The driver uses the MODULE_ALIAS() macro to export a platform module alias
to allow the module to be autoloaded if the device is registered using the
legacy platform registration mechanism but the driver is always used by OF
only machines so the alias is not needed and should just be removed.
Suggested-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
These platform drivers have a OF device ID table but the OF module
alias information is not created so module autoloading won't work.
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Acked-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Implement the suspend/resume function in order to control rtc's irq_wake flag and handle as wakeup source.
Signed-off-by: Henry Chen <henryc.chen@mediatek.com>
Acked-by: Eddie Huang <eddie.huang@mediatek.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
rtc_sysfs_add_device checks if device can wakeup before creating the
wakealarm file in sysfs. Thus the driver must set wakeup capability
before registering the rtc device.
Signed-off-by: Wei-Ning Huang <wnhuang@google.com>
Acked-by: Eddie Huang <eddie.huang@mediatek.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
On some !ARM 32bits platforms, the following compilation error happens
because of the division on a 64bits value in mtk_rtc_read_time():
drivers/built-in.o: In function `mtk_rtc_read_time':
rtc-mt6397.c:(.text+0x265d13f): undefined reference to `__divdi3'
rtc-mt6397.c:(.text+0x265d150): undefined reference to `__moddi3'
Use div_s64() as done in rtc_time64_to_tm() to solve that.
Reported-by: kbuild test robot <fengguang.wu@intel.com>
Acked-by: Eddie Huang <eddie.huang@mediatek.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>