commit 8b63ec1837 ("phylib: Make PHYs children of their MDIO bus,
not the bus' parent.") changed the parenting of PHY devices, making
them a child of the MDIO bus, instead of the MAC device. This broken
the Micrel PHY driver which has a deprecated feature of allowing PHY
properties to be placed into the MAC node.
In order to find the MAC node, we need to walk up the tree of devices
until we find one with an OF node attached.
Reported-by: Dinh Nguyen <dinguyen@opensource.altera.com>
Suggested-by: David Daney <david.daney@cavium.com>
Acked-by: David Daney <david.daney@cavium.com>
Fixes: 8b63ec1837 ("phylib: Make PHYs children of their MDIO bus, not the bus' parent.")
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Tested-by: Dinh Nguyen <dinguyen@opensource.altera.com>
Acked-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Very rarely, the KSZ9031 will appear to complete autonegotiation, but
will drop all traffic afterwards. When this happens, the idle error
count will read 0xFF after autonegotiation completes. Reset the PHY
when in that state.
Signed-off-by: Nathan Sullivan <nathan.sullivan@ni.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Link failures have been observed when using the KSZ9031 with HP 1810-8G
and HP 1910-8G network switches. Center the FLP timing at 16ms to help
avoid intermittent link failures.
>From the KSZ9031RNX and KSZ9031MNX data sheets revision 2.2, section
"Auto-Negotiation Timing":
The KSZ9031[RNX or MNX] Fast Link Pulse (FLP) burst-to-burst
transmit timing for Auto-Negotiation defaults to 8ms. IEEE 802.3
Standard specifies this timing to be 16ms +/-8ms. Some PHY link
partners need to receive the FLP with 16ms centered timing;
otherwise, there can be intermittent link failures and long
link-up times.
The PHY data sheet recommends configuring the FLP burst registers after
power-up/reset and immediately thereafter restarting auto-negotiation, so
we center the FLP timing at 16ms and then restart auto-negotiation in the
config_init for KSZ9031.
Signed-off-by: Jaeden Amero <jaeden.amero@ni.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are some defines for a few pad skew related extended registers.
Specify for which MMD Address (dev_addr) they are for.
Signed-off-by: Jaeden Amero <jaeden.amero@ni.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In a few places in this driver, we weren't using const where we could
have. Use const more.
In addition, change the arrays of strings in ksz9031_config_init() to be
not only const, but also static.
Signed-off-by: Jaeden Amero <jaeden.amero@ni.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Don't do clock-mode-select if clk == NULL,
since when building without CONFIG_HAVE_CLK,
clk_get returns NULL and clk_get_rate returns 0.
Doing clock-mode-select in this cause causes kszphy_probe to
return -EINVAL and thus prevents the device from being probed.
The original code (before regression) would return 0
when building without CONFIG_HAVE_CLK.
Cc: stable <stable@vger.kernel.org> # 3.18+
Fixes: 1fadee0c36 ("net/phy: micrel: Add clock support for
KSZ8021/KSZ8031")
Reviewed-by: Fabio Estevam <fabio.estevam@freescale.com>
Reviewed-by: Johan Hovold <johan@kernel.org>
Signed-off-by: Niklas Cassel <niklass@axis.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
NAND-tree is used to check wiring between MAC and PHY using NAND gates
on the PHY side, hence the name.
NAND-tree initial status is latched at reset by probing the IRQ pin.
However some devices are sharing the PHY IRQ pin with other peripherals
such as Atmel SAMA5D[34]x-EK boards when using the optional TM7000
display module, therefore they are switching the PHY in NAND-tree test
mode depending on the current IRQ line status at reset.
This patch ensure PHY is not in NAND-tree test mode for all Micrel PHYs
using IRQ line as a NAND-tree toggle mode at reset.
Signed-off-by: Sylvain Rochet <sylvain.rochet@finsecur.com>
Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Use generic config_init callback also for KSZ8021 and KSZ8031.
This has been avoided this far due to commit b838b4aced ("phy/micrel:
KSZ8031RNL RMII clock reconfiguration bug"), which claims that the PHY
becomes unresponsive if the broadcast-disable flag is set before
configuring the clock mode.
Turns out that the problem seemingly worked-around by the above
mentioned commit was really due to a hardware-configuration issue, where
the PHY was in fact strapped to address 3 rather than 0.
Tested-by: Bruno Thomsen <bth@kamstrup.dk>
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add generic interrupt-config callback and store interrupt-level bitmask
in type data for PHY types not using bit 9.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Micrel KSZ8081 and KSZ8091 PHYs have the RMII Reference Clock Select
bit, which is used to select 25 or 50 MHz clock mode.
Note that on some revisions of the PHY (e.g. KSZ8081RND) the function of
this bit is inverted so that setting it enables 25 rather than 50 MHz
mode. Add a new device-tree property
"micrel,rmii-reference-clock-select-25-mhz" to describe this.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add generic RMII-Reference-Clock-Select support.
Several Micrel PHY have an RMII-Reference-Clock-Select bit to select
25 MHz or 50 MHz clock mode. Recently, support for configuring this
through device tree for KSZ8021 and KSZ8031 was added.
Generalise this support so that it can be configured for other PHY types
as well.
Note that some PHY revisions (of the same type) has this bit inverted.
This should be either configurable through a new device-tree property,
or preferably, determined based on PHY ID if possible.
Also note that this removes support for setting 25 MHz mode from board
files which was also added by the above mentioned commit 45f56cb82e45
("net/phy: micrel: Add clock support for KSZ8021/KSZ8031").
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add has_broadcast_disable flag to type-data and generic config_init.
This allows us to remove the ksz8081 config_init callback.
Note that ksz8021_config_init is kept for now due to a95a18afe4c8
("phy/micrel: KSZ8031RNL RMII clock reconfiguration bug").
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Parse the "micrel,led-mode" property at probe, rather than at config_init
time in the led-setup helper itself.
Note that the bogus parent->of_node bit is removed.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add structured device-type information and support for generic led-mode
setup to the generic config_init callback.
This is a first step in ultimately getting rid of device-type specific
callbacks.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Enable led-mode configuration for KSZ8081 and KSZ8091.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Clean up led-mode setup by introducing proper defines for PHY Control
registers 1 and 2 and only passing the register to the setup function.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Make sure never to update more than two bits when setting the led mode,
something which could for example change the reference-clock setting.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Disable PHY address 0 as the broadcast address, so that it can be used
as a unique (non-broadcast) address on a shared bus.
Note that this can also be configured using the B-CAST_OFF pin on
KSZ9091, but that KSZ8081 lacks this pin and is also limited to
addresses 0 and 3.
Specifically, this allows for dual KSZ8081 setups.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Refactor and clean up broadcast disable.
Some Micrel PHYs have a broadcast-off bit in the Operation Mode Strap
Override register which can be used to disable PHY address 0 as the
broadcast address, so that it can be used as a unique (non-broadcast)
address on a shared bus.
Note that the KSZPHY_OMSO_RMII_OVERRIDE bit is set by default on
KSZ8021/8031.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Make sure never to update the control register with random data (an
error code) by checking the return value after reading it.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Replace module init/exit which only calls phy_drivers_register with
module_phy_driver macro.
Tested using Micrel driver, and otherwise compile-tested only.
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Bug: Unable to send and receive Ethernet packets with Micrel PHY.
Affected devices:
KSZ8031RNL (commercial temp)
KSZ8031RNLI (industrial temp)
Description:
PHY device is correctly detected during probe.
PHY power-up default is 25MHz crystal clock input
and output 50MHz RMII clock to MAC.
Reconfiguration of PHY to input 50MHz RMII clock from MAC
causes PHY to become unresponsive if clock source is changed
after Operation Mode Strap Override (OMSO) register setup.
Cause:
Long lead times on parts where clock setup match circuit design
forces the usage of similar parts with wrong default setup.
Solution:
Swapped KSZ8031 register setup and added phy_write return code validation.
Tested with Freescale i.MX28 Fast Ethernet Controler (fec).
Signed-off-by: Bruno Thomsen <bth@kamstrup.dk>
Signed-off-by: David S. Miller <davem@davemloft.net>
The KSZ8021 and KSZ8031 support RMII reference input clocks of 25MHz
and 50MHz. Both PHYs differ in the default frequency they expect
after reset. If this differs from the actual input clock, then
register 0x1f bit 7 must be changed.
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The KSZ9031 appears to suffer from the same hardware bug as described
for the KSZ9021 in commit 32fcafbcd1
("net/phy: micrel: Disable asymmetric pause for KSZ9021")
you have to unplug the cable and plug it back to get it to work.
Remove the SUPPORTED_Asym_Pause flag for the KSZ9031 to fix this.
Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl>
Signed-off-by: David S. Miller <davem@davemloft.net>
The Micrel ksz9021 PHY does not support standard IEEE standard MMD
extended register access, therefore requires stubs to fail the read
register method and do nothing for the write register method when
libphy attempts to read and/or configure Energy Efficient Ethernet
features in PHYS that do support those features. This problem
was observed on an Altera Cyclone V SOC development kit that
uses the Synopsys EMAC and the Micrel ksz9021 PHY. This patch
was tested on the same board, and Energy Efficient Ethernet is
now disabled as expected since the Micrel PHY does not support that
feature.
Signed-off-by: Vince Bridgers <vbridgers2013@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Adds support for ksz9031 PAD skew configuration over devicetree.
Signed-off-by: Hubert Chaumette <hchaumette@adeneo-embedded.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In ksz9021_load_values_from_of() val2 to val4 aren't tested against their
initialization value.
This causes the test to always succeed, and this value to be used as if it
was loaded from the devicetree instead of being ignored, in case of a
missing/invalid property in the ethernet OF device node.
As a result, the value "0" is written to the relevant registers.
Change the conditions to test against the right initialization value.
Signed-off-by: Hubert Chaumette <hchaumette@adeneo-embedded.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Commit 20d8435a1c (phy: micrel: add of configuration for LED mode) made the
obvious mistake when masking off the LED mode bits: forgot to do a logical NOT
to the mask with which it ANDs the register value, so that unrelated bits are
cleared instead.
Signed-off-by: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com>
Acked-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Acked-by: Ben Dooks <ben.dooks@codethink.co.uk>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add support for the led-mode property for the following PHYs
which have a single LED mode configuration value.
KSZ8001 and KSZ8041 which both use register 0x1e bits 15,14 and
KSZ8021, KSZ8031 and KSZ8051 which use register 0x1f bits 5,4
to control the LED configuration.
Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Conflicts:
drivers/net/ethernet/intel/i40e/i40e_main.c
drivers/net/macvtap.c
Both minor merge hassles, simple overlapping changes.
Signed-off-by: David S. Miller <davem@davemloft.net>
checkpatch spotted a few spaces vs tabs errors, fix them.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Renesas R-Car development boards use KSZ8041RNLI PHY which for some reason has
ID of 0x00221537 that is not documented for KSZ8041-family PHYs and does not
match the documented ID of 0x0022151x (where 'x' is the revision). We have
to add the new #define PHY_ID_* and new ksphy_driver[] entry, almost the same
as KSZ8041 one, differing only in the 'phy_id' and 'name' fields.
Signed-off-by: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com>
Tested-by: Geert Uytterhoeven <geert@linux-m68k.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
All supported Micrel PHYs implement the standard "power down" bit 11 of BMCR,
so this patch adds support using the generic genphy_{suspend,resume} functions.
Signed-off-by: Patrice Vilchez <patrice.vilchez@atmel.com>
[b.brezillon@overkiz.com: adapt to newer kernel and generalize to other phys]
Signed-off-by: Boris BREZILLON <b.brezillon@overkiz.com>
[nicolas.ferre@atmel.com: commit message modification]
Signed-off-by: Nicolas Ferre <nicolas.ferre@atmel.com>
Cc: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Some boards require custom PHY configuration, for example due to trace
length differences. Add the ability to configure these registers in
order to get the PHY to function on boards that need it.
Because PHYs are auto-detected based on MDIO device IDs, allow PHY
configuration to be specified in the parent Ethernet device node if no
PHY device node is present.
Signed-off-by: Sean Cross <xobs@kosagi.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
ksz8873mll_read_status() is used only in this file.
Fix the following sparse warning:
drivers/net/phy/micrel.c:147:5: warning: symbol 'ksz8873mll_read_status' was not declared. Should it be static?
Signed-off-by: Jingoo Han <jg1.han@samsung.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The flag MICREL_PHY_50MHZ_CLK is not of exclusive use of KSZ8051
model. At least KSZ8021 and KSZ8031 models also use it.
This patch moves the handling of this and future flags to a
separate function so that the different PHY models can call it on
their init function, if needed.
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Micrel PHY KSZ8031 is similar to KSZ8021 and also requires the special
initialization of "Operation Mode Strap Override" in reg 0x16
introduced in 212ea99 (phy/micrel: Implement support for KSZ8021).
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
Reviewed-by: Marek Vasut <marex@denx.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Phyter KSZ9021 has hardware bug. If asymmetric pause is enabled,
then it is necessary to disconnect and then reconnect the ethernet
cable to get the phyter working. The solution is to disable the
asymmetric pause.
Signed-off-by: Vlastimil Kosar <ikosar@fit.vutbr.cz>
Signed-off-by: David S. Miller <davem@davemloft.net>
Summary of changes:
.Newly added phys
-KSZ8081/KSZ8091, which has some phy ids.
-KSZ8061
-KSZ9031, which is Gigabit phy.
-KSZ886X, which has a switch function.
-KSZ8031, which has a same phy ids with KSZ8021.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
this will allow to detect the link between the switch and the soc
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
Cc: netdev@vger.kernel.org
Signed-off-by: David S. Miller <davem@davemloft.net>
There is no such part as KS8001, KS8041 or KS8051. There are only
KSZ8001, KSZ8041 and KSZ8051. Rename these parts as such to match
the Micrel naming.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Cc: Linux ARM kernel <linux-arm-kernel@lists.infradead.org>
Cc: Fabio Estevam <fabio.estevam@freescale.com>
Cc: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
The KSZ8021 PHY was previously caught by KS8051, which is not correct.
This PHY needs additional setup if it is strapped for address 0. In such
case an reserved bit must be written in the 0x16, "Operation Mode Strap
Override" register. According to the KS8051 datasheet, that bit means
"PHY Address 0 in non-broadcast" and it indeed behaves as such on KSZ8021.
The issue where the ethernet controller (Freescale FEC) did not communicate
with network is fixed by writing this bit as 1.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If registering of one of them fails, all already registered drivers
of this module will be unregistered.
Use the new register/unregister functions in all drivers
registering more than one driver.
amd.c, realtek.c: Simplify: directly return registration result.
Tested with broadcom.c
All others compile-tested.
Signed-off-by: Christian Hohnstaedt <chohnstaedt@innominate.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
On a freescale imx6q platform, a hardware phy chip KSZ9021 is
recognized as a KS8001 chip by the current driver like this:
eth0: Freescale FEC PHY driver [Micrel KS8001 or KS8721]
KSZ9021 has phy_id 0x00221610, while KSZ8001 has phy_id
0x0022161a, the current phy_id_mask (0x00fffff0/0x00ffff10) can't
distinguish them. So change phy_id_mask to resolve this problem.
Although the micrel datasheet says that the 4 LSB of phyid2 register
contains the chip revision number and the current driver is designed
to follow this rule, in reality the chip implementation doesn't follow
it.
Cc: David J. Choi <david.choi@micrel.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: Nobuhiro Iwamatsu <nobuhiro.iwamatsu.yj@renesas.com>
Signed-off-by: Hui Wang <jason77.wang@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Platform code can now set the MICREL_PHY_50MHZ_CLK bit of dev_flags in a fixup
routine (registered with phy_register_fixup_for_uid()), to make the KZS8051RNL
PHY work with 50MHz RMII reference clock.
Cc: David J. Choi <david.choi@micrel.com>
Signed-off-by: Baruch Siach <baruch@tkos.co.il>
Signed-off-by: David S. Miller <davem@davemloft.net>
MODULE_DEVICE_TABLE only expands to something if it's compiled
for a module. So when building-in support for the phys, the
mdio_device_id tables are unused. Marking them with __maybe_unused
fixes the following warnings:
drivers/net/phy/bcm63xx.c:134: warning: 'bcm63xx_tbl' defined but not used
drivers/net/phy/broadcom.c:933: warning: 'broadcom_tbl' defined but not used
drivers/net/phy/cicada.c:162: warning: 'cicada_tbl' defined but not used
drivers/net/phy/davicom.c:222: warning: 'davicom_tbl' defined but not used
drivers/net/phy/et1011c.c:114: warning: 'et1011c_tbl' defined but not used
drivers/net/phy/icplus.c:137: warning: 'icplus_tbl' defined but not used
drivers/net/phy/lxt.c:226: warning: 'lxt_tbl' defined but not used
drivers/net/phy/marvell.c:724: warning: 'marvell_tbl' defined but not used
drivers/net/phy/micrel.c:234: warning: 'micrel_tbl' defined but not used
drivers/net/phy/national.c:154: warning: 'ns_tbl' defined but not used
drivers/net/phy/qsemi.c:141: warning: 'qs6612_tbl' defined but not used
drivers/net/phy/realtek.c:82: warning: 'realtek_tbl' defined but not used
drivers/net/phy/smsc.c:257: warning: 'smsc_tbl' defined but not used
drivers/net/phy/ste10Xp.c:135: warning: 'ste10Xp_tbl' defined but not used
drivers/net/phy/vitesse.c:195: warning: 'vitesse_tbl' defined but not used
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Hello all:
This patch fixes what Ben mentioned, namely duplicated ids.
From: David J. Choi <david.choi@micrel.com>
Body of the explanation: This patch has changes as followings;
-support the interrupt from phy devices from Micrel Inc.
-support more phy devices, ks8737, ks8721, ks8041, ks8051 from Micrel.
-remove vsc8201 because this device was used only internal test at Micrel.
Signed-off-by: David J. Choi <david.choi@micrel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>