Commit Graph

7 Commits

Author SHA1 Message Date
Martin Schwidefsky b38feccd66 s390: remove runtime instrumentation interrupts
The external interrupts for runtime instrumentation buffer-full
and runtime instrumentation halted are unused and have no current
user. Remove the support and ignore the second parameter of the
s390_runtime_instr system call from now on.

Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2015-11-03 14:40:51 +01:00
Thomas Huth 1dad093b66 s390/irq: Use defines for external interruption codes
Use the new defines for external interruption codes to get rid
of "magic" numbers in the s390 source code. And while we're at it,
also rename the (un-)register_external_interrupt function to
something shorter so that this patch does not exceed the 80
columns all over the place.

Signed-off-by: Thomas Huth <thuth@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2014-04-03 14:30:52 +02:00
Martin Schwidefsky e258d719ff s390/uaccess: always run the kernel in home space
Simplify the uaccess code by removing the user_mode=home option.
The kernel will now always run in the home space mode.

Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2013-10-24 17:16:57 +02:00
Heiko Carstens 82003c3e60 s390/irq: rework irq subclass handling
Let's not add a function for every external interrupt subclass for
which we need reference counting. Just have two register/unregister
functions which have a subclass parameter:

void irq_subclass_register(enum irq_subclass subclass);
void irq_subclass_unregister(enum irq_subclass subclass);

Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
2013-09-04 17:19:13 +02:00
Heiko Carstens 420f42ecf4 s390/irq: remove split irq fields from /proc/stat
Now that irq sum accounting for /proc/stat's "intr" line works again we
have the oddity that the sum field (first field) contains only the sum
of the second (external irqs) and third field (I/O interrupts).
The reason for that is that these two fields are already sums of all other
fields. So if we would sum up everything we would count every interrupt
twice.
This is broken since the split interrupt accounting was merged two years
ago: 052ff461c8 "[S390] irq: have detailed
statistics for interrupt types".
To fix this remove the split interrupt fields from /proc/stat's "intr"
line again and only have them in /proc/interrupts.

This restores the old behaviour, seems to be the only sane fix and mimics
a behaviour from other architectures where /proc/interrupts also contains
more than /proc/stat's "intr" line does.

Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2013-01-08 10:57:07 +01:00
Heiko Carstens d1b0d842c4 s390/mm: rename addressing_mode to s390_user_mode
Renaming the globally visible variable "user_mode" to "addressing_mode" in
order to fix a name clash was not a good idea. (Commit 37fe1d73 "s390/mm:
rename user_mode variable to addressing_mode")
Looking at the code after a couple of weeks one thinks: addressing mode of
what?
So rename the variable again. This time to s390_user_mode. Which hopefully
makes more sense.

Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2012-09-26 15:45:05 +02:00
Jan Glauber e4b8b3f33f s390: add support for runtime instrumentation
Allow user-space threads to use runtime instrumentation (RI). To enable RI
for a thread there is a new s390 specific system call, sys_s390_runtime_instr,
that takes as parameter a realtime signal number. If the RI facility is
available the system call sets up a control block for the calling thread with
the appropriate permissions for the thread to modify the control block.

The user-space thread can then use the store and modify RI instructions to
alter the control block and start/stop the instrumentation via RION/RIOFF.

If the user specified program buffer runs full RI triggers an external
interrupt. The external interrupt is translated to a real-time signal that
is delivered to the thread that enabled RI on that CPU. The number of
the real-time signal is the number specified in the RI system call. So,
user-space can select any available real-time signal number in case the
application itself uses real-time signals for other purposes.

The kernel saves the RI control blocks on task switch only if the running
thread was enabled for RI. Therefore, the performance impact on task switch
should be negligible if RI is not used.

RI is only enabled for user-space mode and is disabled for the supervisor
state.

Reviewed-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Jan Glauber <jang@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2012-09-26 15:45:02 +02:00