PM / devfreq: event: Remove incorrect property in exynos-ppmu DT binding
The exynos-ppmu driver is only a clock consumer and not a clock provider but its Device Tree binding listed #clock-cells as an optional property. Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com> Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com> Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
This commit is contained in:
parent
64291f7db5
commit
f47ff87f79
|
@ -17,7 +17,6 @@ Required properties:
|
|||
Optional properties:
|
||||
- clock-names : the name of clock used by the PPMU, "ppmu"
|
||||
- clocks : phandles for clock specified in "clock-names" property
|
||||
- #clock-cells: should be 1.
|
||||
|
||||
Example1 : PPMU nodes in exynos3250.dtsi are listed below.
|
||||
|
||||
|
|