.cn>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This patch avoids NULL pointer accesses while unregistering
cpu cooling devices, in case a NULL pointer is received.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
cpufreq_thermal_notifier() is to change the cpu's cpufreq in the allowed_cpus mask
when associated thermal-cpufreq cdev's cooling state is changed. It's a cpufreq policy
notifier handler and it will be triggered even if those cpus out of allowed_cpus has
changed freq policy.
cpufreq_thermal_notifier() checks the policy->cpu. If it belongs to allowed_cpus,
change max_freq(default to 0) to the desire cpufreq value and pass 0 and max_freq
to cpufreq_verify_within_limits() as cpufreq scope. But if not, do nothing and
max_freq will remain 0. This will cause the cpufreq scope to become 0~0. This
is not right. This patch is to return directly after finding cpu not belonging
to allowed_cpus.
Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
The variable 'descend' is initialized as -1 in function get_property(),
and will never get any chance to be updated by the following code.
if (freq != CPUFREQ_ENTRY_INVALID && descend != -1)
descend = !!(freq > table[i].frequency);
This makes function get_property() return the wrong frequency for given
cooling level if the frequency table is sorted in ascending. Fix it
by correcting the 'descend' check in if-condition to 'descend == -1'.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Improve code readiness by changing alignments so that
they match open parenthesis, like checkpatch.pl --strict
suggests.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
There are at least three patterns for oneline comments in this
file. This patch changes them to one single pattern
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Just for code readiness, this patch makes all functions
on this file to have a blank line before their returns.
Now, some functions follow this pattern, and others will
not have a blank line. So, this patch makes it a single
pattern.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
The list is not needed so far. Thus removing it.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Just for style purposes, remove extra curl brackets.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Limit the amount of bytes written to dev_name by
secure writing with snprintf.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Update comments for this exported function.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Add proper documentation for exported function cpufreq_cooling_register.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Update kernel-doc comment and documentation for cpufreq_thermal_notifier.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Add documentation for cpufreq_get_cooling_level. As this
is an exported function, it has to be documented.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
As this is one of the central functions of this file,
it deserves a proper documentation. This patch improves
the existing comment to format it as a kernel-doc style.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Update documentation for is_cpufreq_valid function so
that kernel-doc does not complain about return value.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
level will be used only if GET_FREQ mode is requested.
There is no potential harm with current code. But for
cleaning the compilation log, this patch initializes
level to zero.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Restrict the usage to GPL modules.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Simple fixes for making kernel_doc happy about
struct cpufreq_cooling_device. Includes also a minor
spelling fix.
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This code doesn't work on big endian systems because we're storing low
values in the high bits of the unsigned long. It makes it a very high
value instead.
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
cpufreq cooling uses different frequencies as different cooling states.
But the per_cpu cpufreq_frequency_table may contain duplicate,
invalid entries, and it may be in either ascending or descending order.
And currently, code for parsing the per_cpu cpufreq_frequency_table
is used in several places and inconsistent.
Now introduce new code to
1. get the maximum cooling states
2. translate cooling state to cpu frequency
3. translate cpu frequency to cooling state
in one place,
with the correct logic of handling per_cpu cpufreq_frequency_table.
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Tested-by: Amit Daniel kachhap <amit.daniel@samsung.com>
Pull thermal management updates from Zhang Rui:
"Highlights:
- introduction of Dove thermal sensor driver.
- introduction of Kirkwood thermal sensor driver.
- introduction of intel_powerclamp thermal cooling device driver.
- add interrupt and DT support for rcar thermal driver.
- add thermal emulation support which allows platform thermal driver
to do software/hardware emulation for thermal issues."
* 'release' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (36 commits)
thermal: rcar: remove __devinitconst
thermal: return an error on failure to register thermal class
Thermal: rename thermal governor Kconfig option to avoid generic naming
thermal: exynos: Use the new thermal trend type for quick cooling action.
Thermal: exynos: Add support for temperature falling interrupt.
Thermal: Dove: Add Themal sensor support for Dove.
thermal: Add support for the thermal sensor on Kirkwood SoCs
thermal: rcar: add Device Tree support
thermal: rcar: remove machine_power_off() from rcar_thermal_notify()
thermal: rcar: add interrupt support
thermal: rcar: add read/write functions for common/priv data
thermal: rcar: multi channel support
thermal: rcar: use mutex lock instead of spin lock
thermal: rcar: enable CPCTL to use hardware TSC deciding
thermal: rcar: use parenthesis on macro
Thermal: fix a build warning when CONFIG_THERMAL_EMULATION cleared
Thermal: fix a wrong comment
thermal: sysfs: Add a new sysfs node emul_temp for thermal emulation
PM: intel_powerclamp: off by one in start_power_clamp()
thermal: exynos: Miscellaneous fixes to support falling threshold interrupt
...
Convert to the much saner new idr interface.
Signed-off-by: Tejun Heo <tj@kernel.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
"level" parameter of get_cpu_frequency equals cooling state
of cpu cooling device, and it starts from 0.
Fix the misleading comment.
Signed-off-by: Zhang Rui <rui.zhang@intel.com>