mfd: wm8994: Reset device during probe
Ensure that the device is in a known good state. This should have little practical impact as the runtime PM will reset the device shortly after probe but it's neater. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
This commit is contained in:
parent
1ee5d8c85a
commit
f3799e9372
|
@ -652,6 +652,17 @@ static int wm8994_device_init(struct wm8994 *wm8994, int irq)
|
|||
return ret;
|
||||
}
|
||||
|
||||
/* Explicitly put the device into reset in case regulators
|
||||
* don't get disabled in order to ensure we know the device
|
||||
* state.
|
||||
*/
|
||||
ret = wm8994_reg_write(wm8994, WM8994_SOFTWARE_RESET,
|
||||
wm8994_reg_read(wm8994, WM8994_SOFTWARE_RESET));
|
||||
if (ret != 0) {
|
||||
dev_err(wm8994->dev, "Failed to reset device: %d\n", ret);
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (regmap_patch) {
|
||||
ret = regmap_register_patch(wm8994->regmap, regmap_patch,
|
||||
patch_regs);
|
||||
|
|
Loading…