regulator: axp20x: Use of_match name as default regulator name

Originally the helper macros used uppercase regulator names, which
are primarily used to expand to the regulator ID enum, as the default
names. This is aestheticly unpleasent.

Since the of_match bits are the same, just lowercase, use that as the
default names instead.

Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Chen-Yu Tsai 2016-02-15 18:31:22 +08:00 committed by Mark Brown
parent 13d57e6435
commit e0bbb38c2f
1 changed files with 5 additions and 5 deletions

View File

@ -39,7 +39,7 @@
#define AXP_DESC_IO(_family, _id, _match, _supply, _min, _max, _step, _vreg, \
_vmask, _ereg, _emask, _enable_val, _disable_val) \
[_family##_##_id] = { \
.name = #_id, \
.name = (_match), \
.supply_name = (_supply), \
.of_match = of_match_ptr(_match), \
.regulators_node = of_match_ptr("regulators"), \
@ -61,7 +61,7 @@
#define AXP_DESC(_family, _id, _match, _supply, _min, _max, _step, _vreg, \
_vmask, _ereg, _emask) \
[_family##_##_id] = { \
.name = #_id, \
.name = (_match), \
.supply_name = (_supply), \
.of_match = of_match_ptr(_match), \
.regulators_node = of_match_ptr("regulators"), \
@ -80,7 +80,7 @@
#define AXP_DESC_SW(_family, _id, _match, _supply, _ereg, _emask) \
[_family##_##_id] = { \
.name = #_id, \
.name = (_match), \
.supply_name = (_supply), \
.of_match = of_match_ptr(_match), \
.regulators_node = of_match_ptr("regulators"), \
@ -94,7 +94,7 @@
#define AXP_DESC_FIXED(_family, _id, _match, _supply, _volt) \
[_family##_##_id] = { \
.name = #_id, \
.name = (_match), \
.supply_name = (_supply), \
.of_match = of_match_ptr(_match), \
.regulators_node = of_match_ptr("regulators"), \
@ -109,7 +109,7 @@
#define AXP_DESC_RANGES(_family, _id, _match, _supply, _ranges, _n_voltages, \
_vreg, _vmask, _ereg, _emask) \
[_family##_##_id] = { \
.name = #_id, \
.name = (_match), \
.supply_name = (_supply), \
.of_match = of_match_ptr(_match), \
.regulators_node = of_match_ptr("regulators"), \