dt-bindings: watchdog: Consolidate SP805 binding docs
Consolidate two SP805 binding documents "arm,sp805.txt" and "sp805-wdt.txt" into "arm,sp805.txt" that matches the naming of the desired compatible string to be used Signed-off-by: Ray Jui <ray.jui@broadcom.com> Reviewed-by: Rob Herring <robh@kernel.org> Reviewed-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
This commit is contained in:
parent
2421cfd55a
commit
fb18d30f86
|
@ -1,17 +1,30 @@
|
|||
ARM AMBA Primecell SP805 Watchdog
|
||||
|
||||
SP805 WDT is a ARM Primecell Peripheral and has a standard-id register that
|
||||
can be used to identify the peripheral type, vendor, and revision.
|
||||
This value can be used for driver matching.
|
||||
|
||||
As SP805 WDT is a primecell IP, it follows the base bindings specified in
|
||||
'arm/primecell.txt'
|
||||
|
||||
Required properties:
|
||||
- compatible: Should be "arm,sp805" & "arm,primecell"
|
||||
- reg: Should contain location and length for watchdog timer register.
|
||||
- interrupts: Should contain the list of watchdog timer interrupts.
|
||||
- clocks: clocks driving the watchdog timer hardware. This list should be 2
|
||||
clocks. With 2 clocks, the order is wdogclk clock, apb_pclk.
|
||||
- compatible: Should be "arm,sp805" & "arm,primecell"
|
||||
- reg: Should contain location and length for watchdog timer register
|
||||
- clocks: Clocks driving the watchdog timer hardware. This list should be
|
||||
2 clocks. With 2 clocks, the order is wdog_clk, apb_pclk
|
||||
wdog_clk can be equal to or be a sub-multiple of the apb_pclk
|
||||
frequency
|
||||
- clock-names: Shall be "wdog_clk" for first clock and "apb_pclk" for the
|
||||
second one
|
||||
|
||||
Optional properties:
|
||||
- interrupts: Should specify WDT interrupt number
|
||||
|
||||
Example:
|
||||
watchdog@66090000 {
|
||||
compatible = "arm,sp805", "arm,primecell";
|
||||
reg = <0x66090000 0x1000>;
|
||||
interrupts = <GIC_SPI 406 IRQ_TYPE_LEVEL_HIGH>;
|
||||
clocks = <&apb_pclk>,<&apb_pclk>;
|
||||
clock-names = "wdogclk", "apb_pclk";
|
||||
clocks = <&wdt_clk>, <&apb_pclk>;
|
||||
clock-names = "wdog_clk", "apb_pclk";
|
||||
};
|
||||
|
|
|
@ -1,31 +0,0 @@
|
|||
* ARM SP805 Watchdog Timer (WDT) Controller
|
||||
|
||||
SP805 WDT is a ARM Primecell Peripheral and has a standard-id register that
|
||||
can be used to identify the peripheral type, vendor, and revision.
|
||||
This value can be used for driver matching.
|
||||
|
||||
As SP805 WDT is a primecell IP, it follows the base bindings specified in
|
||||
'arm/primecell.txt'
|
||||
|
||||
Required properties:
|
||||
- compatible : Should be "arm,sp805-wdt", "arm,primecell"
|
||||
- reg : Base address and size of the watchdog timer registers.
|
||||
- clocks : From common clock binding.
|
||||
First clock is PCLK and the second is WDOGCLK.
|
||||
WDOGCLK can be equal to or be a sub-multiple of the PCLK frequency.
|
||||
- clock-names : From common clock binding.
|
||||
Shall be "apb_pclk" for first clock and "wdog_clk" for the
|
||||
second one.
|
||||
|
||||
Optional properties:
|
||||
- interrupts : Should specify WDT interrupt number.
|
||||
|
||||
Examples:
|
||||
|
||||
cluster1_core0_watchdog: wdt@c000000 {
|
||||
compatible = "arm,sp805-wdt", "arm,primecell";
|
||||
reg = <0x0 0xc000000 0x0 0x1000>;
|
||||
clocks = <&clockgen 4 3>, <&clockgen 4 3>;
|
||||
clock-names = "apb_pclk", "wdog_clk";
|
||||
};
|
||||
|
Loading…