If chgmod == BATFULL, setting chgena has no effect. Datasheet says we
need to set resume instead but when autoresume is used resume doesn't
work. Clear and set chgena instead.
This enables a user to force charging by re-plugging USB even when the
charger entered Battery Full mode, might be handy before a long trip.
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
After reaching Battery Full condition MBC state machine switches back
into charging mode when the battery voltage falls below 96% of a
battery float voltage. The voltage drop in Li-Ion batteries is
marginal (1-2%) till about 80% of its capacity - which means, after a
BATFULL, charging won't be restarted until 75-80%.
That is a desired behaviour recommended by battery manufacturers,
don't mess with it.
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Implement a new sysfs attribute to allow changing MBC charging limit on
the fly independently of usb current limit. It also gets set
automatically every time usb current limit is changed.
Limiting charging current also prevents violating USB specification in
the case when the whole device is shut down and usb current limit is
reset to the factory default by the pcf50633 state transition.
Signed-off-by: Balaji Rao <balajirrao@openmoko.org>
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This adds an appropriate ac power_supply class and shows usb only when
at the appropriate current limit.
Signed-off-by: Sean McNeil <sean@mcneil.com>
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
The 'pcf50633_mbc_set_status' function is unused, so remove it.
Signed-off-by: Balaji Rao <balajirrao@openmoko.org>
Cc: Andy Green <andy@openmoko.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
The battery charger state machine switches into charging mode when
the battery voltage falls below 96% of a battery float voltage. But
the voltage drop in Li-ion batteries is marginal(1~2 %) till about
80% of its capacity - which means, after a BATFULL, charging won't
be restarted until 80%.
This work_struct function restarts charging at regular intervals to
make sure the battery doesn't discharge too much.
Signed-off-by: Balaji Rao <balajirrao@openmoko.org>
Cc: Andy Green <andy@openmoko.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
container_of(psy, struct pcf50633_mbc, usb); should be
container_of(psy, struct pcf50633_mbc, adapter);
Signed-off-by: Balaji Rao <balajirrao@openmoko.org>
Cc: Andy Green <andy@openmoko.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Signed-off-by: Balaji Rao <balajirrao@openmoko.org>
Cc: Andy Green <andy@openmoko.com>
Cc: David Woodhouse <dwmw2@infradead.org>
Acked-by: Anton Vorontsov <cbouatmailru@gmail.com>
Signed-off-by: Samuel Ortiz <sameo@openedhand.com>