MAX30102 is an heart rate and pulse oximeter sensor that works using
two LEDS of different wavelengths, and detecting the light reflected
back.
This patchset adds support for both IR and RED LED channels which can
be processed in userspace to determine heart rate and blood oxygen
levels. The MAX30102 part isn't completely register and functional
compatible with the existing MAX30100 driver.
Signed-off-by: Matt Ranostay <matt@ranostay.consulting>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The newly added afe4403 driver uses the regmap facility to abstract
the I2C and SPI access. However, it fails to ensure that regmap_spi
is actually present:
drivers/iio/built-in.o: In function `afe4403_probe':
:(.text+0x9bf8): undefined reference to `__devm_regmap_init_spi'
This adds a Kconfig select statement like the afe4404 I2C driver
has.
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Fixes: eec96d1e2d ("iio: health: Add driver for the TI AFE4403 heart monitor")
Acked-by: Andrew F. Davis <afd@ti.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add driver for the TI AFE4403 heart rate monitor and pulse oximeter.
This device detects reflected LED light fluctuations and presents an ADC
value to the user space for further signal processing.
Data sheet located here:
http://www.ti.com/product/AFE4403/datasheet
Signed-off-by: Andrew F. Davis <afd@ti.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add driver for the TI AFE4404 heart rate monitor and pulse oximeter.
This device detects reflected LED light fluctuations and presents an ADC
value to the user space for further signal processing.
Datasheet: http://www.ti.com/product/AFE4404/datasheet
Signed-off-by: Andrew F. Davis <afd@ti.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
MAX30100 is an heart rate and pulse oximeter sensor that works using
two LEDS of different wavelengths, and detecting the light reflected
back.
This patchset adds support for both IR and RED LED channels which can
be processed in userspace to determine heart rate and blood oxygen
levels.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>