P9 DD2 NX workbook (Table 4-36) says DMA controller uses CC=5
internally for translation fault handling. NX reserves CC=250 for
OS to notify user space when NX encounters address translation
failure on the request buffer. Not an issue in earlier releases
as NX does not get faults on kernel addresses.
This patch defines CSB_CC_FAULT_ADDRESS(250) and updates CSB.CC with
this proper error code for user space.
Fixes: c96c4436ab ("powerpc/vas: Update CSB and notify process for fault CRBs")
Signed-off-by: Haren Myneni <haren@linux.ibm.com>
[mpe: Added Fixes tag and fix typo in comment]
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/019fd53e7538c6f8f332d175df74b1815ef5aa8c.camel@linux.ibm.com
Power9 introduced Virtual Accelerator Switchboard (VAS) which allows
userspace to communicate with Nest Accelerator (NX) directly. But
kernel has to establish channel to NX for userspace. This document
describes user space API that application can use to establish
communication channel.
Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.ibm.com>
Signed-off-by: Haren Myneni <haren@linux.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/1587114715.2275.1135.camel@hbabu-laptop