Viresh Kumar 4843c4a190 thermal: cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
get_property() was an over complicated beast with BUGs. It used to believe that
cpufreq table is present in ascending or descending order, which might not
always be true.

Previous patch has created another freq table in descending order for us and we
better use it now. With that get_property() simply goes away and another helper
get_level() comes in.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:11:54 -04:00
Viresh Kumar f6859014c7 thermal: cpu_cooling: Store frequencies in descending order
CPUFreq framework *doesn't* guarantee that frequencies present in cpufreq table
will be in ascending or descending order. But cpu_cooling somehow assumes that.

Probably because most of current users are creating this list from DT, which is
done with the help of OPP layer. And OPP layer creates the list in ascending
order of frequencies.

But cpu_cooling can be used for other platforms too, which don't have
frequencies arranged in any order.

This patch tries to fix this issue by creating another list of valid frequencies
in descending order. Care is also taken to throw warnings for duplicate entries.

Later patches would use it to simplify code.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:11:02 -04:00
Viresh Kumar b9f8b41603 thermal: cpu_cooling: Pass 'cpufreq_dev' to get_property()
We already know the value of 'cpufreq_dev->max_level' and so there is no need
calculating that once again. For this, we need to send 'cpufreq_dev' to
get_property().

Make all necessary changes for this change. Because cpufreq_cooling_get_level()
doesn't have access to 'cpufreq_dev', it is updated to iterate over the list of
cpufreq_cooling_devices to get cooling device for the cpu number passed to it.
This also makes it robust to return levels only for the CPU registered via a
cooling device. We don't have to support anything that isn't registered yet.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:10:08 -04:00
Viresh Kumar 2479bb6443 thermal: cpu_cooling: use cpufreq_dev_list instead of cpufreq_dev_count
As we already have a list of cpufreq_cooling_devices now, lets use it instead of
a local counter.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:09:15 -04:00
Viresh Kumar 97afa4aafb thermal: cpu_cooling: get_property() doesn't need to support GET_MAXL anymore
We don't use get_property() to find max levels anymore as it is done at boot
now. So, don't support GET_MAXL in get_property().

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:08:05 -04:00
Viresh Kumar dcc6c7fdef thermal: cpu_cooling: find max level during device registration
CPU frequency tables don't update after the driver is registered and so we don't
need to iterate over them to find total number of states every time
cpufreq_get_max_state() is called. Do it once at boot time.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:07:10 -04:00
Viresh Kumar 521a2e5831 thermal: cpu_cooling: remove unnecessary wrapper get_cpu_frequency()
get_cpu_frequency() isn't doing much by itself, just calling get_property(). And
so this wrapper isn't required at all. Get rid of it.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:05:53 -04:00
Viresh Kumar 5194fe4699 thermal: cpu_cooling: Merge cpufreq_apply_cooling() into cpufreq_set_cur_state()
cpufreq_apply_cooling() has a single caller, cpufreq_set_cur_state() and
cpufreq_set_cur_state() is an unnecessary wrapper over cpufreq_apply_cooling().

Get rid of it by merging both routines.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:04:56 -04:00
Viresh Kumar 7adb635b3c thermal: cpu_cooling: initialize 'cpufreq_val' on registration
There is no point checking for validity of 'cpufreq_val' from
cpufreq_thermal_notifier() every time the routine is called. Its guaranteed to
be 0 on the first call but will be valid otherwise.

Lets update it once while the device registers.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:09:52 -04:00
Viresh Kumar 730abe064b thermal: cpu_cooling: do error handling at the bottom in __cpufreq_cooling_register()
This makes life easy and bug free. And is scalable for future resource
allocations.

Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:57 -04:00
Viresh Kumar c9ca319f05 thermal: cpu_cooling: Don't check is_cpufreq_valid()
Because get_cpu_frequency() has returned a valid frequency, it means that the
cpufreq policy is surely valid and so no point checking that again with
is_cpufreq_valid(). Get rid of the routine as well as there are no more users.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:57 -04:00
Viresh Kumar e1fae554fb thermal: cpu_cooling: don't iterate over all allowed_cpus to update cpufreq policy
All CPUs present in 'allowed_cpus' share the same 'struct cpufreq_policy'
structure and so calling cpufreq_update_policy() for each of them doesn't make
sense.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar 405fb82562 thermal: cpu_cooling: Don't match min/max frequencies for all CPUs on cooling register
In __cpufreq_cooling_register() we try to match min/max frequencies for all CPUs
passed in 'clip_cpus' mask. This mask is the cpumask of cpus where the frequency
constraints will be applied.

Same frequency constraint can be applied only to the CPUs belonging to the same
cluster (i.e. CPUs sharing clock line). For all such CPUs we have a single
'struct cpufreq_policy' structure managing them and so getting policies for all
CPUs wouldn't make any sense as they will all return the same pointer.

So, remove this useless check of checking min/max for all CPUs. Also update doc
comment to make this more obvious that clip_cpus should be same as
policy->related_cpus.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar 268ac445ee thermal: cpu_cooling: propagate error returned by idr_alloc()
We aren't supposed to return our own error type here. Return what we got.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar 8e54d442fe thermal: cpu_cooling: no need to initialze 'ret'
ret is initialized before it is used, so no need to set it to 0 in its declaration.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar 5d3bdb8998 thermal: cpu_cooling: no need to set cpufreq_dev to NULL
It will be overwritten soon with return value of kzalloc().

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar 92e615ec82 thermal: cpu_cooling: no need to set cpufreq_state to zero
Its already zero, we allocated cpufreq_dev with kzalloc.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar 98d522f056 thermal: cpu_cooling: Pass variable instead of its type to sizeof()
Just following coding guidelines here.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar 07d888d831 thermal: cpu_cooling: Add comment to clarify relation between cooling state and frequency
This wasn't explained well anywhere and should be clearly specified. Lets add a
top level comment for this.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar beca6053fc thermal: cpu_cooling: fix doc comment over struct cpufreq_cooling_device
cooling_cpufreq_lock isn't used to protect this structure and so the comment
over it is outdated. Fix it.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:54 -04:00
Viresh Kumar 728c03c959 thermal: cpu_cooling: random comment fixups
s/give/given

Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:54 -04:00
Eduardo Valentin 0f1be51c35 thermal: cpu_cooling: check for the readiness of cpufreq layer
In this patch, the cpu_cooling code checks for the usability of cpufreq
layer before proceeding with the CPU cooling device registration. The
main reason is: CPU cooling device is not usable if cpufreq cannot
switch frequencies.

Similar checks are spread in thermal drivers. Thus, the advantage now
is to have the check in a single place: cpu cooling device registration.
For this reason, this patch also updates the existing drivers that
depend on CPU cooling to simply propagate the error code of the cpu
cooling registration call. Therefore, in case cpufreq is not ready, the
thermal drivers will still return -EPROBE_DEFER, in an attempt to try
again when cpufreq layer gets ready.

Cc: devicetree@vger.kernel.org
Cc: Grant Likely <grant.likely@linaro.org>
Cc: Kukjin Kim <kgene.kim@samsung.com>
Cc: linux-arm-kernel@lists.infradead.org
Cc: linux-kernel@vger.kernel.org
Cc: linux-pm@vger.kernel.org
Cc: linux-samsung-soc@vger.kernel.org
Cc: Naveen Krishna Chatradhi <ch.naveen@samsung.com>
Cc: Rob Herring <robh+dt@kernel.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:53 -04:00
Yadwinder Singh Brar 2dcd851fe4 thermal: cpu_cooling: Update always cpufreq policy with thermal constraints
Existing code updates cupfreq policy only while executing
cpufreq_apply_cooling() function (i.e. when notify_device != NOTIFY_INVALID).
It doesn't apply constraints when cpufreq policy update happens from any other
place but it should update the cpufreq policy with thermal constraints every
time when there is a cpufreq policy update, to keep state of
cpufreq_cooling_device and max_feq of cpufreq policy in sync. For instance
while resuming cpufreq updates cpufreq_policy and it restores default
policy->usr_policy values irrespective of cooling device's cpufreq_state since
notification gets missed because (notify_device == NOTIFY_INVALID).
Another problem, is that userspace is able to change max_freq irrespective of
cooling device's state, as notification gets missed.

This patch modifies code to maintain a global cpufreq_dev_list and applies
constraints of all matching cooling devices for policy's cpu when there is any
policy update(ends up applying the lowest max_freq among the matching cpu
cooling devices).

This patch also removes redundant check (max_freq > policy->user_policy.max),
as cpufreq framework takes care of user_policy constraints already where ever
required, otherwise its causing an issue while increasing max_freq in normal
scenerio as it restores max_freq with policy->user_policy.max which is old
(smaller) value.

Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-11-20 18:17:11 -04:00
Javi Merino 9746b6e726 thermal: cpu_cooling: fix typo highjack -> hijack
Cc: Eduardo Valentin <eduardo.valentin@ti.com>
Cc: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-07-22 10:12:05 +08:00
Stratos Karafotis 3c84ef3af7 thermal: cpu_cooling: Use cpufreq_for_each_valid_entry macro for iteration
The cpufreq core now supports the cpufreq_for_each_valid_entry macro
helper for iteration over the cpufreq_frequency_table, so use it.

Also remove the redundant !! operator.

It should have no functional changes.

Signed-off-by: Stratos Karafotis <stratosk@semaphore.gr>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2014-04-30 00:06:49 +02:00
Zhang Rui 201531c277 Merge branches 'misc', 'soc', 'soc-eduardo' and 'int3404-thermal' of .git into next 2014-01-02 14:22:28 +08:00
Zhang Rui a116776f7b Thermal cpu cooling: return error if no valid cpu frequency entry
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-01-02 11:59:18 +08:00
Eduardo Valentin 1c9573a40c thermal: fix cpu_cooling max_level behavior
As per Documentation/thermal/sysfs-api.txt, max_level
is an index, not a counter. Thus, in case a CPU has
3 valid frequencies, max_level is expected to be 2, for instance.

The current code makes max_level == number of valid frequencies,
which is bogus. This patch fix the cpu_cooling device by
ranging max_level properly.

Reported-by: Carlos Hernandez <ceh@ti.com>
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-01-02 11:54:14 +08:00
Eduardo Valentin 39d99cff76 thermal: cpu_cooling: introduce of_cpufreq_cooling_register
This patch introduces an API to register cpufreq cooling device
based on device tree node.

The registration via device tree node differs from normal
registration due to the fact that it is needed to fill
the device_node structure in order to be able to match
the cooling devices with trip points.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
2013-12-04 09:33:34 -04:00
Wei Yongjun 73b9bcd76d thermal: cpu_cooling: fix return value check in cpufreq_cooling_register()
In case of error, the function thermal_cooling_device_register() returns
ERR_PTR() and never returns NULL. The NULL test in the return value check
should be replaced with IS_ERR().

Signed-off-by: Wei Yongjun <yongjun_wei@trendmicro.com.cn>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-11-06 13:16:49 +08:00
Eduardo Valentin 50e66c7ed8 drivers: thermal: add check when unregistering cpu cooling
This patch avoids NULL pointer accesses while unregistering
cpu cooling devices, in case a NULL pointer is received.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
2013-09-03 09:10:34 -04:00
Lan Tianyu 044d5c26da Thermal/cpu_cooling: Return directly for the cpu out of allowed_cpus in the cpufreq_thermal_notifier()
cpufreq_thermal_notifier() is to change the cpu's cpufreq in the allowed_cpus mask
when associated thermal-cpufreq cdev's cooling state is changed. It's a cpufreq policy
notifier handler and it will be triggered even if those cpus out of allowed_cpus has
changed freq policy.

cpufreq_thermal_notifier() checks the policy->cpu. If it belongs to allowed_cpus,
change max_freq(default to 0) to the desire cpufreq value and pass 0 and max_freq
to cpufreq_verify_within_limits() as cpufreq scope. But if not, do nothing and
max_freq will remain 0. This will cause the cpufreq scope to become 0~0. This
is not right. This patch is to return directly after finding cpu not belonging
to allowed_cpus.

Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-08-15 15:25:08 +08:00
Shawn Guo 24c7a38172 thermal: cpu_cooling: fix 'descend' check in get_property()
The variable 'descend' is initialized as -1 in function get_property(),
and will never get any chance to be updated by the following code.

	if (freq != CPUFREQ_ENTRY_INVALID && descend != -1)
		descend = !!(freq > table[i].frequency);

This makes function get_property() return the wrong frequency for given
cooling level if the frequency table is sorted in ascending.  Fix it
by correcting the 'descend' check in if-condition to 'descend == -1'.

Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-05-28 14:49:31 +08:00
Eduardo Valentin 5fda7f680a thermal: cpu_cooling: alignment improvements
Improve code readiness by changing alignments so that
they match open parenthesis, like checkpatch.pl --strict
suggests.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-27 09:25:55 +08:00
Eduardo Valentin ef5e2124ec thermal: cpu_cooling: remove checkpatch.pl warning
Simple code style fix.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-27 09:25:51 +08:00
Eduardo Valentin e45a643002 thermal: cpu_cooling: remove trailing blank line
Remove unnecessary blank line.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-27 09:25:47 +08:00
Eduardo Valentin d8892a01b1 thermal: cpu_cooling: align on open parenthesis
Improve code readiness by remove checkpatch.pl warnings
on get_property function.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-27 09:25:43 +08:00
Eduardo Valentin 1b9e352659 thermal: cpu_cooling: standardize comment style
There are at least three patterns for oneline comments in this
file. This patch changes them to one single pattern

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-27 09:25:38 +08:00
Eduardo Valentin 79491e53dc thermal: cpu_cooling: standardize end of function
Just for code readiness, this patch makes all functions
on this file to have a blank line before their returns.
Now, some functions follow this pattern, and others will
not have a blank line. So, this patch makes it a single
pattern.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-27 09:25:32 +08:00
Eduardo Valentin 79d264016a thermal: cpu_cooling: remove trailing white spaces
Remove unnecessary white spaces.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-27 09:25:24 +08:00
Eduardo Valentin 67d0b2a826 thermal: cpu_cooling: remove unused symbols
The list is not needed so far. Thus removing it.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:44 +08:00
Eduardo Valentin 2d9bf71c12 thermal: cpu_cooling: remove not needed curl brackets
Just for style purposes, remove extra curl brackets.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:43 +08:00
Eduardo Valentin 99871a714b thermal: cpu_cooling: use snprintf instead of sprintf
Limit the amount of bytes written to dev_name by
secure writing with snprintf.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:43 +08:00
Eduardo Valentin 135266b4ea thermal: cpu_cooling: update kernel-doc comment for cpufreq_cooling_unregister
Update comments for this exported function.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:42 +08:00
Eduardo Valentin 12cb08ba50 thermal: cpu_cooling: update kernel-doc for cpufreq_cooling_register
Add proper documentation for exported function cpufreq_cooling_register.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:42 +08:00
Eduardo Valentin 56e05fdb6d thermal: cpu_cooling: update documentation for cpufreq_set_cur_state
Update documentation for cpufreq_set_cur_state callback.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:42 +08:00
Eduardo Valentin 3672552dc0 thermal: cpu_cooling: update documentation for cpufreq_get_cur_state
Update documentation for cpufreq_get_cur_state callback.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:41 +08:00
Eduardo Valentin 62c00421b3 thermal: cpu_cooling: update documentation for cpufreq_get_max_state
Update documentation for cpufreq_get_max_state callback.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:41 +08:00
Eduardo Valentin bab3055472 thermal: cpu_cooling: update documentation for cpufreq_thermal_notifier
Update kernel-doc comment and documentation for cpufreq_thermal_notifier.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:40 +08:00
Eduardo Valentin 4b33deb547 thermal: cpu_cooling: update documentation for cpufreq_apply_cooling
Update kernel-doc comments for cpufreq_apply_cooling function.

Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Acked-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2013-04-25 00:34:39 +08:00