[ALSA] ymfpci: fix SPDIF sample rate information

Modules: YMFPCI driver

Set the (read only) sample rate field in the IEC958 mixer controls to
48 kHz (instead of 44.1 kHz) because that is the rate actually
supported by the hardware.

Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
This commit is contained in:
Clemens Ladisch 2006-01-13 07:41:45 +01:00 committed by Jaroslav Kysela
parent da79e44df4
commit fc80a2027a
1 changed files with 2 additions and 0 deletions

View File

@ -1229,6 +1229,7 @@ static int snd_ymfpci_spdif_default_get(struct snd_kcontrol *kcontrol,
spin_lock_irq(&chip->reg_lock);
ucontrol->value.iec958.status[0] = (chip->spdif_bits >> 0) & 0xff;
ucontrol->value.iec958.status[1] = (chip->spdif_bits >> 8) & 0xff;
ucontrol->value.iec958.status[3] = IEC958_AES3_CON_FS_48000;
spin_unlock_irq(&chip->reg_lock);
return 0;
}
@ -1303,6 +1304,7 @@ static int snd_ymfpci_spdif_stream_get(struct snd_kcontrol *kcontrol,
spin_lock_irq(&chip->reg_lock);
ucontrol->value.iec958.status[0] = (chip->spdif_pcm_bits >> 0) & 0xff;
ucontrol->value.iec958.status[1] = (chip->spdif_pcm_bits >> 8) & 0xff;
ucontrol->value.iec958.status[3] = IEC958_AES3_CON_FS_48000;
spin_unlock_irq(&chip->reg_lock);
return 0;
}