iio: pressure: st_pressure: fix drdy configuration for LPS22HB and LPS25H
Remove int2 configuration parameter for LPS22HB and LPS25H since these devices export just int1 as data-ready line Fixes:931878405b
(iio:pressure: Add support for LPS25H pressure sensor) Fixes:e039e2f5b4
(iio:st_pressure:initial lps22hb sensor support) Signed-off-by: Lorenzo Bianconi <lorenzo.bianconi@st.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
ce0d376140
commit
ef0bc2e839
|
@ -390,7 +390,7 @@ static const struct st_sensor_settings st_press_sensors_settings[] = {
|
|||
.drdy_irq = {
|
||||
.addr = 0x23,
|
||||
.mask_int1 = 0x01,
|
||||
.mask_int2 = 0x10,
|
||||
.mask_int2 = 0x00,
|
||||
.addr_ihl = 0x22,
|
||||
.mask_ihl = 0x80,
|
||||
.addr_od = 0x22,
|
||||
|
@ -449,7 +449,7 @@ static const struct st_sensor_settings st_press_sensors_settings[] = {
|
|||
.drdy_irq = {
|
||||
.addr = 0x12,
|
||||
.mask_int1 = 0x04,
|
||||
.mask_int2 = 0x08,
|
||||
.mask_int2 = 0x00,
|
||||
.addr_ihl = 0x12,
|
||||
.mask_ihl = 0x80,
|
||||
.addr_od = 0x12,
|
||||
|
|