PM / devfreq: exynos-ppmu: Fix refcount leak in of_get_devfreq_events
of_get_child_by_name() returns a node pointer with refcount
incremented, we should use of_node_put() on it when done.
This function only calls of_node_put() in normal path,
missing it in error paths.
Add missing of_node_put() to avoid refcount leak.
Fixes: f262f28c14
("PM / devfreq: event: Add devfreq_event class")
Signed-off-by: Miaoqian Lin <linmq006@gmail.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
This commit is contained in:
parent
20e6c3cc90
commit
f44b799603
|
@ -519,15 +519,19 @@ static int of_get_devfreq_events(struct device_node *np,
|
|||
|
||||
count = of_get_child_count(events_np);
|
||||
desc = devm_kcalloc(dev, count, sizeof(*desc), GFP_KERNEL);
|
||||
if (!desc)
|
||||
if (!desc) {
|
||||
of_node_put(events_np);
|
||||
return -ENOMEM;
|
||||
}
|
||||
info->num_events = count;
|
||||
|
||||
of_id = of_match_device(exynos_ppmu_id_match, dev);
|
||||
if (of_id)
|
||||
info->ppmu_type = (enum exynos_ppmu_type)of_id->data;
|
||||
else
|
||||
else {
|
||||
of_node_put(events_np);
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
j = 0;
|
||||
for_each_child_of_node(events_np, node) {
|
||||
|
|