[media] smiapp: Take mutex during PLL update in sensor initialisation
The mutex does not serialise anything in this case but avoids a lockdep warning from the control framework. Cc: stable@vger.kernel.org Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com> Acked-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com> Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
This commit is contained in:
parent
d6d41ba1cb
commit
f85698cd29
|
@ -2677,7 +2677,9 @@ static int smiapp_registered(struct v4l2_subdev *subdev)
|
|||
pll->flags |= SMIAPP_PLL_FLAG_NO_OP_CLOCKS;
|
||||
pll->scale_n = sensor->limits[SMIAPP_LIMIT_SCALER_N_MIN];
|
||||
|
||||
mutex_lock(&sensor->mutex);
|
||||
rval = smiapp_update_mode(sensor);
|
||||
mutex_unlock(&sensor->mutex);
|
||||
if (rval) {
|
||||
dev_err(&client->dev, "update mode failed\n");
|
||||
goto out_nvm_release;
|
||||
|
|
Loading…