platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table
The CONNECT X300 uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this
device to the critical systems list.
Tested on CONNECT X300.
Fixes: 648e921888
("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
This commit is contained in:
parent
133b2acee3
commit
e8796c6c69
|
@ -429,6 +429,14 @@ static const struct dmi_system_id critclk_systems[] = {
|
|||
DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
|
||||
},
|
||||
},
|
||||
{
|
||||
.ident = "CONNECT X300",
|
||||
.matches = {
|
||||
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
|
||||
DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
|
||||
},
|
||||
},
|
||||
|
||||
{ /*sentinel*/ }
|
||||
};
|
||||
|
||||
|
|
Loading…