ACPI / thermal: Fix wrong variable usage in debug statement

A debug statement in acpi_thermal_trips_update() uses a wrong trip
point (tz->trips.critical instead of tz->trips.hot) to get the
temperature value from.  Fix that.

Signed-off-by: Zhihui Zhang <zzhsuny@gmail.com>
[rjw: Subject and changelog]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
This commit is contained in:
Zhihui Zhang 2014-03-29 09:25:47 -04:00 committed by Rafael J. Wysocki
parent 70f6c08757
commit ee17fdf24b
1 changed files with 1 additions and 1 deletions

View File

@ -344,7 +344,7 @@ static int acpi_thermal_trips_update(struct acpi_thermal *tz, int flag)
tz->trips.hot.flags.valid = 1;
ACPI_DEBUG_PRINT((ACPI_DB_INFO,
"Found hot threshold [%lu]\n",
tz->trips.critical.temperature));
tz->trips.hot.temperature));
}
}